1-866-311-1945 sales@excessups.com

United States United States [change]

Tripp Lite SmartPro 2.2KVA UPS SMART2200CRMXL

SMART2200CRMXL Refurbished SmartPro UPS
2.2kVA 1900W Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 4U Reduced Depth, USB, RS232, EPO, 120V
Refurbished with New Batteries
2.2kVA / 2200VA / 1900W line interactive 4U rack/tower UPS, Sine Wave
120V output, Corrects brownouts and overvoltages from 83V to 145V
0.86 Power Factor, Front panel status LEDs
Extended runtime options up to 1900W
2 post mounting accessories, reduced depth housing
97% line-mode efficiency, 3 switched load banks
USB, RS232, EPO and slot for SNMPWEBCARD option
120V NEMA 5-20P input, 4 NEMA 5-15R & 4 NEMA 5-15/20R outlets

Availability: In stock

$649.99
Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model:
 SMART2200CRMXL SmartPro UPS 2.2kVA 1900W Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 4U Reduced Depth, USB, RS232, EPO, 120V
Condition: Refurbished with New Batteries
Part Number: SMART2200CRMXL
Warranty: 1 Year Full Replacement Warranty, additional warranty available

 

SMART2200CRMXL Specifications:

OUTPUT

Output Volt Amp Capacity (VA)

2200

Output kVA capacity (kVA)

2.2

Output Watt Capacity (watts)

1900

Output kW capacity

1.9

Output power factor

0.9

Nominal Output Voltage(s) Supported

120V

Frequency compatibility

60 Hz

Output voltage regulation (line mode)

-18%, +8%

Output voltage regulation (Battery mode)

+/- 5%

Built-in UPS output receptacles

4 5-15R outlet(s); 4 5-15/20R outlet(s)

Built-in controllable switched load banks

Three switchable single-outlet 5-15R load banks

Output AC waveform (AC mode)

Sine wave

Output AC waveform (battery mode)

Pure Sine wave


INPUT

Rated input current (at maximum load)

16A

Nominal Input Voltage(s) Supported

120V AC

UPS input connection type

5-20P

Input circuit breaker

20A

UPS Input cord length (ft.)

10

UPS Input cord length (m)

3

Recommended Electrical Service

20A 120V

Phase

Single-Phase


BATTERY

Full load runtime (minutes)

11 min. (1900w)

Half load runtime (minutes)

28 min. (950w)

Expandable battery runtime

Extended runtime supported via optional external battery packs

External battery pack compatibility

BP48V24-2U (limit 1); BP48V48RT4U (multi-pack compatible); BP48V27-2US (multi-pack compatible)

DC system voltage (VDC)

48

Battery recharge rate (included batteries)

Less than 3.6 hours from 10% to 90%

Replacement battery cartridge (internal UPS battery replacement)

RBC94-2U (quantity 2)

Battery Access

Front panel battery access door

Battery replacement description

Hot-swappable, user replaceable batteries


VOLTAGE REGULATION

Voltage regulation description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145

Overvoltage correction

Input voltages between 127 and 145 are reduced by 12%

Undervoltage correction

Input voltages between 96 and 108 are boosted by 12%

Severe undervoltage correction

Input voltages between 83 and 95 are boosted by 24%


LEDS ALARMS & SWITCHES

LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

Alarms

Audible alarm indicates power-failure, overload and low-battery conditions

Alarm cancel operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings


SURGE / NOISE SUPPRESSION

UPS AC suppression joule rating

570

UPS AC suppression response time

Instantaneous

EMI / RFI AC noise suppression

Yes


PHYSICAL

Installation form factors supported with included accessories

2 post 19 inch rackmount

Installation form factors supported with optional accessories

4 post rackmount (4POSTRAILKIT); Tower (2-9USTAND)

Primary form factor

Rackmount

UPS / Power Module dimensions in primary form factor (height x width x depth / inches)

6.89 x 17.3 x 17.8

UPS / Power Module dimensions in primary form factor (height x width x depth / cm)

17.5 x 43.9 x 45.2

Rack Height

4U

Secondary form factor

Tower (requires 2-9USTAND)

UPS / Power Module weight (lbs)

100.3

UPS / Power Module weight (kg)

45.5

UPS Shipping dimensions (height x width x depth / inches)

12.8 x 23.3 x 22.8

UPS Shipping dimensions (height x width x depth / cm)

32.4 x 59.1 x 57.8

Shipping weight (lbs)

128.9

Shipping weight (kg)

58.5

Cooling method

Fan

UPS housing material

Steel


ENVIRONMENTAL

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr. (full load)

242


COMMUNICATIONS

Communications interface

USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network monitoring port description

Supports detailed monitoring of UPS and site power conditions

PowerAlert software

Included

Communications cable

USB and DB9 cabling included

WatchDog compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications


LINE / BATTERY TRANSFER

Transfer time

5 milliseconds

Low voltage transfer to battery power (setpoint)

83

High voltage transfer to battery power (setpoint)

145


SPECIAL FEATURES

Cold Start (startup in battery mode during a power failure)

Cold-start operation supported

High availability UPS features

Hot swappable batteries


CERTIFICATIONS

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)

 

Additional Info

Additional Info

Input No
Output(VA) No
Type No
Output Voltage No