APC SMART
UPS 1400 Rackmount 2U 1400VA 950W SU1400RM2U Refurbished with Brand New
Batteries
At
ExcessUPS we specialize in APC power protection products. We professionally
refurbish and thoroughly test each and every APC UPS. Every refurbished APC
battery backup UPS has brand new high quality batteries installed that meet or
exceed APC’s specifications. We install only high quality long life batteries in
every uninterruptible power supply, providing reliable and dependable power
protection.
APC Smart-UPS 1400 Rack mount 2U SU1400RM2U
User's Manual
A serial
communications cable (940-0024C) is included with this item. It will give
you greater control and customization options for this UPS. APC's PowerChute
software, available free of charge on APC's website, provides extended features
and abilities to enhance the effectiveness and usefulness of this
UPS.
APC PowerChute Business Edition Basic v
7.0.5
Output:
|
Output Power Capacity
|
950 Watts / 1400
VA |
|
Max Configurable
Power |
950 Watts / 1400 VA
|
|
Nominal Output Voltage
|
120V |
|
Output Voltage
Distortion |
Less than 5% at full
load |
|
Output Frequency (sync to
mains) |
47 - 53 Hz for 50 Hz nominal,57 -
63 Hz for 60 Hz nominal |
|
Crest Factor |
up to 5 : 1 |
|
Waveform Type |
Sine wave |
|
Output Connections |
(6) NEMA 5-15R  |
|
|
|
Input
Nominal Input
Voltage |
120V |
Input
Frequency |
50/60 Hz +/- 3
Hz (auto sensing) |
Input
Connections |
NEMA
5-15P  |
Cord
Length |
2.44 meters |
Input voltage
range for main operations |
82 -
144V |
Input voltage
adjustable range for mains operation |
75 -
154V |
Batteries & Runtime
Battery
Type |
Maintenance-free
sealed Lead-Acid battery with suspended electrolyte:
leakproof |
Typical
recharge time |
3 hour(s) |
Replacement
battery cartridge |
|
Typical Backup
Time at Half Load |
27.9 minutes
(475 Watts) |
|
Typical Backup Time at Full
Load |
7.8 minutes
(950 Watts) |
|
Runtime Chart |
Smart-UPS |
Communications & Management
|
Interface Port(s) |
DB-9
RS-232,SmartSlot |
|
Available SmartSlot™ Interface
Quantity |
1 |
|
Control panel
|
LED status display with load and
battery bar-graphs and On Line : On Battery : Replace Battery : and Overload
Indicators
Audible Alarm
Alarm when on battery : distinctive
low battery alarm : configurable delays
Emergency Power Off (EPO)
Optional
|
Surge Protection and Filtering
|
Surge energy rating |
459 Joules |
|
Filtering |
Full time multi-pole noise
filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL
1449 |
Physical
|
Maximum Height |
89.00 mm |
|
Maximum Width |
483.00 mm |
|
Maximum depth |
457.00 mm |
|
Rack Height |
2U |
Environmental
|
Operating
Environment |
0 - 40 °C |
|
Operating Relative Humidity
|
0 - 95% |
|
Operating Elevation |
0-3000 meters |
|
Storage Temperature |
-15 -
45 °C |
|
Storage Relative
Humidity |
0 - 95% |
|
Storage Elevation |
0-15000 meters
|
|
Online Thermal
Dissipation |
171 BTU/hr |
|