APC AP8659NA3 Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 208V, 20A
Model: AP8659NA3
Input: NEMA L6-20P (208V - 20A)
Output: (21) IEC C13, (3) IEC C19
Load Capacity: 3300VA
Metered by Outlet - Individual Outlet-Level Power Monitoring
Switched Outlets - Individual Remote ON/OFF Control
Remote Power Cycling, Reboot & Power Sequencing
Real-Time Load Monitoring & User-Defined Overload Alarms
Built-In Network Management - Web, SNMP & Telnet
Refurbished PDU with Verified Functionality
1-Year Full Replacement Warranty Included
In stock
Manufacturer: APC
Model: AP8659NA3
Description: Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 208V, (21) C13 & (3) C19
Condition: Refurbished PDU
Part Number: AP8659NA3
Input: NEMA L6-20P, 208V, 20A
Output: (21) IEC C13, (3) IEC C19
Load Capacity: 3300VA
PDU Type: Metered by Outlet with Switching
Remote Outlet Switching: Yes – Individual Outlet Control
Outlet-Level Metering: Yes
Network Management: Built-In – Web, SNMP & Telnet
Form Factor: Vertical ZeroU Rackmount
Warranty: 1 Year Full Replacement Warranty
APC AP8659NA3 Rack PDUMetered by Outlet with Switching - User Manual
AP8659NA3 - APC Metered by Outlet with Switching Specifications:
| Main | ||
| Manufacturer | APC by Schneider Electric | |
| Model / Part Number | AP8659NA3 | |
| Product Type | Rack Power Distribution Unit (PDU) | |
| PDU Type | Metered by Outlet with Switching | |
| PDU Generation | Rack PDU 2G | |
| Form Factor | Vertical ZeroU | |
| Nominal Input Voltage | 208V | |
| Supported Main Input Voltages | 200V / 208V / 230V | |
| Nominal Output Voltage | 208V | |
| Load Capacity | 3300VA | |
| Input Connection | NEMA L6-20P | |
| Output Connections | (21) IEC C13, (3) IEC C19 | |
| Total Outlets | 24 | |
| Remote Outlet Switching | Yes | |
| Individual Outlet Metering | Yes | |
| Input | ||
| Nominal Input Voltage | 208V AC | |
| Supported Main Input Voltages | 200V / 208V / 230V | |
| Input Connection | NEMA L6-20P | |
| Input Current Limit | 20A | |
| Rated Current | 16A | |
| Maximum Current Draw | 16A | |
| Network Frequency | 50/60Hz | |
| Permissible Voltage | 100–240V | |
| Input Phase | Single-Phase | |
| Input Cord Length | 9.5 ft (2.9 m) | |
| Number of Input Power Cords | 1 | |
| Output | ||
| Nominal Output Voltage | 208V AC | |
| Load Capacity | 3300VA | |
| Total Output Receptacles | 24 | |
| IEC C13 Outlets | (21) IEC 60320 C13 | |
| IEC C19 Outlets | (3) IEC 60320 C19 | |
| Outlet Type | Locking IEC Receptacles | |
| PDU Output Management | Metered by Outlet with Switching | |
| Individual Outlet Metering | Yes | |
| Individual Outlet Switching | Yes | |
| Remote Individual Outlet Control | Yes | |
| Remote Outlet ON/OFF | Yes | |
| Remote Power Cycling | Yes – Allows Rebooting of Locked-Up Equipment | |
| Controllable Receptacles | Yes | |
| Power Sequencing | Yes | |
| User-Configurable Power Sequencing | Yes | |
| Power-Up Sequencing | Yes | |
| Power-Down Sequencing | Yes | |
| Sequencing Delays | User Configurable | |
| Load Shedding | Yes | |
| Load Prioritization | Yes | |
| Unauthorized Outlet Use Prevention | Yes – Individual Outlets Can Be Remotely Disabled | |
| Real-Time Outlet Monitoring | Yes | |
| Outlet-Level Power Metering | Yes | |
