1-866-311-1945 sales@excessups.com

United States United States [change]
17% Off

Tripp Lite SmartPro LCD 1500VA 900W 120V LCD SMART1500LCDT - Refurbished

Refurbished Tripp Lite SmartPro UPS 1500VA 900W Tower
Model: SMART1500LCDT

Input: NEMA 5-15P (120V 15A)
Output: (10) NEMA 5-15R
- (5) Surge, (5) Battery + Surge
Line-Interactive UPS - PWM sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included

Availability: Out of stock

Regular Price: $119.99

Now only: $99.99

Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Refurbished Tripp Lite SmartPro LCD 1
500VA 900W 120V Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets
Condition: New batteries, refurbished UPS
Part Number: SMART1500LCDT
Maximum output: 900W / 1500VA
Typical backup time
at half load: 10.0 minutes (450W)
Typical backup time
at full load: 4 minutes (900Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SMART1500LCDT Owner's Manual

SMART1500LCDT - Tripp Lite SmartPro 1500VA Specifications:

OUTPUT

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

900W

Nominal Output Voltage(s) Supported

120V

Nominal Voltage Details

120V default

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Automatic Frequency Selection

Output Voltage Regulation (Line Mode)

-10%, +6%

Output Voltage Regulation (Economy Line Mode)

+/- 5%

Output Receptacles

(10) 5-15R

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

PWM Sine wave

INPUT

Rated input current (Maximum Load)

12A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

5-15P

Input Circuit Breakers

20A

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

BATTERY

Full Load Runtime (min.)

4 min. (900W)

Half Load Runtime (min.)

10 min. (450W)

Internal UPS Replacement Battery Cartridge

(2) RBC51

VOLTAGE REGULATION

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation an input voltage range of 92 to 150

Overvoltage Correction

Input voltages between 129V and 147V are reduced by 15%

Undervoltage Correction

Input voltages between 92V and 108V are boosted by 18%

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display

LCD screen with scroll buttons indicates Input voltage, Output voltage, Frequency (Hz), AVR boost / cut status, Output load in watts, Output load percentage, Battery voltage and Estimated runtime in minutes

Switches

Power switch offers whole UPS power control; Scroll/mute button enables LCD selection options and silences audible alarm; Test button initiates self test

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm cancel switch

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

650

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes

PHYSICAL

Primary Form Factor

Tower

Shipping Weight (kg)

13.3kg

Cooling Method

Fan

UPS Housing Material

Steel

Primary UPS Height (mm)

203mm

Primary UPS Width (mm)

146mm

Primary UPS Depth (mm)

391

ENVIRONMENTAL

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

119

Battery Mode BTU / Hr. (Full Load)

867

AC Economy Mode Efficiency Rating (100% Load)

95%

COMMUNICATIONS

Communications Interface

USB (HID enabled)

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

Communications Cable

USB (NOT INCLUDED)

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer Time

2ms (AC to Battery), 6ms (Battery to AC mode)

Low Voltage Transfer to Battery Power (Setpoint)

92V

High Voltage Transfer to Battery Power (Setpoint)

150V

SPECIAL FEATURES

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Hot swappable batteries

Green Energy-Saving Features

95% Efficiency

CERTIFICATIONS

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Stepped Sinewave
Input Voltage 120V AC
Output (VA) 1500VA
Output Voltage 120V AC