APC Smart-UPS RT 3000VA 2100W 208V Tower
Model: SURT3000XLT
Input: NEMA L6-30P (208V - 30A)
Output: (2) L6-30R, (2) L6-20R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: APC
Model:Â APC Smart-UPS RT 3000VA 2100W 208V
Condition: New batteries, refurbished UPS
Part Number: SURT3000XLT
Maximum output: 2100WÂ /Â 3000VA
Typical backup time at half load: 33.9 minutes (1050 Watts)
Typical backup time at full load: 14.1 minutes (2100 Watts)
Warranty: 1 year full replacement warranty
APC Smart-UPS RT 3000VA 2100W SURT3000XLT - User Manual
SURT3000XLT - APC Smart-UPS RT Specifications:
Main:
|
Main Input Voltage |
208V |
||||
|
Other Input Voltage |
240V |
||||
|
Main Output Voltage |
208V |
||||
|
Other Output Voltage |
240V |
||||
|
Rated Power in W |
2100W |
||||
|
Rated Power in VA |
3000VA |
||||
|
Input Connection Type |
|
||||
|
Output Connection Type |
|
||||
|
Number of Rack Unit |
3U |
||||
|
Cable Length |
3.05 m |
||||
|
Number of Cables |
1 |
||||
|
Battery Type |
Lead-Acid battery |
Batteries & Runtime:
|
Number of Battery Filled Slots |
2 |
|
Battery Recharge Time |
2.5 h |
|
Number of Battery Replacement Quantity |
1 |
|
Additional Information |
Configurable for 208 or 240 nominal output voltage |
|
Battery Charger Power |
382 W rated |
|
Battery Power in VAH |
960 VAh runtime |
|
Battery Life |
3 - 5 year(s) |
|
Replacement Battery |
APCRBC140 |
|
Battery Option |
SURT192XLBP 1 2880 VAh |
|
Extended Runtime |
1 |
General:
|
Number of Power Module Free Slots |
0 |
|
Number of Power Module Filled Slots |
0 |
|
Redundant |
No |
Physical:
|
Colour |
Black
|
|
Height |
43.2 cm |
|
Width |
13 cm |
|
Depth |
66 cm |
|
Net Weight |
54.55 kg |
|
Mounting Location |
Front |
|
Mounting Preference |
Lower |
|
Mounting Mode |
Not rack-mountable |
|
USB Compatible |
No |
Input:
|
Network Frequency |
50/60 Hz +/- 5 Hz auto-sensing
|
|
Input Voltage Limits |
160 - 280 V |
Output:
|
Maximum Configurable Power in W |
2100W
|
|
Harmonic Distortion |
Less than 3 % |
|
Output Frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains |
|
Crest Factor |
3 : 1 |
|
UPS Type |
Double conversion online |
|
Wave Type |
Sine wave |
|
Bypass Type |
Internal bypass (automatic and manual) |
|
Efficiency |
91 % (full load) |
|
Maximum configurable power in VA |
3000VA |
Conformance:
|
Product Certifications |
CSA
|
Environmental:
|
Ambient Air Temperature for Operation |
32 - 104°F (0 - 40°C)
|
|
Relative Humidity |
0 - 95% |
|
Operating Altitude |
0 - 10000ft (0 - 3048 meters) |
|
Ambient Air Temperature for Storage |
-15 - 45°C |
|
Storage Relative Humidity |
0 - 95% |
|
Storage altitude |
0 - 50000ft (0 - 15240meters) |
|
Acoustic Level |
55 dBA |
|
Heat Dissipation |
655 Btu/h |
Communications & Management:
|
Free Slots |
1 |
|
Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
|
Emergency Power Off |
Yes |
|
Interface Port(s) |
DB-25 RS-232, Smart-Slot |
Surge Protection and Filtering:
|
Surge Energy Rating |
480 J |
|
Noise suppression |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |