APC Rack PDU 2G Switched By Outlet, Zero U, 30A, 200/208V
Model: AP8941
Input: 200V / 208V / 230V, 30A
Input Connections: NEMA L6-30P (200/208V - 30A)
Output Connections: (21) IEC 60320 C13, (3) IEC 60320 C19
Output: 200V, 208V
Maximum Load Capacity: 4992VA
Individual Outlet Switching & Remote Reboot
Integrated Web, SNMP & CLI Network Management
Real-Time Power & Energy Monitoring
Environmental Monitoring Port
Refurbished PDU
1 Year Full Replacement Warranty Included
In stock
Manufacturer: APC
Model: APC Rack PDU 2G, Switched, Zero U, 30A, 200/208V
Condition: Refurbished PDU
Part Number: AP8941
Maximum Load Capacity: 4992VA
Input: NEMA L6-30P, 200/208V, 30A
Output: (21) IEC C13, (3) IEC C19
PDU Type: Switched - Individual Outlet Control
Network Management: Integrated Web, SNMP & CLI Management
Environmental Monitoring: Supports AP9335T / AP9335TH Sensors
Form Factor: Vertical Zero U
Warranty: 1 Year Full Replacement Warranty
Description:Â The APC AP8941 is a switched 0U rack PDU designed to provide advanced remote power management and reliable power distribution for high-density IT environments. Operating at 200/208V with a NEMA L6-30P input, the AP8941 provides (21) IEC C13 and (3) IEC C19 outlets with individual outlet-level switching and monitoring. Built-in network management supports Web, SNMP, and CLI access, allowing remote outlet control, power sequencing, load monitoring, energy metering, and alarm notifications. An environmental monitoring port supports optional APC temperature and humidity sensors. Refurbished and backed by a 1 Year Full Replacement Warranty.
Â
Â
Â
Â
Â
APC AP8941 Rack PDU 2G, Switched, Zero U - User Manual
Â
Â
AP8941 Specifications Rack PDU 2G Switched By Outlet :
| Main | Â | Â |
| Manufacturer | APC | Â |
| Product Series | Rack PDU 2G | Â |
| Model / Part Number | AP8941 | Â |
| Product Type | Switched Rack Power Distribution Unit (PDU) | Â |
| PDU Type | Switched | Â |
| Form Factor | Vertical Zero U | Â |
| Main Input Voltage | 200V / 208V / 230V | Â |
| Output Voltage | 200V / 208V | Â |
| Maximum Load Capacity | 4992VA | Â |
| Rated Input Current | 24A | Â |
| Maximum Line Current | 30A | Â |
| Input Connection | NEMA L6-30P | Â |
| Total Outlets | 24 | Â |
| Output Connections | (21) IEC 60320 C13, (3) IEC 60320 C19 | Â |
| Network Management | Integrated | Â |
| Individual Outlet Switching | Yes | Â |
| Remote Monitoring | Yes | Â |
| Environmental Monitoring | Yes - Optional Sensor Required | Â |
| Rack Space Required | 0U | Â |
| Â | Â | Â |
| Input | Â | Â |
| Input Voltage | 200V / 208V / 230V | Â |
| Input Connection Type | NEMA L6-30P | |
| Network Frequency | 50/60 Hz | Â |
| Rated Input Current | 24A | Â |
| Maximum Line Current | 30A | Â |
| Input Current Limit | 30A | Â |
| Number of Power Cords | 1 | Â |
| Cord Length | 9.8 ft (3 m) | Â |
| Â | Â | Â |
| Output | Â | Â |
| Output Voltage | 200V / 208V | Â |
| Maximum Load Capacity | 4992VA | Â |
| Maximum Current Draw | 30A | Â |
| Total Number of Outlets | 24 | Â |
| IEC C13 Outlets | (21) IEC 60320 C13 | |
| IEC C19 Outlets | (3) IEC 60320 C19 | |
| Outlet Control | Individual Outlet Switching | Â |
| Remote Outlet On / Off | Yes | Â |
| Remote Outlet Reboot | Yes | Â |
| Power-On Sequencing | Supported with Configurable Time Delays | Â |
| Outlet Grouping | Supported | Â |
| Multi-PDU Outlet Grouping | Supported | Â |
| Protection Type | Circuit Breaker | Â |
| Overload Recovery | Designed for Quick Recovery from Overload Events | Â |
| Circuit Breaker Design | Ultra-Low-Profile Breakers | Â |
| Â | Â | Â |
| Metering & Power Monitoring | Â | Â |
| Real-Time Monitoring | Yes | Â |
| Current Monitoring | Yes | Â |
| Voltage Monitoring | Yes | Â |
| Real Power Monitoring | Yes - kW | Â |
| Energy Monitoring | Yes - kWh | Â |
| Load Monitoring | Yes | Â |
| Remote Metering | Yes | Â |
| Historical Metering | Embedded Log Memory | Â |
| Energy Usage Monitoring | Yes | Â |
| Overload Monitoring | Yes | Â |
| User-Defined Load Alarms | Supported | Â |
