Description
Details
Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 2200VA 1600W, Tower, 20A, 120V
Condition: New batteries, refurbished UPS
Part Number: SU2200XLA
Maximum output: 1600W / 2200VA
Typical backup time at half load: 14 minutes (800 Watts)
Typical backup time at full load: 4.5 minutes (1600 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 2200VA 1600W Tower 120V SU2200XLA Manual
SU2200XLA - Tripp Lite SmartOnline 2200VA Specifications:
Output:
Output Volt Amp Capacity (VA) |
2200 |
||||
Output kVA Capacity (kVA) |
2.2 |
||||
Output Watt Capacity (Watts) |
1600 |
||||
Output kW Capacity (kW) |
1.6 |
||||
Power Factor |
0.7 |
||||
Crest Factor |
3:1 |
||||
Nominal Voltage Details |
120V default |
||||
Frequency Compatibility |
50 / 60 Hz |
||||
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
||||
Output Voltage Regulation (Line Mode) |
+/- 2% |
||||
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||||
Load Management Receptacles |
Two switchable three-outlet 5-15/20R load banks |
||||
Output AC Waveform (AC Mode) |
Sine wave |
||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
Output Capacity Details |
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
||||
Nominal Output Voltage(s) Supported |
110V; 120V |
||||
Output Receptacles |
|
||||
Individually Controllable Load Banks |
Yes |
Input:
Rated input current (Maximum Load) |
16A (120V), 17.6A (110V) |
||
Nominal Input Voltage(s) Supported |
110V AC; 120V AC |
||
UPS Input Connection Type |
|
||
Input Circuit Breakers |
30A |
||
UPS Input Cord Length (ft.) |
10 |
||
UPS Input Cord Length (m) |
3.1 |
||
Recommended Electrical Service |
20A 120V |
||
Input Phase |
Single-Phase |
Battery:
Full Load Runtime (min.) |
4.5 min. (1600w) |
Half Load Runtime (min.) |
14 min. (800w) |
Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
External Battery Pack Compatibility |
BP48V27-2US (multi-pack compatible); BP48V60RT-3U (multi-pack compatible) |
DC System Voltage (VDC) |
48 |
Battery Recharge Rate (Included Batteries) |
Less than 6 hours to 80% |
Internal UPS Replacement Battery Cartridge |
RBC48-SUTWR |
Battery Access |
Battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
Yes |
Voltage Regulation:
Voltage Regulation Description |
Online, double-conversion power conditioning |
Overvoltage Correction |
2% output voltage regulation during overvoltages to 150 |
Undervoltage Correction |
2% output voltage regulation during undervoltages to 80 |
Severe Undervoltage Correction |
2% output voltage regulation during undervoltages to 65 (under 70% load only) |
User Interface, Alerts & Controls:
Switches |
2 switches control off/on power status and alarm-cancel/self-test operation |
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information - includes 4-LED meter display for load and battery charge level |
Surge / Noise Suppression:
UPS AC Suppression Joule Rating |
570 |
UPS AC Suppression Response Time |
Instantaneous |
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Cooling Method |
Fan
|
Primary Form Factor |
Tower |
Primary UPS Depth (mm) |
495 |
Primary UPS Height (mm) |
259 |
Primary UPS Width (mm) |
229 |
Shipping Dimensions (hwd / cm) |
37.59 x 58.67 x 31.50 |
Shipping Dimensions (hwd / in.) |
14.80 x 23.10 x 12.40 |
Shipping Weight (kg) |
26.76 |
Shipping Weight (lbs.) |
59.00 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
25.91 x 22.86 x 49.53 |
UPS Power Module Dimensions (hwd, in.) |
10.2 x 9 x 19.5 |
UPS Power Module Weight (kg) |
23.90 |
UPS Power Module Weight (lbs.) |
52.7 |
Environmental:
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
816 |
AC Economy Mode BTU / Hr. (Full |
169 |
Battery Mode BTU / Hr. (Full Load) |
889 |
AC Economy Mode Efficiency Rating (100% Load) |
87% |
AC Economy Mode Efficiency Rating (100% Load) |
97% |
Audible Noise |
< 45 dB at front side 1m |
Communications:
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Communications Interface |
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Tower |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 120V AC |
Output (VA) | 2200VA |
Output Voltage | 120V AC |
PDU Total Outlets | No |