APC SMART-UPS 2200 Rackmount 2U
2200VA 1980W SUA2200RM2U Refurbished with New
Batteries
At
ExcessUPS we specialize in APC power protection products. We professionally
refurbish and thoroughly test each and every APC UPS. Every refurbished APC
battery backup UPS has brand new high quality batteries installed that meet or
exceed APC’s specifications. We install only high quality long life batteries in
every uninterruptible power supply, providing reliable and dependable power
protection.
APC Smart-UPS 2200 SUA2200RM2U User's
Manual
A serial
communications cable (940-0024C) is included with this item. It will give
you greater control and customization options for this UPS. APC's PowerChute
software, available free of charge on APC's website, provides extended features
and abilities to enhance the effectiveness and usefulness of this
UPS.
APC PowerChute Business Edition Basic v
7.0.5
Output
|
Output Power Capacity
|
1980 Watts / 2200
VA |
|
Max Configurable Power
|
1980 Watts / 2200 VA
|
|
Nominal Output
Voltag |
120V |
|
Efficiency at Full Load
|
95% |
|
Output Voltage Distortion
|
47 - 53 Hz for 50 Hz nominal,57 - 63
Hz for 60 Hz nominal |
|
Crest Factor |
up to 5 : 1 |
|
Waveform Type |
Sine wave |
|
Output Connections
(6) NEMA 5-15R |
 |
|
(2) NEMA 5-20R |
|
Input
|
Nominal Input Voltage
|
120V |
|
Input Frequency |
50/60 Hz +/- 3 Hz (auto
sensing) |
|
Input Connections |
NEMA 5-20P |
|
Cord Length |
2.44 meters
|
|
Input voltage range for main
operations |
82 - 144V |
|
Input voltage adjustable range for
mains operation |
75 - 154V
|
Batteries &
Runtime
|
Battery Type |
Maintenance-free sealed Lead-Acid
battery with suspended electrolyte : leakproof |
|
Typical recharge
time |
3 hour(s) |
|
Replacement battery
cartridge |
RBC43 |
|
Typical Backup Time at Half
Load |
15.7 minutes (990
Watts) |
|
Typical Backup Time at Full
Load |
5.2 minutes (1980
Watts) |
|
Runtime Chart |
Smart-UPS |
Communications &
Management
|
Interface Port(s) |
DB-9
RS-232,SmartSlot,USB |
|
Available SmartSlot™ Interface
Quantity |
1 |
|
Control panel |
LED status display with load and
battery bar-graphs and On Line : On Battery : Replace Battery : and Overload
Indicators |
|
Audible Alarm |
Alarm when on battery : distinctive
low battery alarm : configurable delays |
|
Emergency Power Off
(EPO) |
Yes |
Surge Protection and
Filtering
|
Surge energy rating |
480 Joules |
|
Filtering |
Full time multi-pole noise filtering
: 0.3% IEEE surge let-through : zero clamping response time : meets UL
1449 |
|