APC Back-UPS XS 1000VA 600W LCD Tower 120V
Model: BX1000G
Input: 120V - 12A Max Input
Output: (4) NEMA 5-15R Battery Backup + Surge, (4) NEMA 5-15R Surge Only
Line-Interactive UPS - Stepped Approximation to a Sine Wave
Automatic Voltage Regulation (AVR)
Multifunction LCD Status & Control Display
USB Communication & PowerChute Compatible
Power-Saving Master & Controlled Outlets
New Batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: APC
Model: APC Back-UPS XS 1000VA 600W LCD Tower 120V
Condition: New Batteries, Refurbished UPS
Part Number: BX1000G
Maximum Output: 600W / 1000VA
Typical Backup Time at Half Load: 16 Minutes (300W)
Typical Backup Time at Full Load: 4.5 Minutes (600W)
Input: 120V
Output: (4) NEMA 5-15R Battery Backup + Surge, (4) NEMA 5-15R Surge Only
Topology: Line-Interactive
Output Waveform: Stepped Approximation to a Sine Wave
Display: Multifunction LCD Status & Control Display
Warranty: 1 Year Full Replacement Warranty
Â
Â
APC Back-UPS XS 1000VA 600W BX1000G - User Manual
Â
Â
Â
BX1000G - APC Back-UPS XS Specifications:
| Main | Â | Â |
| Manufacturer | APC | Â |
| Product Family | Back-UPS XS | Â |
| Model | BX1000G | Â |
| Product Type | Uninterruptible Power Supply (UPS) | Â |
| Rated Power | 1000VA / 600W | Â |
| Maximum Configurable Power | 1000VA / 600W | Â |
| Main Input Voltage | 120V | Â |
| Topology | Line-Interactive | Â |
| Waveform Type | Stepped Approximation to a Sine Wave | Â |
| Form Factor | Tower | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V | Â |
| Input Frequency | 50/60 Hz Auto-Sensing | Â |
| Online Input Voltage Range | 88–139V |  |
| Maximum Input Current per Phase | 12A | Â |
| Switching Current Capacity | 15A | Â |
| Power Cord Length | 6 ft (1.83 m) | Â |
| Number of Power Cables | 1 | Â |
| Â | Â | Â |
| Output | Â | Â |
| Rated Output Capacity | 1000VA | Â |
| Rated Output Power | 600W | Â |
| Maximum Configurable Power | 1000VA / 600W | Â |
| Battery Backup + Surge Outlets | (4) NEMA 5-15R | |
| Surge-Only Outlets | (4) NEMA 5-15R | |
| Â | Â | Â |
| Total Outlets | (8) NEMA 5-15R | Â |
| Output Frequency | 50/60 Hz synchronized to mains | Â |
| Crest Factor | 3:1 | Â |
| Waveform on Battery | Stepped Approximation to a Sine Wave | Â |
| Maximum Output Current | 15A | Â |
| Transfer Time | 8 ms typical / 12 ms maximum | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Sealed Lead-Acid | Â |
| Replacement Battery | APCRBC123 | Â |
| RBC Quantity | 1 | Â |
| Typical Backup Time at Half Load | 16 minutes (300W) | Â |
| Typical Backup Time at Full Load | 4.5 minutes (600W) | Â |
| Typical Recharge Time | 16 hours | Â |
| Battery Charge Power | 11W rated | Â |
| Battery Capacity | 173 VAh | Â |
| Battery Life | 3–5 years |  |
| Extended Runtime | No | Â |
| Â | Â | Â |
| Voltage Regulation | Â | Â |
| Automatic Voltage Regulation | Yes | Â |
| AVR Function | Compensates for low input voltage | Â |
| Default Sensitivity Input Range | 88–139V |  |
| Low Sensitivity Range | 78–142V |  |
| High Sensitivity Range | 88–136V |  |
| Â | Â | Â |
| Communications & Management | Â | Â |
| USB Communication | Yes | Â |
| Data Port | USB | Â |
| PowerChute Compatible | Yes | Â |
| Network Management Card | No | Â |
| Network Management Slot | No | Â |
| Â | Â | Â |
| User Interface, Alerts & Controls | Â | Â |
| Control Panel | Multifunction LCD Status & Control Console | Â |
| LCD Display | Yes | Â |
| Input Voltage Display | Yes | Â |
| Output Voltage Display | Yes | Â |
| Load Capacity Display | Yes | Â |
| Battery Charge Display | Yes | Â |
| Estimated Runtime Display | Yes | Â |
| Event Counter | Yes | Â |
| AVR Status Indicator | Yes | Â |
| Replace Battery Indicator | Yes | Â |
| Overload Indicator | Yes | Â |
| System Fault Display | Yes | Â |
| Audible Alarm Mute | Yes | Â |
| On-Battery Alarm | Four beeps every 30 seconds | Â |
| Low Battery Alarm | Continuous beeping | Â |
| Overload Alarm | Continuous tone | Â |
| Battery Replacement Alert | Chirps for 1 minute every 5 hours after failed battery diagnostic | Â |
| Manual Self-Test | Yes | Â |
| Automatic Battery Self-Test | Yes | Â |
| Â | Â | Â |
| Power Management Features | Â | Â |
| Power-Saving Function | Yes | Â |
| Master Outlet | Yes | Â |
| Controlled Outlets | Yes | Â |
| Master / Controlled Outlet Control | Yes | Â |
| Adjustable Master Threshold | Yes | Â |
| Adjustable Input Sensitivity | Low / Medium / High | Â |
| Power-Saving LCD Mode | Yes | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Color | Black | Â |
| Height | 9.84 in (25 cm) | Â |
| Width | 3.94 in (10 cm) | Â |
| Depth | 15.04 in (38.2 cm) | Â |
| Net Weight | 23.63 lb (10.72 kg) | Â |
| Mounting Mode | Not Rack-Mountable | Â |
| Form Factor | Tower | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Storage Temperature | 5°F to 113°F (-15°C to 45°C) |  |
| Operating Relative Humidity | 0–95% |  |
| Storage Relative Humidity | 0–95% |  |
| Operating Altitude | 0–9842 ft |  |
| Storage Altitude | 0–49212 ft |  |
| Acoustic Level | 45 dBA | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| Surge Energy Rating | 354 Joules | Â |
| Noise Filtering | Full-Time Multi-Pole Noise Filtering | Â |
| IEEE Surge Let-Through | 5% | Â |
| Clamping Response Time | Zero | Â |
| Let-Through Voltage Rating | 300V | Â |
| Telephone / Network Protection | Yes | Â |
| Coaxial Surge Protection | Yes | Â |
| Â | Â | Â |
| Conformance | Â | Â |
| Product Certifications | DOC / Industry Canada, UL Listed | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |