APC Back-UPS NS 1080VA 650W 120V 15A Output: (8)5-15R, BN1080G - Refurbished

APC Back-UPS NS 1080VA 650W
Model: BN1080G
Input: NEMA 5-15P (120V - 15A)
Output: (4) NEMA 5-15R (Surge Protection), (4) NEMA 5-15R (Battery Backup)
Line Interactive UPS - Stepped Approximation to a sine wave
New batteries, Refurbished UPS
1 Year Warranty Included

In stock

Manufacturer: APC
Model:
 APC Power Saving Back-UPS NS 1080VA 650W Tower, 120V
Condition:
New Batteries, Refurbished UPS
Part Number:
BN1080G

Maximum output: 650W / 1080VA
Typical backup time at half load:
13 minutes (325 Watts)
Typical backup time at full load:
3 minutes (650 Watts)
Warranty:
1 year full replacement warranty


APC Back-UPS NS 1080VA 650W Tower 120V BN1080G Manual


BN1080G - APC Back-UPS NS 1080VA Specifications:

Main:

Main Input Voltage

120V

Rated Power in W

650W

Rated Power in VA

1080VA

Output Connection Type

(4) NEMA 5-15R

(4) NEMA 5-15R (Surge)

Cable Length

6 ft (1.83 m)

Number of Cables

1

Battery Type

Lead-Acid Battery


General:

Number of Power Module Free Slots

0

Number of Power Module Filled Slots

0

Redundant

No


Physical:

Color

Black

Height

9.84 in (25 cm)

Width

3.94 in (10 cm)

Depth

15.04 in (38.2 cm)

Net Weight

23.63 lb(US) (10.72 kg)

Mounting Preference

No Preference

Mounting Mode

Not Rack-mountable

Two Post Mountable

0

USB Compatible

No


Input:

Input Frequency

60 Hz +/- 3 Hz

Efficiency at full load

88 - 139 V

Maximum Input Current per Phase

12A

Switching Current Capacity

15A


Output:

Max Configurable Power (Watts)

650W

Output Frequency (sync to mains)

60 Hz +/- 3 Hz sync to mains

Crest Factor

3 : 1

Topology

Line Interactive

Waveform Type

Stepped approximation to a sinewave

Maximum Configurable Power in VA

1080VA

Transfer Time

8ms typical : 12ms maximum


Conformance:

Product Certifications

California (CEC) Battery Charger
DOC/Industry Cananda
UL Listed


Environmental:

Ambient Air Temperature for Operation

32 - 104°F (0 - 40°C)

Relative Humidity

0 - 95%

Operating Altitude

0 - 9842 ft

Ambient Air Temperature for Storage

5 - 113°F (-15 - 45°C)

Storage Relative Humidity

0 - 95%

Storage Altitude

0 - 49212 ft (0.00 - 14999.82 m)

Acoustic Level

45 dBA


Batteries & Runtime:

Included Battery Modules

0

Battery Slots Empty

0

Typical Recharge Time

16 h

RBC Quantity

1

Battery Charge Power (Watts)

10 W rated

Battery Power in VAH

157 VAh runtime

Battery Life

3 - 5 year(s)

Replacement Battery

APCRBC123

Battery Graph Comments

This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several variables including battery age, battery charge level, environmental conditions and characteristics of the connected load.

Extendable Run Time

0


Communications & Management:

Control Panel

Multi-function LCD status and control console

Alarm

Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm


Surge Protection and Filtering:

Surge Energy Rating

354 J

Filtering

Full time multi-pole noise filtering :5% of IEEE surge let-through : zero clamping response time: in

Data Line Protection

Coaxial cable for CATV/SATV/modem/audio-video

Let Through Voltage Rating

300V