Description
Details
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 3000VA 2880W, RM, 4U, 120V
Condition: New batteries, refurbished UPS
Part Number: SMART3000CRMXL
Maximum output: 2880W / 3000VA
Typical backup time at half load:19 minutes (1440 Watts)
Typical backup time at full load: 7.5 minutes (2880 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 3000VA 2880W RM 120V SMART3000CRMXL Manual
SMART3000CRMXL - Tripp Lite SmartPro 3000VA Specifications:
Input:
Rated input current (Maximum Load) |
24A (L5-30P input), 30A (hardwire) |
||||
Nominal Input Voltage(s) Supported |
120V AC |
||||
UPS Input Connection Type |
|
||||
UPS Input Cord Length (ft.) |
10 |
||||
UPS Input Cord Length (m) |
3.1 |
||||
Recommended Electrical Service |
120V 30A |
||||
Voltage Compatibility (VAC) |
120V |
||||
Input Phase |
Single-Phase |
Output:
Output Volt Amp Capacity (VA) |
3000 |
||||
Output Capacity (kVA) |
3.00 |
||||
Output Watt Capacity (Watts) |
2880 |
||||
Output kW Capacity (kW) |
2.88 |
||||
Output Capacity Details |
Maximum output increases to 3600W when used with hardwire input |
||||
Power Factor |
.96 |
||||
Nominal Voltage Details |
120v nominal output in battery mode |
||||
Frequency Compatibility |
60 Hz |
||||
Output Voltage Regulation (Line Mode) |
-18%, +8% |
||||
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||||
Load Management Receptacles |
Three switchable single-outlet 5-15/20R load banks |
||||
Output Circuit Breakers |
20A (x2) - each 20A breaker protects 4 5-15/20R outlets / 30A breaker protects L5-30R |
||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
||||
Output Receptacles |
|
||||
Individually Controllable Load Banks |
Yes |
Battery:
Battery Type |
Valve Regulated Lead Acid (VRLA) |
Full Load Runtime (min.) |
7.5 min. (2880w) |
Half Load Runtime (min.) |
19 min. (1440w) |
Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
Expandable Runtime |
Yes |
External Battery Pack Compatibility |
BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27- 2US (multi-pack compatible) |
DC System Voltage (VDC) |
48 |
Battery Recharge Rate (Included Batteries) |
Less than 7.2 hours from 10% to 90% (typical, full load discharge) |
Battery Access |
Battery access door allows hot swap battery replacement without powering connected equipment off |
Internal UPS Replacement Battery Cartridge |
RBC94-2U (quantity 2) |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
Voltage Regulation Description |
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 83V and overvoltages to 145V |
Overvoltage Correction |
Input voltages between 127 and 145V AC are reduced by 12% |
Undervoltage Correction |
Input voltages between 96 and 108 are boosted by 12% |
Severe Undervoltage Correction |
Input voltages between 83 and 95 are boosted by 24% |
User Interface, Alerts & Controls:
Switches |
Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions. Back panel includes battery charge level switch for internal or external battery configurations |
Audible Alarm |
3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps) and low battery (continuous tone) |
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Surge / Noise Suppression:
UPS AC Suppression Joule Rating |
570 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Primary Form Factor |
Rackmount
|
Cooling Method |
Fan
|
Included Mounting Accessory Description |
Included 2POSTRMKITWM mounting accessory enables 2-post rackmount installation
|
Installation Form Factors Supported with Included Accessories |
2 post 19 inch rackmount
|
Installation Form Factors Supported with Optional Accessories |
4 post rackmount full-depth ( 4POSTRAILKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2- 9USTAND )
|
Minimum Required Rack Depth with External Battery Pack (cm) |
64
|
Minimum Required Rack Depth with External Battery Pack (in.) |
25
|
Minimum Required Rack Depth without External Battery Pack (cm) |
58
|
Minimum Required Rack Depth without External Battery Pack (in.) |
22.8
|
Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm) |
Primary UPS Depth (mm) |
452 |
Primary UPS Height (mm) |
175 |
Primary UPS Width (mm) |
439 |
Rack Height |
4U |
Shipping Dimensions (hwd / cm) |
33.02 x 59.69 x 57.15 |
Shipping Dimensions (hwd / in.) |
13.00 x 23.50 x 22.50 |
Shipping Weight (kg) |
58.29 |
Shipping Weight (lbs.) |
128.50 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
17.50 x 43.94 x 45.21 |
UPS Power Module Dimensions (hwd, in.) |
6.89 x 17.30 x 17.80 |
UPS Power Module Weight (kg) |
46.27 |
UPS Power Module Weight (lbs.) |
102 |
Environmental:
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0-95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
539 |
Battery Mode BTU / Hr. (Full Load) |
2159 |
Audible Noise |
45 dBA maximum, front side 1m |
Communications:
Network Management Cards |
SNMPWEBCARD; WEBCARDLX ; RELAYIOCARD |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Includes RJ11 EPO (emergency power off) port and interconnection cable |
SNMP Compatibility |
Compatible with Tripp Lite UPS management card options WEBCARDLX , SNMPWEBCARD and RELAYIOCARD |
Network Management Card Description |
Network management card optional |
Communications Interface |
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 120V AC |
Output (VA) | 3000VA |
Output Voltage | 120V AC |
PDU Total Outlets | No |