APC AP8965 Rack PDU, 8600W, Switched, 30A, 208V - 3 Phase
Model: AP8965
Input: 208V 3PH
Input Connections: NEMA L21-30P
Output:Â 208V
Output Connections: (21) C13, (3) C19
Refurbished PDU
1 Year Replacement Warranty
In stock
Manufacturer: APC
Model Description:Â APC 8.6kW Switched Rack PDU 2G, ZeroU, 3PH, 30A 208V, (16)C13
Condition: Refurbished
Part Number: AP8965
Output Voltage:Â 208V
Input Voltage:Â 208V 30A
Warranty: 1 Year Full Replacement Warranty
Description: Â APC AP8965 Switched Rack PDU 2G ZeroU 8.6kW 208V 3PH (16)C13 (3)C19 is a high-capacity vertical power distribution unit (PDU) designed for data center racks, featuring a 208V 30A three-phase input via NEMA L21-30P connector, delivering up to 8600VA of total capacity, with multiple IEC C13 and C19 outlets to support various equipment, built-in overload protection, and advanced remote monitoring and individual outlet control (switched), housed in a robust 0U form factor for space-saving installation without occupying rack units, making it ideal for high-density and mission-critical environments, includes a 1-year warranty and refurbished condition.
Â
Â
APC AP8965 Rack PDU, 8600W, Switched, 30A - User Manual
AP8965 Specifications:
Key Features:
|
Output Connections |
|
||||
|
Nominal Output Voltage |
208V |
||||
|
Nominal Input Voltage |
208V 3PH |
||||
|
Input Connections |
NEMA L21-30P |
||||
|
Cord Length |
6ft (1.8 meters) |
Output:
|
Overload Protection |
Yes |
|
Maximum Total Current Draw |
30 |
Input:
|
Input frequency |
50/60 Hz |
|
Number of Power Cords |
1 |
|
Load Capacity |
8600VA |
|
Maximum Input Current |
30A |
|
Maximum Line Current |
30A |
|
Regulatory Derated Input Current (North America) |
24A |
Physical:
|
Maximum Height |
72.01 inches (1829mm, 182.9cm) |
|
Maximum Width |
2.2 inches (56mm, 5.6cm) |
|
Maximum Depth |
2.01 inches (51mm, 5.1cm) |
|
Net Weight |
18.03 lbs. (8.18 kg) |
|
Color |
Black |
Environmental:
|
Operating Temperature |
23 - 140°F (-5 - 60°C) |
|
Operating Relative Humidity |
5 - 95% |
|
Operating Elevation |
0 - 10000ft (0 - 3048 meters) |
|
Storage Temperature |
-25 - 65°C |
|
Storage Relative Humidity |
5 - 95% |
|
Storage Elevation |
0 - 50000ft (0 - 15240 meters) |
Â
Communications & Management:
|
Control Panel |
No local display; management via web interface (Network Management Card) |
|
Remote Monitoring |
Yes, full remote monitoring and control via network interface |
|
Communication Protocols |
SNMP v1/v2c/v3, HTTP/HTTPS, Telnet, SSH, FTP, SCP |
|
Network Interface |
10/100 Ethernet port (built-in Network Management Card 2) |
|
Outlet Control |
Individual outlet switching (remote on/off/reboot per outlet) |
|
Emergency Power Off (EPO) |
Not supported |
|
Alarm |
Configurable alarms for overload, threshold breaches, and network events |
|
Notifications |
SNMP traps, email alerts, syslog notifications |
|
Alarm Types |
Network-based alerts (email, SNMP, syslog) |
|
Load Monitoring |
Real-time current monitoring (per phase and total load) |
|
Logging |
Event logs and power usage data via web interface |
|
Firmware Upgrade |
Supported via web interface (NMC2) |
|
 |
 |
Â
Â