APC Back-UPS 750VA 450W 120V
Model: BE750G
Input: NEMA 5-15P
Output: (5) NEMA 5-15R (Battery Backup) , (5) NEMA 5-15R (Battery Backup)
Line Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: APC
Model: APC Back-UPS 750VA 450W 120V
Condition: New batteries, refurbished UPS
Part Number: BE750G
Maximum output: 450W / 750VA
Typical backup time at half load: 11.4 minutes (225 Watts)
Typical backup time at full load: 2.2 minutes (450 Watts)
Warranty: 1 year full replacement warranty
APC Back-UPS 750VA 450W 120V BE750G - User Manual
BE750G - APC Back-UPS Specifications:
Main:
|
Main Input Voltage |
120V |
||||
|
Main Output Voltage |
120V |
||||
|
Rated Power in W |
450W |
||||
|
Rated Power in VA |
750VA |
||||
|
Input Connection Type |
|
||||
|
Output Connection Type |
|
||||
|
Cable Length |
5 ft (1.52 m) |
||||
|
Number of Cables |
1 |
||||
|
Battery Type |
Lead-Acid Battery |
Â
General:
|
Number of Power Module Filled Slots |
0 |
|
Number of Power Module Free Slots |
0 |
|
Redundant |
No |
Physical:
|
Color |
Black |
|
Height |
3.54 in (9 cm) |
|
Width |
7.09 in (18 cm) |
|
Depth |
14.29 in (36.3 cm) |
|
Net Weight |
10.58 lb(US) (4.8 kg) |
|
Mounting Preference |
No Preference |
|
Mounting Mode |
Not Rack-Mountable |
|
Two Post Mountable |
0 |
|
USB Compatible |
No |
Input:
|
Efficiency at Full Load |
88 - 139 V |
|
Input Frequency |
50/60 Hz +/- 3 Hz auto-sensing |
Output:
|
Max Configurable Power (Watts) |
450W |
|
Output Frequency (sync to mains) |
50/60 Hz +/- 3 Hz sync to mains |
|
Topology |
Standby |
|
Waveform Type |
Stepped Approximation to a Sinewave |
|
Maximum Output Current |
10 A |
|
Maximum Configurable Power in VA |
750VA |
|
Transfer Time |
8ms typical : 12ms maximum |
|
Output Frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 sync to mains |
Conformance:
|
Product Certifications |
California (CEC) Battery Charger |
Environmental:
|
Acoustic Level |
45 dBA
|
|
Heat Dissipation |
47 Btu/h |
|
Operating Altitude |
0Â - 10000 ft |
|
Ambient Air Temperature for Operation |
32 - 104 °F (0 - 40 °C) |
|
Ambient Air Temperature for Storage |
5 - 113°F (-15 - 45°C) |
|
Relative Humidity |
5 - 95 % |
Batteries & Runtime:
|
Extendable Run Time |
0 |
|
Battery Slots Empty |
0 |
|
Typical Recharge Time |
16 h |
|
RBC Quantity |
1 |
|
Battery Life |
3-5 years |
|
Replacement Battery |
RBC17 |
|
Battery Power in VAH |
104 VAh runtime |
|
Battery Charge Power (Watts) |
6 W rated |
Communications & Management:
|
Control Panel |
LED status display with On Line : On Battery : Replace Battery and Building Wiring Fault |
|
Emergency Power Off (EPO) |
Optional |
|
Free Slots |
1 |
|
Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays |
Surge Protection and Filtering:
|
Surge Energy Rating |
354 J
|
|
Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : mee |
|
Data Line Protection |
Coaxial cable for CATV/SATV/modem/audio-video |