APC Dell Smart-UPS 3000VA 2700W Rackmount 2U 120V - 30A
Model: DLA3000RM2U
Input: NEMA L5-30P (120V - 30A)
Output: (2) NEMA 5-20R, (2) NEMA 5-15R, (1) NEMA L5-20R
All Outlets - Battery Backup
Line-Interactive UPS - Sine Wave Output
USB & Serial Communications
SmartSlot for Optional Network Management Card
New Batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: APC / Dell
Model: APC Dell Smart-UPS 3000VA 2700W USB & Serial RM 2U 120V
Condition: New Batteries, Refurbished UPS
Part Number: DLA3000RM2U
Maximum Output: 2700W / 3000VA
Typical Backup Time at Half Load: 11.3 Minutes (1350 Watts)
Typical Backup Time at Full Load: 3 Minutes (2700 Watts)
Input: NEMA L5-30P, 120V / 30A
Output: (2) NEMA 5-20R, (2) NEMA 5-15R, (1) NEMA L5-20R - Battery Backup
Topology: Line-Interactive
Output Waveform: Sine Wave
Network Management: Optional via SmartSlot Network Management Card
Management Slot: (1) SmartSlot Available
Communications: USB & Serial
Emergency Power Off (EPO): Yes
Display: LED Status Display with Load & Battery Bar Graphs
Warranty: 1 Year Full Replacement Warranty
Â
Â
Â
APC Dell Smart-UPS 3000VA 2700W USB & Serial RM 2U DLA3000RM2U - User Manual
Â
Â
Â
Â
DLA3000RM2U - APC Dell Smart-UPS Specifications:
| Main | Â | ||||||
| Manufacturer | APC / Dell | ||||||
| Product Family | Smart-UPS | ||||||
| Model | DLA3000RM2U | ||||||
| Product Type | Uninterruptible Power Supply (UPS) | ||||||
| Power Capacity | 3000VA / 2700W | ||||||
| Maximum Configurable Power | 3000VA / 2700W | ||||||
| Main Input Voltage | 120V | ||||||
| Main Output Voltage | 120V | ||||||
| Topology | Line-Interactive | ||||||
| Output Waveform | Sine Wave | ||||||
| Form Factor | Rackmount | ||||||
| Rack Height | 2U | ||||||
| Condition | New Batteries, Refurbished UPS | ||||||
| Warranty | 1 Year Full Replacement Warranty | ||||||
| Â | Â | ||||||
| Input | Â | ||||||
| Nominal Input Voltage | 120V AC | ||||||
| Input Connection | NEMA L5-30P | ||||||
|
Input Connection Type |
|
||||||
| Input Electrical Service | 30A | ||||||
| Input Voltage Range | 82–144V | ||||||
| Adjustable Input Voltage Range | 75–154V | ||||||
| Input Frequency | 50/60 Hz ±3 Hz Auto-Sensing | ||||||
| Input Cord Length | 8 ft (2.4 m) | ||||||
| Number of Input Cords | 1 | ||||||
| Â | Â | ||||||
| Output | Â | ||||||
| Nominal Output Voltage | 120V AC | ||||||
| Maximum Output Power | 2700W | ||||||
| Maximum Output Capacity | 3000VA | ||||||
| Total Output Receptacles | 5 | ||||||
|
Output Connection Type - Battery Backup |
|
||||||
| Battery-Backed Outlets | All (5) Outlets | ||||||
| Output Configuration | (2) NEMA 5-20R + (2) NEMA 5-15R + (1) NEMA L5-20R | ||||||
| Transfer Time | 2 ms Typical | ||||||
| Output Waveform | Sine Wave | ||||||
| UPS Topology | Line-Interactive | ||||||
| Harmonic Distortion | Less Than 5% at Full Load | ||||||
| Output Frequency | 47–53 Hz for 50 Hz Nominal; 57–63 Hz for 60 Hz Nominal, Synchronized to Mains | ||||||
| Â | Â | ||||||
| Voltage Regulation | Â | ||||||
| Automatic Voltage Regulation (AVR) | Yes | ||||||
| Voltage Regulation Method | Line-Interactive AVR | ||||||
| Battery Transfer | Automatic During Out-of-Range Input Conditions | ||||||
| Typical Transfer Time | 2 ms | ||||||
| Â | Â | ||||||
| Batteries & Runtime | Â | ||||||
| Battery Type | Lead-Acid Battery | ||||||
| Replacement Battery | RBC43 | ||||||
| RBC Quantity | 1 | ||||||
| Typical Runtime at Half Load | 11.3 Minutes (1350W) | ||||||
| Typical Runtime at Full Load | 3 Minutes (2700W) | ||||||
| Typical Recharge Time | 3 Hours | ||||||
