Call toll free: 1-866-311-1945 | sales@excessups.com
Your Region:

Tripp Lite SmartOnline 2200VA 1600W RM 2U 120V SU2200RTXL2UA - Refurbished

Tripp Lite SmartOnline 2200VA 1600W RM 2U
Model: SU2200RTXL2UA
Input: NEMA 5-20P (120V - 20A)
Output: (6) NEMA 5-15/20R, (1) NEMA L5-20R
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
$499.99
Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 2200VA 1600W, RM, 2U, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SU2200RTXL2UA

Maximum output: 1600W / 2200VA
Typical backup time
at half load: 14 minutes (800 Watts)
Typical backup time
at full load: 4.5 minutes (1600 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 2200VA 1600W RM 120V SU2200RTXL2UA Manual


SU2200RTXL2UA - Tripp Lite SmartOnline 2200VA Specifications:

Input:

Rated input current (Maximum Load)

16A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-20P

Input Circuit Breakers

30A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

UPS Input Cord Length Details

Built-in

Recommended Electrical Service

20A 120V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

2200

Output Capacity (kVA)

2.2

Output Watt Capacity (Watts)

1600

Output kW Capacity (kW)

1.6

Output Capacity Details

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)

Power Factor

0.7

Crest Factor

3:1

Nominal Voltage Details

120V sinusoidal in line mode and 120V PWM in battery mode

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Two switchable three-outlet 5-15/20R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V

Output Receptacles

(6) NEMA 5-15/20R

(1) NEMA L5-20R

Individually Controllable Load Banks

Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

4.5 min. (1600w)

Half Load Runtime (min.)

14 min. (800w)

Expandable Runtime Description

 BP48V24-2U  (limit 2 w/  48VDCSPLITTER )

External Battery Pack Compatibility

BP48V24-2U  (limit 1);  BP48V60RT-3U  (multi-pack compatible);  BP48V27- 2US  (multi-pack compatible)

DC System Voltage (VDC)

48

Battery Recharge Rate (Included Batteries)

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

 RBC94-2U 

Battery Replacement Description

Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioningf

Overvoltage Correction

2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 80

Severe Undervoltage Correction

2% output voltage regulation during undervoltages to 65 (under 70% load only)


User Interface, Alerts & Controls:

Switches

2 switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

LED Indicators

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Included Mounting Accessory Description

Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2- 9USTAND ); Wallmount ( 2POSTRMKITWM )

Minimum Required Rack Depth with External Battery Pack (cm)

66

Minimum Required Rack Depth with External Battery Pack (in.)

26

Minimum Required Rack Depth without External Battery Pack (cm)

61

Minimum Required Rack Depth without External Battery Pack (in.)

24

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support

Primary UPS Depth (mm)

483

Primary UPS Height (mm)

89

Primary UPS Width (mm)

445

Rack Height

2U

Shipping Dimensions (hwd / cm)

23.11 x 51.05 x 59.18

Shipping Dimensions (hwd / in.)

9.10 x 20.10 x 23.30

Shipping Weight (kg)

28.12

Shipping Weight (lbs.)

62.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

8.89 x 44.45 x 48.26

UPS Power Module Dimensions (hwd, in.)

3.5 x 17.5 x 19

UPS Power Module Weight (kg)

21.50

UPS Power Module Weight (lbs.)

47.4


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

816

AC Economy Mode BTU / Hr. (Full Load)

169

Battery Mode BTU / Hr. (Full Load)

889

AC Economy Mode Efficiency Rating (100% Load)

94%

Audible Noise

< 45dB at 1m


Communication:

Network Management Cards

SNMPWEBCARD; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 2200VA
Output Voltage 120V AC
PDU Total Outlets No

You may also be interested in