APC AP8641 Rack PDU 2G, Metered by Outlet with Switching, 0U, 30A, 208V
Model: AP8641
Input: NEMA L6-30P (208V - 30A)
Output: (21) IEC C13, (3) IEC C19
4992VA Load Capacity
Switched PDU with Individual Outlet Power Metering & Remote Outlet Control
Built-In Network Management for Remote Monitoring & Control
Refurbished PDU
1 Year Full Replacement Warranty Included
In stock
Manufacturer: APC
Model: APC Rack PDU 2G, Metered by Outlet with Switching, Zero U, 30A, 200/208V
Condition: Refurbished PDU
Part Number: AP8641
Input: NEMA L6-30P, 200/208/230V, 30A Maximum
Output: 200/208V, (21) IEC C13 + (3) IEC C19
Load Capacity: 4992VA
PDU Type: Switched, Metered by Outlet
Form Factor: Zero U (0U), Vertical Rackmount
Warranty: 1 Year Full Replacement Warranty, Additional Warranty Available
Description: The APC AP8641 is a 0U, 30A switched rack PDU with individual outlet-level power metering and remote outlet control. It provides (21) IEC C13 and (3) IEC C19 outlets, real-time load monitoring, configurable alarms, power sequencing, and remote power cycling for connected equipment.
Â
Â
Â
APC Rack PDU 2G, Metered by Outlet with Switching - User Manual
Â
Â
APC AP8641 PDU Specifications:
| Main | Â |
| Manufacturer | APC |
| Model | AP8641 |
| Product or Component Type | PDU |
| PDU Type | Switched Metered Outlet |
| Metering | Individual Outlet Power Metering |
| Switching | Individual Outlet Switching |
| Form Factor | Zero U (0U) |
| Mounting Mode | Rack-Mounted |
| Mounting Position | Vertical |
| Main Input Voltage | 200V / 208V / 230V |
| Main Output Voltage | 200V / 208V |
| Input Connection Type | NEMA L6-30P |
| Input Current Limit | 30A |
| Rated Current | 24A |
| Maximum Current Draw | 30A |
| Load Capacity | 4992VA |
| Number of Power Socket Outlets | 24 Total |
| Output Connections | (21) IEC 60320 C13, (3) IEC 60320 C19 |
| Protection Type | Circuit Breaker |
| Number of Rack Units | 0U |
| Number of Cables | 1 |
| Cable Length | 9.5 ft (2.9 m) |
| Â | Â |
| Input | Â |
| Nominal Input Voltage | 200V / 208V / 230V |
| Permissible Input Voltage | 200–240V |
| Network Frequency | 50/60 Hz |
| Input Connection | NEMA L6-30P |
| Maximum Input Current | 30A |
| Maximum Line Current | 30A |
| Regulatory / Rated Current | 24A |
| Load Capacity | 4992VA |
| Number of Power Cords | 1 |
| Power Cord Length | 9.5 ft (2.9 m) |
| Â | Â |
| Output | Â |
| Nominal Output Voltage | 200V / 208V |
| Total Outlets | 24 |
| IEC 60320 C13 Outlets | (21) |
| IEC 60320 C19 Outlets | (3) |
| Maximum Current Draw | 30A |
| Overload Protection | Yes |
| Protection Type | Circuit Breaker |
| Individual Outlet Switching | Yes |
| Remote Outlet On / Off | Yes |
| Remote Outlet Power Cycling | Yes |
| Individual Outlet Metering | Yes |
| Power Sequencing | Supported |
| Configurable Power-On / Power-Off Delays | Supported |
| Load Shedding | Supported |
| Â | Â |
| Metering & Monitoring | Â |
| Metering Type | Metered by Outlet |
| Individual Outlet Power Metering | Yes |
| Current Metering | Yes |
| Real-Time Load Monitoring | Yes |
| Remote Load Monitoring | Yes |
| User-Defined Alarms | Supported |
| Circuit Overload Warning | Supported |
| Load Threshold Monitoring | Supported |
| Individual Outlet Control | Supported |
| Power Control | User Configurable |
| Â | Â |
| Communications & Management | Â |
| Network Management | Built-In |
| Remote PDU Management | Supported |
| Secure Web Management | Supported |
| SNMP Management | Supported |
| Telnet Management | Supported |
| Remote Outlet Control | Supported |
| Remote Outlet On / Off | Supported |
| Remote Outlet Reboot / Power Cycling | Supported |
| Power Sequencing | Supported |
| User-Defined Power Sequencing Delays | Supported |
| Load Shedding Configuration | Supported |
| Real-Time Current Monitoring | Supported |
| User-Defined Load Alarms | Supported |
| Temperature / Humidity Sensor Port | Yes |
| Environmental Monitoring | Supported with Compatible Sensor |
| Centralized APC Management | Supported |
| APC InfraStruxure Central | Supported |
| APC Capacity Manager | Supported |
| APC Change Manager | Supported |
| Serial Configuration | Supported |
| Serial Configuration Cable | Included |
| Â | Â |
| Physical | Â |
| Color | Black |
| Rack Height | 0U |
| Mounting Location | Side |
| Mounting Mode | Rack-Mounted |
| Mounting Position | Vertical |
| Height | 72.008 in (1829 mm) |
| Width | 2.20 in (56 mm) |
| Depth | 2.008 in (51 mm) |
| Net Weight | 18.14 lb (8.23 kg) |
| Â | Â |
| Environmental | Â |
| Operating Temperature | 23–140°F (-5–60°C) |
| Relative Humidity | 5–95% |
| Operating Altitude | 0–10,000 ft (0–3,048 m) |
| Storage Temperature | -13–149°F (-25–65°C) |
| Storage Relative Humidity | 5–95% |
| Storage Altitude | 0–50,000 ft (0–15,240 m) |
| Â | Â |
| Conformance | Â |
| cUL Listed | Yes |
| UL Listed | Yes |
| PSE | Yes |
| VCCI | Class A |
| FCC | Part 15 Class A |
| ICES | ICES-003 |