1-866-311-1945 sales@excessups.com

United States United States [change]

Tripp Lite SmartOnline UPS 5000VA 200-240V SU5000RT4UHV - Refurbished

Refurbished SmartOnline UPS 5000VA SU5000RT4UHV
Model: SU5000RT4UHV
Input: NEMA L6-30P (208V 30A)
Output: NEMA L6-30R, NEMA L6-20R
Double-Conversion UPS - Pure Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included

Availability: Out of stock

$1,599.99
Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Refurbished SmartOnline UPS 5000VA 200-240V with New Batteries
Condition: New batteries, refurbished UPS
Part Number: SU5000RT4UHV
Maximum output:
4500W / 5000VA
Typical backup time
at half load: 11.0 minutes (2250 Watts)
Typical backup time
at full load: 3.5 minutes (4500 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline UPS 5000VA SU5000RT4UHV Manual

 


SU5000RT4UHV - Tripp Lite SmartOnline UPS 5000VA Specifications:

Output:

OUTPUT
Output Volt Amp Capacity (VA) 5000
Output kVA capacity (kVA) 5.0
Output Watt Capacity (watts) 4500
Output kW capacity 4.5
Output power factor 0.9
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 240V
Frequency compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency compatibility details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 2%
Built-in UPS output receptacles 2 L6-20R outlet(s); 2 L6-30R outlet(s)
Output circuit breaker 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered
Output AC waveform (AC mode) Pure Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT
Rated input current (at maximum load) 24A (200V), 24A (208V), 23.6A (220V), 23A (230V), 21.7A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 240V AC
Nominal input voltage description Factory configured to 208V
UPS input connection type L6-30P
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 30A
Phase Single-Phase
BATTERY
Full load runtime (minutes) 3.5 minutes (4500 watts)
Half load runtime (minutes) 11 minutes (2250 watts)
Expandable battery runtime Supports extended runtime with optional external battery packs
External battery pack compatibility BP192V12-3U
DC system voltage (VDC) 192
Battery recharge rate (included batteries) 6 hours (from 10% to 90%)
Replacement battery cartridge (internal UPS battery replacement) RBC5-192 (qty 1)
Battery Access Front panel battery access
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description Online, double-conversion power conditioning
Overvoltage correction 2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less)
Undervoltage correction 2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less)
LEDS ALARMS & SWITCHES
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Front panel LCD display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation Alarm cancel switch
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions
SURGE / NOISE SUPPRESSION
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL
Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 6.85 x 17.5 x 20.7
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 17.4 x 44.5 x 52.6
Rack Height 4U
Secondary form factor Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) 113.6
UPS / Power Module weight (kg) 51.6
UPS Shipping dimensions (height x width x depth / inches) 12.7 x 23.6 x 29.1
UPS Shipping dimensions (height x width x depth / cm) 32.3 x 60 x 73.9
Shipping weight (lbs) 151.8
Shipping weight (kg) 68.9
Cooling method Fan
UPS housing material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 5% to 90% (non-condensing)
AC mode BTU / hr. (full load) 1767
AC economy mode BTU / hr. (full load) 638
Battery mode BTU / hr. (full load) 1767
AC economy mode efficiency rating (100% load) 96%
Operating Elevation (ft.) 0 to 6560 ft. / 0 to 2000 m
Audible Noise 65 dB at 1m front side
Operating Elevation (m) 0-2000 m
COMMUNICATIONS
Communications interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description Two contact closure monitoring options available - RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module)
PowerAlert software Included
Communications cable USB, DB9 serial and EPO cables included
WatchDog compatibility Yes
LINE / BATTERY TRANSFER
Transfer time No transfer time (0 ms.) in online, double-conversion mode
Transfer time (economy mode) 8 ms. typical power failure response in optional economy mode
Low voltage transfer to battery power (setpoint) 156V (full load) / 100V (50% load or less, derates linearly)
High voltage transfer to battery power (setpoint) 280V (full load) / 300V (90% load or less)
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) Cold-start operation supported
High availability UPS features Automatic inverter bypass; Hot swappable batteries
Green & high efficiency features High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
UPS Certification details IEC 61000-4-5 1995 B Surge Immunity

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage No
Output (VA) 5000VA
Output Voltage No