| Battery Life | 3–5 Years | ||||||
| Battery Power | 528VAh Runtime | ||||||
| Battery Charging Power | 175W Rated | ||||||
| Extendable Runtime | No | ||||||
| Battery Condition | New Batteries | ||||||
| Â | Â | ||||||
| Communications & Management | Â | ||||||
| Local Communications | USB & Serial | ||||||
| USB Interface | Yes | ||||||
| Serial Interface | Yes | ||||||
| Serial Signaling | Smart-UPS RS-232 | ||||||
| Management Expansion Slot | SmartSlot | ||||||
| Free SmartSlot | 1 | ||||||
| Network Management Card | Optional | ||||||
| Remote Network Monitoring | Available with Compatible SmartSlot Network Management Card | ||||||
| Web Management | Available with Compatible Network Management Card | ||||||
| SNMP Management | Available with Compatible Network Management Card | ||||||
| Remote UPS Monitoring | Available with Compatible Network Management Card | ||||||
| Power Management Software | APC PowerChute Compatible | ||||||
| Emergency Power Off (EPO) | Yes | ||||||
| UPS Status Monitoring | Load, Battery, Online, On-Battery, Replace Battery and Overload Status | ||||||
| Audible Alarm | Yes | ||||||
| Configurable Alarm Delays | Yes | ||||||
| Â | Â | ||||||
| User Interface, Alerts & Controls | Â | ||||||
| Front Panel Display | LED Status Display | ||||||
| Load Bar Graph | Yes | ||||||
| Battery Bar Graph | Yes | ||||||
| Online Indicator | Yes | ||||||
| On-Battery Indicator | Yes | ||||||
| Replace Battery Indicator | Yes | ||||||
| Overload Indicator | Yes | ||||||
| Audible On-Battery Alarm | Yes | ||||||
| Low Battery Alarm | Yes | ||||||
| Configurable Alarm Delays | Yes | ||||||
| Emergency Power Off | Yes | ||||||
| Â | Â | ||||||
| Power Management Features | Â | ||||||
| Automatic Voltage Regulation | Yes | ||||||
| Battery Backup | Yes - All (5) Outlets in This Unit Configuration | ||||||
| Sine Wave Output | Yes | ||||||
| Surge Protection | Yes | ||||||
| Noise Filtering | Yes | ||||||
| Network Management Expansion | Yes - SmartSlot | ||||||
| Emergency Power Off | Yes | ||||||
| Â | Â | ||||||
| Physical | Â | ||||||
| Form Factor | Rackmount | ||||||
| Rack Height | 2U | ||||||
| Color | Black | ||||||
| Height | 3.5 in (8.9 cm) | ||||||
| Width | 19.02 in (48.3 cm) | ||||||
| Depth | 26.0 in (66 cm) | ||||||
| Net Weight | 96.21 lb (43.64 kg) | ||||||
| Mounting Location | Front | ||||||
| Mounting Preference | Lower | ||||||
| Mounting Mode | Rack-Mounted | ||||||
| Two-Post Mountable | No | ||||||
| Rack Mounting Support | Rails Supported | ||||||
| Â | Â | ||||||
| Environmental | Â | ||||||
| Operating Temperature | 32–104°F (0–40°C) | ||||||
| Storage Temperature | 5–113°F (-15–45°C) | ||||||
| Operating Relative Humidity | 0–95% | ||||||
| Storage Relative Humidity | 0–95% | ||||||
| Operating Altitude | 0–10,000 ft | ||||||
| Storage Altitude | 0–50,000 ft (0–15,240 m) | ||||||
| Acoustic Level | 47 dBA | ||||||
| Heat Dissipation | 400 BTU/hr | ||||||
| Â | Â | ||||||
| Surge Protection & Filtering | Â | ||||||
| Surge Energy Rating | 480 Joules | ||||||
| Noise Filtering | Full-Time Multi-Pole Noise Filtering | ||||||
| IEEE Surge Let-Through | 0.3% | ||||||
| Clamping Response Time | Zero | ||||||
| Surge Standard | Meets UL 1449 | ||||||
| Â | Â | ||||||
| Conformance | Â | ||||||
| BSMI | Certified | ||||||
| CSA | Certified | ||||||
| Â | Â | ||||||
| Condition & Warranty | Â | ||||||
| UPS Condition | Refurbished | ||||||
| Battery Condition | New Batteries | ||||||
| Warranty | 1 Year Full Replacement Warranty |