Description
Details
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 16000VA 11200W, RM, 8U, 70A, 208V-240V, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU16000RT4U
Maximum output: 11200W / 16000VA
Typical backup time at half load: 12 minutes (5600 Watts)
Typical backup time at full load: 5 minutes (11200 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 16000VA 11200W RM 8U 208V-240V SU16000RT4U User's Manual
SU16000RT4U - Tripp Lite SmartPro 16000VA Specifications:
Output:
Output Volt Amp Capacity (VA) |
16000 |
||||||||
Output kVA Capacity (kVA) |
16 |
||||||||
Output Watt Capacity (Watts) |
11200 |
||||||||
Output kW Capacity (kW) |
11.2 |
||||||||
Power Factor |
0.7 |
||||||||
Crest Factor |
3:1 |
||||||||
Nominal Voltage Details |
240/120V or 208/120V split phase output |
||||||||
Frequency Compatibility |
60 Hz |
||||||||
Output Voltage Regulation (Line Mode) |
+/- 3% |
||||||||
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||||||
Output Voltage Regulation (Battery Mode) |
+/- 3% |
||||||||
Output Receptacle Details |
Supports North American 208/120V or 240/120V split-phase hardwire output (L1, L2, N, G) |
||||||||
Output Circuit Breakers |
20A branch rated double pole breakers (x3) protect 2 C19 and 1 5-15/20R outlets each, 30A branch rated double pole breakers (x2) protect 1 L6-30R outlet each, 20A single pole breakers (x2) protect one 5-15/20R outlet each |
||||||||
Output AC Waveform (AC Mode) |
Pure Sine wave |
||||||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||||||
Output Capacity Details |
16,000VA, 11,200W (240V) / 13,860VA, 11,200W (208V); Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared |
||||||||
Nominal Output Voltage( |
120V; 208V; 240V |
||||||||
Output Receptacles |
|
||||||||
Individually Controllable Load Banks |
No |
Input:
Rated input current (Maximum Load) |
68A |
||
Nominal Input Voltage(s) Supported |
120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G) |
||
UPS Input Connection Type |
|
||
UPS Input Connection Description |
4 wire split-phase input (L1, L2, N, G) |
||
Recommended Electrical Service |
70A 208/240-120 Split Phase (L1, L2, N, G); 4 AWG wiring recommended |
||
Input Phase |
Single-Phase |
Battery:
Full Load Runtime (min.) |
5 min. (11200W) |
Half Load Runtime (min.) |
12 min. (5600W) |
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
External Battery Pack Compatibility |
BP192V18-4U |
DC System Voltage (VDC) |
192 |
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
Battery Replacement Description |
Hot-swappable, user replaceable external battery packs |
Expandable Runtime |
Yes |
Voltage Regulation:
Voltage Regulation Description |
+/-3% output voltage regulation in online, double-conversion mode |
Overvoltage Correction |
Corrects overvoltages to 140 (measured L1-N : L2-N) |
Undervoltage Correction |
Corrects undervoltages to 65V (measured L1-N : L2-N) |
User Interface, Alerts & Controls:
Front Panel LCD Display |
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats |
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement |
Alarm Cancel Operation |
Alarm cancel switch |
Audible Alarm |
Unique audible alarms for all major UPS, environmental and power conditions (see manual) |
LED Indicators |
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options |
Surge / Noise Suppression:
UPS AC Suppression Joule Rating |
3620 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Cooling Method |
Fan |
Included Battery Pack Dimensions (hwd / in.) |
7 x 17.5 x 27.8 |
Included Battery Pack Weight (kg) |
108.41 |
Included Battery Pack Weight (lbs.) |
239 |
Included Mounting Accessory Description |
2 sets of adjustable 4 post rack rails included |
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount |
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
Maximum Device Depth (cm) |
86.36 |
Maximum Device Depth (in.) |
34 |
Maximum Device Depth (mm) |
864 |
Minimum Required Rack Depth (cm) |
101.60 |
Minimum Required Rack Depth (inches) |
40 |
Optional Mounting Accessory Notes |
2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
706 |
Primary UPS Height (mm) |
178 |
Primary UPS Width (mm) |
445 |
Rack Height |
8U |
Shipping Dimensions (hwd / cm) |
91.44 x 60.96 x 86.36 |
Shipping Dimensions (hwd / in.) |
36.00 x 24.00 x 34.00 |
Shipping Weight (kg) |
203.57 |
Shipping Weight (kg) |
448.80 |
UPS Dimensions Details |
Includes 4U battery pack, 4U UPS/power module and detachable bypass PDU; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
17.78 x 44.45 x 70.61 |
UPS Power Module Dimensions (hwd, in.) |
7 x 17.5 x 27.8 |
UPS Power Module Weight (kg) |
39.01 |
UPS Power Module Weight (lbs.) |
86 |
Communications:
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
Network Monitoring Port Description |
RS232 and contact closure communications are supported on one DB9 port |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
USB and DB9 cabling included |
Communications Interface |
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 208V AC, 240V AC |
Output (VA) | 16000VA |
Output Voltage | 120V AC |
PDU Total Outlets | No |