Call toll free: 1-866-311-1945 | sales@excessups.com
Your Region:

Tripp Lite SmartPro LCD 1500VA 900W 120V SMART1500LCDT - Refurbished

Tripp Lite OmniSmart LCD 1500VA 900W
Model: SMART1500LCDT
Input: NEMA 5-15P (120V - 15A)
Output: (10) NEMA 5-15R
Line-Interactive UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
$179.99
Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS LCD 1500VA 900W, Tower, 120V, 15A
Condition:
New batteries, refurbished UPS
Part Number:
SMART1500LCDT

Maximum output: 900W / 1500VA
Typical backup time
at half load: 10 minutes (450 Watts)
Typical backup time
at full load: 4 minutes (900 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro LCD 1500VA 900W Tower 120V SMART1500LCDT Manual


SMART1500LCDT - Tripp Lite SmartPro LCD 1500VA Specifications:

Input:

Rated input current (Maximum Load)

12A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-15P

Input Circuit Breakers

20A

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

900

Power Factor

0.8

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Automatic frequency selection

Output Voltage Regulation (Line Mode)

120V (+9% / -12%)

Output Voltage Regulation (Battery Mode)

120V (±10%)

UPS Output Receptacles (Surge Suppression Only)

5 UPS outlets, 5 surge-only outlets

Load Management Receptacles

Two switchable single-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

PWM sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(10) NEMA 5-15R

Individually Controllable Load Banks

No


Battery:

Half Load Runtime (min.)

10 minutes (450 watts)

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries) 

Less than 8 hours from 10% to 90%

Internal UPS Replacement Battery Cartridge

RBC51  (requires 2) 

Expandable Runtime

No


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150

Overvoltage Correction

Input voltages between 129 and 147 are reduced by 15%

Undervoltage Correction

Input voltages between 92 and 108 are boosted by 18%


User Interface, Alerts & Controls:

Front Panel LCD Display

LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status,
Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes

Switches

Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates power-failure and low-battery conditions


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

650

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet; Coax jacks (1 set)

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Primary Form Factor

Tower

Primary UPS Depth (mm)

391

Primary UPS Height (mm)

203

Primary UPS Width (mm)

146

Shipping Dimensions (hwd / in.)

11.10 x 9.00 x 19.30

Shipping Weight (kg)

12.70

Shipping Weight (lbs.)

28.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

20.32 x 14.60 x 39.12

UPS Power Module Dimensions (hwd, in.)

8 x 5.75 x 15.4

UPS Power Module Weight (kg)

12.25

UPS Power Module Weight (lbs.)

27

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

119

Battery Mode BTU / Hr. (Full Load)

867

AC Mode Efficiency Rating (100% Load)

95%


Communications:

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

For local monitoring via the UPS’s built-in USB port, download PowerAlert Local software at
http://www.tripplite.com/poweralert

Communications Cable

USB / Not included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 1500VA
Output Voltage 120V AC
PDU Total Outlets No