Tripp Lite SmartOnline 16000VA 11200W RM 8U 208V/240V SU16000RT4U - Refurbished

Tripp Lite SmartOnline UPS 16kVA 11.2kW RM 8U 208-240V
Model: SU16000RT4U
Input: Hardwire (208V/240V - 70A)
Output: (5) NEMA 5-15/20R, (2) NEMA L6-30R, (6) C19, Hardwire
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
$4,999.99
Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 16000VA 11200W, RM, 8U, 70A, 208V-240V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU16000RT4U

Maximum output: 11200W / 16000VA
Typical backup time
at half load: 12 minutes (5600 Watts)
Typical backup time
at full load: 5 minutes (11200 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 16000VA 11200W RM 8U 208V-240V SU16000RT4U User's Manual


SU16000RT4U - Tripp Lite SmartPro 16000VA Specifications:

Output:

Output Volt Amp Capacity (VA)

16000

Output kVA Capacity (kVA)

16

Output Watt Capacity (Watts)

11200

Output kW Capacity (kW)

11.2

Power Factor

0.7

Crest Factor

3:1

Nominal Voltage Details

240/120V or 208/120V split phase output

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

+/- 3%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 3%

Output Receptacle Details

Supports North American 208/120V or 240/120V split-phase hardwire output (L1, L2, N, G)

Output Circuit Breakers

20A branch rated double pole breakers (x3) protect 2 C19 and 1 5-15/20R outlets each, 30A branch rated double pole breakers (x2) protect 1 L6-30R outlet each, 20A single pole breakers (x2) protect one 5-15/20R outlet each

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

16,000VA, 11,200W (240V) / 13,860VA, 11,200W (208V); Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared

Nominal Output Voltage(

120V; 208V; 240V

Output Receptacles

(5) NEMA 5-15/20R

(2) NEMA L6-30R

(6) C19

 

Hardwire

 

Individually Controllable Load Banks

No


Input:

Rated input current (Maximum Load)

68A

Nominal Input Voltage(s) Supported

120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)

UPS Input Connection Type

Hardwire

 

UPS Input Connection Description

4 wire split-phase input (L1, L2, N, G)

Recommended Electrical Service

70A 208/240-120 Split Phase (L1, L2, N, G); 4 AWG wiring recommended

Input Phase

Single-Phase


Battery:

Full Load Runtime (min.)

5 min. (11200W)

Half Load Runtime (min.)

12 min. (5600W)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

BP192V18-4U

DC System Voltage (VDC)

192

Battery Recharge Rate (Included Batteries)

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Replacement Description

Hot-swappable, user replaceable external battery packs

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

+/-3% output voltage regulation in online, double-conversion mode

Overvoltage Correction

Corrects overvoltages to 140 (measured L1-N : L2-N)

Undervoltage Correction

Corrects undervoltages to 65V (measured L1-N : L2-N)


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

3620

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Battery Pack Dimensions (hwd / in.)

7 x 17.5 x 27.8

Included Battery Pack Weight (kg)

108.41

Included Battery Pack Weight (lbs.)

239

Included Mounting Accessory Description

2 sets of adjustable 4 post rack rails included

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Maximum Device Depth (cm)

86.36

Maximum Device Depth (in.)

34

Maximum Device Depth (mm)

864

Minimum Required Rack Depth (cm)

101.60

Minimum Required Rack Depth (inches)

40

Optional Mounting Accessory Notes

2 sets of  2POSTRMKITHD  required for 2 post rackmount installation of separate power module and battery pack

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

706

Primary UPS Height (mm)

178

Primary UPS Width (mm)

445

Rack Height

8U

Shipping Dimensions (hwd / cm)

91.44 x 60.96 x 86.36

Shipping Dimensions (hwd / in.)

36.00 x 24.00 x 34.00

Shipping Weight (kg)

203.57

Shipping Weight (kg)

448.80

UPS Dimensions Details

Includes 4U battery pack, 4U UPS/power module and detachable bypass PDU; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

17.78 x 44.45 x 70.61

UPS Power Module Dimensions (hwd, in.)

7 x 17.5 x 27.8

UPS Power Module Weight (kg)

39.01

UPS Power Module Weight (lbs.)

86


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

RS232 and contact closure communications are supported on one DB9 port

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

Communications Interface

USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC, 240V AC
Output (VA) 16000VA
Output Voltage 120V AC
PDU Total Outlets No