Tripp Lite SmartOnline 3000VA 2400W RM 3U 120V SU3000RTXL3U - Refurbished

Tripp Lite SmartOnline 3000VA 2400W RM 3U
Model: SU3000RTXL3U
Input: NEMA L5-30P (120V - 30A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R, (1) NEMA L5-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Usually ships in 15-20 days

Usually ships in 15-20 days

Usually ships in 15-20 days

$599.99
Availability: On backorder

Usually ships in 15-20 days

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 3000VA 2400W, RM, 3U, 30A, 120V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU3000RTXL3U

Maximum output: 2400W / 3000VA
Typical backup time
at half load: 14 minutes (1200 Watts)
Typical backup time
at full load: 5 minutes (2400 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 3000VA 2400W RM 3U 120V SU3000RTXL3U User's Manual


SU3000RTXL3U - Tripp Lite SmartOnline 3000VA Specifications:

Input:

Rated input current (Maximum Load)

24A

Nominal Input Voltage(s) Supported

110V AC; 120V AC

UPS Input Connection Type

L5-30P

Input Circuit Breakers

40A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

30A 120V

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

3000

Output kVA Capacity (kVA)

3

Output Watt Capacity (Watts)

2400

Output kW Capacity (kW)

2.4

Power Factor

0.8

Crest Factor

3:1

Nominal Voltage Details

120V default

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets)

Output Circuit Breakers

15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)

Nominal Output Voltage(s) Supported

110V; 120V

Output Receptacles

(4) NEMA 5-15R

(4) NEMA 5-20R

(1) NEMA L5-30R

Individually Controllable Load Banks

Yes


Battery:

Full Load Runtime (min.)

5 min. (2400w)

Half Load Runtime (min.)

14 min. (1200w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

 BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 80% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

 RBC96-3U  (quantity 1)

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 80

Severe Undervoltage Correction

2% output voltage regulation during undervoltages to 65 (under 70% load only)


User Interface, Alerts & Controls:

Switches

2 switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions

LED Indicators

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery
and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

510

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description

Includes 4 post rackmount installation accessories

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Minimum Required Rack Depth with
External Battery Pack (cm)

81 

Minimum Required Rack Depth with
External Battery Pack (in.)

32

Minimum Required Rack Depth without External Battery Pack (cm)

79

Minimum Required Rack Depth
without External Battery Pack (in.)

31

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

660

Primary UPS Height (mm)

132

Primary UPS Width (mm)

452

Rack Height

3U

Shipping Dimensions (hwd / cm)

25.40 x 58.42 x 83.82

Shipping Dimensions (hwd / in.)

10.00 x 23.00 x 33.00 

Shipping Weight (kg)

50.80

Shipping Weight (lbs.)

112.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

13.21 x 45.21 x 66.04

UPS Power Module Dimensions (hwd, in.)

5.2 x 17.8 x 26

UPS Power Module Weight (kg)

33.48

UPS Power Module Weight (lbs.)

73.8 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1117

AC Economy Mode BTU / Hr. (Full Load)

523

Battery Mode BTU / Hr. (Full Load)

1224

AC Mode Efficiency Rating (100% Load)

91%

AC Economy Mode Efficiency Rating (100% Load)

94%


Communications:

Network Management Cards

 SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable
connection OR via select Network Management Card options

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralertt

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 3000VA
Output Voltage 120V AC
PDU Total Outlets No

You may also be interested in

Related Products