| Local Metering Display | Current, Power and Voltage Measurements | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Network Management | Integrated Network Management Interface | Â |
| Ethernet Network Management | Integrated | Â |
| Web Management | Supported | Â |
| SNMP Management | Supported | Â |
| Command Line Interface | Supported | Â |
| Remote PDU Management | Supported | Â |
| Remote Outlet Control | Individual Outlet On / Off Control | Â |
| Remote Reboot | Supported | Â |
| Power Sequencing | Supported | Â |
| Outlet Group Management | Supported | Â |
| Multi-PDU Outlet Grouping | Supported | Â |
| Real-Time Remote Monitoring | Supported | Â |
| User-Defined Alarms | Supported | Â |
| Event / Data Logging | Embedded Memory Log | Â |
| Historical Metering Data | Supported | Â |
| Local Configuration | Supported | Â |
| Serial Configuration | Supported | Â |
| Serial Configuration Cable | Included with Original APC Package | Â |
| Environmental Monitoring Port | Yes | Â |
| Compatible Temperature Sensor | AP9335T | Â |
| Compatible Temperature / Humidity Sensor | AP9335TH | Â |
| Environmental Sensor Requirement | Optional - Sensor Sold Separately | Â |
| USB Compatibility | No | Â |
| Â | Â | Â |
| User Interface, Alerts & Controls | Â | Â |
| Local Display | Integrated Local Display | Â |
| Local Monitoring | Displays Current, Power and Voltage Measurements | Â |
| Local User Access | Supported | Â |
| Remote User Access | Supported through Network Management Interface | Â |
| Outlet Control | Individual Remote On / Off | Â |
| Power Sequencing Control | Configurable Time Delays | Â |
| Outlet Group Control | Supported | Â |
| User-Defined Alarms | Supported | Â |
| Overload Warning | Real-Time Load Monitoring and User-Defined Alarms | Â |
| Event History | Embedded Memory Log | Â |
| Energy Data | kW and kWh Monitoring | Â |
| Â | Â | Â |
| Power Management Features | Â | Â |
| Individual Outlet Switching | Yes | Â |
| Individual Outlet Reboot | Yes | Â |
| Remote Power Cycling | Yes | Â |
| Power-On Sequencing | Yes | Â |
| Configurable Sequencing Delays | Yes | Â |
| Outlet Grouping | Yes | Â |
| Outlet Grouping Across Multiple APC PDUs | Yes | Â |
| Load Management | Advanced Outlet-Level Load Management | Â |
| Overload Prevention | Real-Time Monitoring and User-Defined Alarm Thresholds | Â |
| Energy Management | Voltage, Current, Real Power and Energy Monitoring | Â |
| Network Manageable | Yes - Integrated | Â |
| Environmental Monitoring | Optional Temperature / Humidity Sensors | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Color | Black | Â |
| Form Factor | Vertical Zero U | Â |
| Rack Units | 0U | Â |
| Height | 72.008 in (1829 mm) | Â |
| Width | 2.2 in (56 mm) | Â |
| Depth | 1.8 in (46 mm) | Â |
| Dimensions (H × W × D) | 72.008 × 2.2 × 1.8 in |  |
| Net Weight | 16.84 lb (7.64 kg) | Â |
| Mounting Position | Vertical | Â |
| Mounting Location | Side | Â |
| Mounting Preference | No Preference | Â |
| APC NetShelter Installation | Toolless Installation Supported in Compatible APC NetShelter Enclosures | Â |
| Rack Space Consumption | 0U | Â |
| USB Compatible | No | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 23–140°F (-5–60°C) |  |
| Storage Temperature | -13–149°F (-25–65°C) |  |
| Operating Relative Humidity | 5–95% |  |
| Storage Relative Humidity | 5–95% |  |
| Operating Altitude | 0–10,000 ft |  |
| Storage Altitude | 0–50,000 ft (0–15,240 m) |  |
| Â | Â | Â |
| Conformance | Â | Â |
| Product Certifications | cUL Listed, PSE, UL Listed, VCCI Class A | Â |
| FCC Compliance | FCC Part 15 Class A | Â |
| ICES Compliance | ICES-003 | Â |
| EU RoHS | Compliant by Exemption | Â |
| Â | Â | Â |
| Packaging | Â | Â |
| Package Type | PCE | Â |
| Units per Package | 1 | Â |
| Package Height | 80.3 in (204 cm) | Â |
| Package Width | 4.9 in (12.4 cm) | Â |
| Package Length | 6.5 in (16.5 cm) | Â |
| Package Weight | 22.05 lb (10 kg) | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | Refurbished PDU | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |
Â