Description
Details
Love Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 5000VA 3500W, RM, 5U, 30A, 208/240V, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU5000RT3UHV
Maximum output: 3500W / 5000VA
Typical backup time at half load: 20 minutes (1750 Watts)
Typical backup time at full load: 8 minutes (3500 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 5000VA 3500W RM 5U 208/240V SU5000RT3UHV User's Manual
SU5000RT3UHV - Tripp Lite SmartOnline 5000VA Specifications:
Input:
Rated input current (Maximum Load) |
24A (208V), 21A (240V) |
||
Nominal Input Voltage(s) Supported |
200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
||
UPS Input Connection Type |
|
||
UPS Input Cord Length (ft.) |
10 |
||
UPS Input Cord Length (m) |
3.1 |
||
Recommended Electrical Service |
30A 208/240V |
||
Input Phase |
Single-Phase |
Output:
Output Volt Amp Capacity (VA) |
5000 |
||||
Output kVA Capacity (kVA) |
5 |
||||
Output Watt Capacity (Watts) |
3500 |
||||
Output kW Capacity (kW) |
3.5 |
||||
Power Factor |
0.7 |
||||
Crest Factor |
3:1 |
||||
Nominal Voltage Details |
Voltage selection via front panel LCD interface |
||||
Frequency Compatibility |
50 / 60 Hz |
||||
Frequency Compatibility Details |
Output frequency matches input nominal on startup |
||||
Output Voltage Regulation (Line Mode) |
+/- 2% |
||||
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||||
Output Circuit Breakers |
20A double-pole breaker protects L6-20R outlets, L6-30R outlets are unbreakered |
||||
Output AC Waveform (AC Mode) |
Pure Sine wave |
||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
Output Capacity Details |
Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 |
||||
Nominal Output Voltage(s) Supported |
200V; 208V; 220V; 240V |
||||
Output Receptacles |
|
||||
Individually Controllable Load Banks |
No |
Battery:
Full Load Runtime (min.) |
8 min. (3500w) |
Half Load Runtime (min.) |
20 min. (1750w) |
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
External Battery Pack Compatibility |
BP240V10RT3U ; BP240V557C-1PH; BP240V787C-1PH ; BP240V1037C1PH; BP240V1407C-1PH |
DC System Voltage (VDC) |
240 |
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
Yes |
Voltage Regulation:
Voltage Regulation Description |
Online, double-conversion power conditioning |
Overvoltage Correction |
2% output voltage regulation during overvoltages to 276 |
Undervoltage Correction |
2% output voltage regulation during undervoltages to 156 |
User Interface, Alerts & Controls:
Front Panel LCD Display |
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; |
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions |
Alarm Cancel Operation |
Alarm cancel switch |
Audible Alarm |
Unique audible alarms for all major UPS, environmental and power conditions (see manual) |
LED Indicators |
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD |
Surge / Noise Suppression:
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Cooling Method |
Fan
|
Included Battery Pack Dimensions |
3.5 x 17.5 x 22.5
|
Included Battery Pack Weight (kg) |
41.73
|
Included Battery Pack Weight (lbs.) |
92
|
Included Mounting Accessory Description |
2 sets of adjustable 4 post rack rails included |
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
Maximum Device Depth (cm) |
66.04 |
Maximum Device Depth (in.) |
26 |
Maximum Device Depth (mm) |
660 |
Minimum Required Rack Depth (cm) |
83.82 |
Minimum Required Rack Depth |
33 |
Optional Mounting Accessory Notes |
2 sets of 2POSTRMKITWM required for 2 post rackmount installation of separate power module and battery pack |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
660 |
Primary UPS Height (mm) |
132 |
Primary UPS Width (mm) |
445 |
Rack Height |
5U |
Shipping Dimensions (hwd / cm) |
55.88 x 68.58 x 85.09 |
Shipping Dimensions (hwd / in.) |
22.00 x 27.00 x 33.50 |
Shipping Weight (kg) |
110.22 |
Shipping Weight (lbs.) |
243.00 |
Unit Dimension Details |
Includes 3U UPS/power module and 2U battery pack |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
13.21 x 44.45 x 66.04 |
UPS Power Module Dimensions (hwd, in.) |
5.2 x 17.5 x 26 |
UPS Power Module Weight (kg) |
19.05 |
UPS Power Module Weight (lbs.) |
42 |
Environmental:
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
1327 |
Battery Mode BTU / Hr. (Full Load) |
1327 |
AC Mode Efficiency Rating (100% Load) |
90% |
AC Economy Mode Efficiency Rating (100% Load) |
94% |
Communications:
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
Network Monitoring Port Description |
RS232 and contact closure communications are located on two separate DB9 ports |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at |
Communications Cable |
DB9 cable included |
Communications Interface |
DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | No |
Output (VA) | 5000VA |
Output Voltage | No |
PDU Total Outlets | No |