APC Back-UPS XS 1000VA 600W
Model: BX1000
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R (Battery Backup), (2) NEMA 5-15R (Surge Protection)
Line Interactive UPS - Stepped Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: APC
Model: APC Back-UPS XS 1000VA 600W 15A, 120V
Condition: New batteries, refurbished UPS
Part Number: BX1000
Maximum output: 600W / 1000VA
Typical backup time at half load: 18.3 minutes (300 Watts)
Typical backup time at full load: 6.1 minutes (600 Watts)
Warranty: 1 year full replacement warranty
APC Back-UPS XS 1000VA 600W 120V BX1000 Manual
BX1000 - APC Back-UPS XS 1000VA Specifications:
Main:
|
Main Input Voltage |
120V |
||||
|
Kw Rating |
600W |
||||
|
Rated Power in VA |
1000VA |
||||
|
Output Connection Type |
|
||||
|
Number of Rack Unit |
2U |
||||
|
Cable Length |
6 ft (1.83 m) |
||||
|
Number of Cables |
1 |
||||
|
Battery Type |
Lead-Acid Battery |
Batteries & Runtime:
|
Included Battery Modules |
1 |
|
Battery Slots Empty |
0 |
|
Typical Recharge Time |
8 h |
|
RBC Quantity |
1 |
|
Battery Charge Power (Watts) |
20 W rated |
|
Battery Power in VAH |
164 VAh runtime |
|
Battery Life |
4…6 year(s) |
|
Replacement Battery |
RBC32 |
|
Extendable Run Time |
0 |
General:
|
Number of Power Module Free Slots |
0 |
|
Number of Power Module Filled Slots |
0 |
|
Redundant |
No |
Physical:
|
Color |
Beige |
|
Height |
14.61 in (37.1 cm) |
|
Width |
3.39 in (8.6 cm) |
|
Depth |
13.11 in (33.3 cm) |
|
Net Weight |
22.05 lb(US) (10 kg) |
|
Mounting Location |
Front |
|
Mounting Preference |
No preference |
|
Mounting Mode |
Not rack-mountable |
|
Two Post Mountable |
0 |
|
USB Compatible |
No |
Input:
|
Input Frequency |
47...63 Hz |
|
Efficiency at Full Load |
78...152 V adjustable |
Output:
|
Max Configurable Power (Watts) |
600W |
|
Topology |
Line Interactive |
|
Maximum Output Current |
12A |
|
Maximum Configurable Power in VA |
1000VA |
Conformance:
|
Product Certifications |
cUL Listed
UL Listed |
Environmental:
|
Ambient Air Temperature for Operation |
32…104 °F (0…40 °C)
|
|
Relative Humidity |
0…95% |
|
Operating Altitude |
0...10000 ft |
|
Ambient Air Temperature for Storage |
23…113 °F (-5…45 °C) |
|
Storage Relative Humidity |
0…95% |
|
Storage Altitude |
0…50000 ft (0.00…15240.00 m) |
|
Acoustic Level |
45 dBA |
|
Heat Dissipation |
180 Btu/h |
Communications & Management:
|
Control Panel |
LED status display with on line : on battery : replace battery and overload indicators
|
|
Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays |
Surge Protection & Filtering:
|
Surge Energy Rating |
420 J
|
|
Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : mee |
|
Data Line Protection |
RJ11 modem/fax/DSL protection (two wire single line) |