Call toll free: 1-866-311-1945 | sales@excessups.com
Your Region:

Tripp Lite Smart-Online UPS 3000VA 2700W LCD RM 2U 120V SU3000LCD2UHV - Refurbished

Tripp Lite Smart-Online 3000VA 2700W RM 2U LCD
Model: SU3000LCD2UHV
Input: NEMA L6-20P (200/208/220/230/240V)
Output: (6) NEMA 6-15/20R, (2) NEMA L6-20R
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Regular Price: $2,199.99

$1,299.99

Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 3000VA 2700W, LCD, Tower, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SU3000LCD2UHV 

Maximum output: 2700W / 3000VA
Typical backup time
at half load:13.5 minutes (1350 Watts)
Typical backup time
at full load: 5 minutes (2700 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 3000VA 2700W Tower 120V SU3000LCD2UHV  Manual


SU3000LCD2UHV  - Tripp Lite SmartOnline 3000VA Specifications:

Input:

Rated input current (Maximum Load)

14.97A

Nominal Input Voltage(s) Supported

200V AC; 208V AC; 220V AC; 230V AC; 240V AC

UPS Input Connection Type

NEMA L6-20P

Input Circuit Breakers

40A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

20A 208V/240V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

3000

Output Capacity (kVA)

3.0

Output Watt Capacity (Watts)

2700

Output kW Capacity (kW)

2.7

Output Capacity Details

ODE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 1890 watts for 208/220/230/240V output voltages; Max output is reduced to 2160W at 200V output voltage in all operating modes OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

Nominal output voltage is user configured on first power-on

Frequency Compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

Frequency Compatibility Details

Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank)

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

200V; 208V; 220V; 230V; 240V

Output Receptacles

(6) NEMA 6-15/20R

(2) NEMA L6-20R

Individually Controllable Load Banks

Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

5 min. (2700w)

Half Load Runtime (min.)

13.5 min. (1350w)

Expandable Battery Runtime

BP72V18-2US  (multi-pack compatible)

Expandable Runtime

Yes

Expandable Runtime Description

External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries)

Less than 3 hours from 10% to 90% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC72S

Battery Replacement Description

Hot-swappable, user replaceable batteries


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)


User Interface, Alerts & Controls:

Front Panel LCD Display

Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options

Switches

5 front panel switches: On/Off, Up, Down and Escape

Alarm Cancel Operation

Power-fail alarm can be silenced by following on-screen prompts

Audible Alarm

Audible alarm indicates power failure, low battery, overload and fault

LED Indicators                                        

S4 front panel LEDs: AC input (green),

AC output (green), Battery (yellow),

Fault (red)

Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

Single line dialup / network dataline protection included

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Primary UPS Depth (mm)


616

Primary UPS Height (mm)

88

Primary UPS Width (mm)

438

Shipping Dimensions (hwd / cm)

24.00 x 59.99 x 76.00

Shipping Weight (kg)

39.01

Shipping Weight (lbs.)

76.00

UPS Housing Material

Metal

UPS Power Module Dimensions (hwd, cm)

8.79 x 43.79 x 61.60

UPS Power Module Weight (kg)


32.12

 
Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

5 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)


933

Battery Mode BTU / Hr. (Full Load)

1399

AC Mode Efficiency Rating (100% Load)

>90%

Audible Noise

<50dB at front side 1M

Operating Elevation (m)

0-10000 ft. (0-3000 m)


Communications:

Network Management Cards

WEBCARDLX 

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 plus assignable contact closure pin functions for On-battery, On bypass, Output-on and Low-battery conditions and remote Shutdown, Output-off, Reboot and Power-toggle operations

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert

Communications Cable

USB and DB9 cabling included

 

 

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

 

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Pure Sinewave
Input Voltage 240V AC
Output (VA) 3000VA
Output Voltage 208V AC, 230V AC (EU), 240V AC
PDU Total Outlets No