Call toll free: 1-866-311-1945 | sales@excessups.com
Your Region:

Tripp Lite SmartPro 2200VA 1920W RM 2U 120V SMART2600RM2U - Refurbished

Tripp Lite SmartPro 2200VA 1920W RM 2U
Model: SMART2600RM2U
Input: NEMA 5-20P (120V - 20A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R, (1) NEMA L5-20R
Line Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Usually ships in 15-20 days

Usually ships in 15-20 days

Usually ships in 15-20 days

$529.99
Availability: On backorder

Usually ships in 15-20 days

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 2200VA 1920W, RM, 20A, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART2600RM2U

Maximum output: 1920W / 2200VA
Typical backup time
at half load: 12.9 minutes (960 Watts)
Typical backup time
at full load: 4.6 minutes (1920 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 2200VA 1920W RM 2U 120V SMART2600RM2U Manual


SMART2600RM2U - Tripp Lite SmartPro 2200VA Specifications:

Input:

Rated input current (Maximum Load)

16A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-20P

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

20A 120V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

2200

Output kVA Capacity (kVA)

2.2

Output Watt Capacity (Watts)

1920

Output kW Capacity (kW)

1.92

Power Factor

0.87

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

14%, +6%

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Two switchable single-outlet 5-15R load banks

Output Circuit Breakers

15A breaker protects 5-15R, 20A breaker protects 5-15/20R, L5-20R is unbreakered

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(4) NEMA 5-15R

(4) NEMA 5-15/20R

(1) NEMA L5-20R


Individually Controllable Load Banks

Yes


Battery:

Full Load Runtime (min.)

4.6 min. (1920w)

Half Load Runtime (min.)

12.9 min. (960w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

External Battery Pack Compatibility

BP48V24-2U  (limit 1);  BP48V60RT-3U  (multi-pack compatible);  BP48V27-2US  (multi-pack compatible)

DC System Voltage (VDC)

48

Battery Recharge Rate (Included Batteries) 

Less than 4.5 hours from 10% to 90% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

RBC94-2U

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145

Overvoltage Correction

Input voltages between 127 and 147 are reduced by 12%

Undervoltage Correction

Input voltages between 95 and 104 are boosted by 12%

Severe Undervoltage Correction 

Input voltages between 83 and 94 are boosted by 24%


User Interface, Alerts & Controls:

Front Panel LCD Display

Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)

Switches

3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions

Alarm Cancel Operation

Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description 

Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported
with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); 4 post rackmount shortdepth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )

Minimum Required Rack Depth with
External Battery Pack (cm)

67

Minimum Required Rack Depth with
External Battery Pack (in.)

26.46

Minimum Required Rack Depth
without External Battery Pack (cm)

62

Minimum Required Rack Depth
without External Battery Pack (in.)

24.46

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

494

Primary UPS Height (mm)

88

Primary UPS Width (mm)

440

Rack Height

2U

Shipping Dimensions (hwd / cm)

22.86 x 61.21 x 55.88

Shipping Dimensions (hwd / in.)

9.00 x 24.10 x 22.00 

Shipping Weight (kg)

36.79

Shipping Weight (lbs.)

81.10

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

8.79 x 43.99 x 49.43

UPS Power Module Dimensions (hwd, in.)

3.46 x 17.32 x 19.46

UPS Power Module Weight (kg)

29.03

UPS Power Module Weight (lbs.)

64 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

250

Battery Mode BTU / Hr. (Full Load)

980

AC Mode Efficiency Rating (100% Load)

96%

Audible Noise

45 dBA maximum, front side 1m


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 2200VA
Output Voltage 120V AC
PDU Total Outlets No

You may also be interested in