1-866-311-1945 sales@excessups.com

United States United States [change]
25% OffFree Shipping

Tripp Lite OmniVS 1500VA 940W OMNIVS1500XL Line-Interactive UPS, Extended Run, Tower, USB - Refurbished

Tripp Lite OmniVS 1500VA 940W Tower UPS - Extended run capable
New batteries, Refurbished UPS
Model: OMNIVS1500XL
Input: NEMA 5-15P (120V 15A)
Output: (8) NEMA 5-15R
- 120V 15A
Line-Interactive UPS - Sinewave Output
1 Year Warranty Included

Availability: In stock

Regular Price: $199.99

Now only: $149.99

Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Tripp Lite OmniVS 120V 1500VA 940W Tower UPS - Line interactive, UPS, Extended Run, Tower, USB

Condition: New batteries, refurbished UPS
Part Number: OMNIVS1500XL
Maximum output: 940W / 1500VA
Typical backup time
at half load: 11.4 minutes (470W)
Typical backup time
at full load: 4 minutes (940W)
Warranty:
1 year full replacement warranty


Tripp Lite OmniVS 1500VA OMNIVS1500XL Owner's Manual

OMNIVS1500XL - Tripp Lite OmniVS 1500VA 940W Line Interactive UPS Specifications:

OUTPUT

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

940W

Nominal Output Voltage(s) Supported

120V

Nominal Voltage Details

120V default

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Automatic Frequency Selection

Output Voltage Regulation (Line Mode)

-18%, +8%

Output Voltage Regulation (Economy Line Mode)

+/- 5%

Output Receptacles

(8) 5-15R - 6x UPS Outlets, 2x Surge Only

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

INPUT

Rated input current (Maximum Load)

12A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

5-15P

Input Circuit Breakers

15A

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

BATTERY

Full Load Runtime (min.)

4 min. (940W)

Half Load Runtime (min.)

11.4 min. (470W)

Internal UPS Replacement Battery Cartridge

(1) RBC24-SLT

VOLTAGE REGULATION

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation an input voltage range of 75 to 147

Overvoltage Correction

Input voltages between 128V and 147V are reduced by 12%

Undervoltage Correction

Input voltages between 75V and 92V are boosted by 30%

USER INTERFACE, ALERTS & CONTROLS

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch. Once silenced, alarm will resound to indicate a low-battery status.

Audible Alarm

Audible alarm indicates power failure and overload conditions

LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status.

   

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

690

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes

PHYSICAL

Primary Form Factor

Tower

Shipping Weight (lbs)

28lbs

Cooling Method

Fan

UPS Housing Material

Polycarbonate

Primary UPS Height (mm)

300mm

Primary UPS Width (mm)

183mm

Primary UPS Depth (mm)

191mm

ENVIRONMENTAL

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

356

Battery Mode BTU / Hr. (Full Load)

480

AC Economy Mode Efficiency Rating (100% Load)

90%

COMMUNICATIONS

Communications Interface

USB

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 Supported, cabling NOT INCLUDED

LINE / BATTERY TRANSFER

Transfer Time

4ms (AC to Battery), 6ms (Battery to AC mode)

Low Voltage Transfer to Battery Power (Setpoint)

75V

High Voltage Transfer to Battery Power (Setpoint)

147V

SPECIAL FEATURES

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Hot swappable batteries

   

CERTIFICATIONS

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 1500VA