| Current Monitoring | Real-Time Remote Monitoring of Connected Loads | |
| Real Power Monitoring | Yes | |
| User-Defined Load Alarms | Yes | |
| Overload Warning | Yes – User-Defined Alarms Can Warn Before Critical Overload Conditions | |
| Remote Management Interface | Web, SNMP & Telnet | |
| Circuit Breaker | No – Without Circuit Breaker | |
| Metering & Power Monitoring | ||
| Outlet-Level Power Metering | Yes | |
| Real-Time Load Monitoring | Yes | |
| Current Metering | Yes | |
| Real Power Monitoring | Yes | |
| Remote Power Monitoring | Yes | |
| User-Defined Load Alarms | Yes | |
| Circuit Overload Warning | Yes | |
| Individual Outlet Monitoring | Yes | |
| Communications & Management | ||
| Network Management | Built-In | |
| Web Management | Yes | |
| SNMP Management | Yes | |
| Telnet Management | Yes | |
| Remote PDU Monitoring | Yes | |
| Remote PDU Configuration | Yes | |
| Remote Outlet Control | Yes | |
| Individual Outlet ON/OFF | Yes | |
| Remote Power Cycling | Yes | |
| Power Sequencing Management | Yes | |
| Load Shedding Management | Yes | |
| User-Defined Alarms | Yes | |
| Environmental Monitoring | Supported | |
| Temperature / Humidity Sensor Port | Yes | |
| APC Centralized Management Support | Yes | |
| InfraStruxure Central Support | Yes | |
| Capacity Manager Support | Yes | |
| Change Manager Support | Yes | |
| Local Configuration | Serial Configuration Interface | |
| Serial Configuration Cable | Included | |
| Important – Network Card | No Optional Network Management Card Required – Network Management is Built Into the PDU | |
| Power Management Features | ||
| Metered by Outlet | Yes | |
| Switched Outlets | Yes | |
| Individual Outlet Control | Yes | |
| Individual Outlet Metering | Yes | |
| Remote Equipment Reboot | Yes | |
| Power Sequencing | Yes | |
| Configurable Power-Up Delays | Yes | |
| Configurable Power-Down Delays | Yes | |
| Load Shedding | Yes | |
| Load Prioritization | Yes | |
| Real-Time Remote Load Monitoring | Yes | |
| Overload Alarm Capability | Yes | |
| Physical | ||
| Primary Form Factor | Vertical Rack PDU | |
| Rack Height | ZeroU | |
| Mounting Mode | Rack-Mounted | |
| Mounting Position | Vertical | |
| Mounting Location | Side | |
| Color | Black | |
| Height | 72.008 in (1829 mm) | |
| Width | 2.2 in (56 mm) | |
| Depth | 2.008 in (51 mm) | |
| Net Weight | 14.93 lb (6.77 kg) | |
| Shipping Height | 80.2 in (203.8 cm) | |
| Shipping Width | 4.6 in (11.7 cm) | |
| Shipping Depth | 6.4 in (16.2 cm) | |
| Shipping Weight | 19.95 lb (9.05 kg) | |
| Environmental | ||
| Operating Temperature | 23–140°F (-5–60°C) | |
| Storage Temperature | -13–149°F (-25–65°C) | |
| Operating Relative Humidity | 5–95% | |
| Storage Relative Humidity | 5–95% | |
| Operating Altitude | 0–10,000 ft (0–3,048 m) | |
| Storage Altitude | 0–50,000 ft (0–15,240 m) | |
| Conformance | ||
| Product Certifications | UL Listed, VCCI Class A, VDE | |
| Standards | EN 55022 Class A | |
| EN 55024 | ||
| EN 61000-3-2 | ||
| EN 61000-3-3 | ||
| FCC Part 15 Class A | ||
| ICES-003 | ||
| Condition & Warranty | ||
| Condition | Refurbished PDU | |
| Warranty | 1 Year Full Replacement Warranty | |
| Additional Warranty | Available |