APC Smart-UPS X LCD 2000VA 1800W RM 2U 20A
Model: SMX2000RMLV2U
Input: NEMA 5-20P (120V - 20A)
Output: (3) NEMA 5-15R, (3) NEMA 5-20R, (1) NEMA L5-20R
Output Capacity: 2000VA Class / 1800W
Line-Interactive UPS - Pure Sine Wave Output
Automatic Voltage Regulation (AVR)
Expandable Runtime with External Battery Packs
New Batteries, Refurbished UPS
1 Year Full Replacement Warranty
In stock
Manufacturer: APC
Model: APC Smart-UPS X 2000VA 1800W, RM, 2U, 120V, 20A
Condition: New Batteries, Refurbished UPS
Part Number: SMX2000RMLV2U
Maximum Output: 1800W / 1920VA (2000VA Class)
Typical Backup Time at Half Load: 27.6 Minutes (900W)
Typical Backup Time at Full Load: 10.9 Minutes (1800W)
Input: NEMA 5-20P, 120V AC, 20A, 8 ft Power Cord
Output: (3) NEMA 5-15R, (3) NEMA 5-20R, (1) NEMA L5-20R
Topology: Line-Interactive
Output Waveform: Pure Sine Wave
Automatic Voltage Regulation: Yes (AVR)
Expandable Runtime: Yes, Compatible with SMX120RMBP2U External Battery Packs
Network Management: Optional SmartSlot Network Management Card (Not Included)
Warranty: 1 Year Full Replacement Warranty
Â
Â
Â
APC Smart-UPS X 2000VA 1800W SMX2000RMLV2U - User Manual
Â
Â
Â
SMX2000RMLV2U - APC Smart-UPS X Specifications:
| Main | Â | Â |
| Manufacturer | APC | Â |
| Model | SMX2000RMLV2U | Â |
| Product Family | Smart-UPS X | Â |
| Product Type | Uninterruptible Power Supply (UPS) | Â |
| UPS Topology | Line-Interactive | Â |
| Form Factor | Rackmount / Tower | Â |
| Rack Height | 2U | Â |
| Maximum Output Capacity | 1800W / 1920VA (2000VA Class) | Â |
| Main Input Voltage | 120V AC | Â |
| Other Input Voltages | 100V / 110V / 127V | Â |
| Main Output Voltage | 120V AC | Â |
| Other Output Voltages | 100V / 110V / 127V | Â |
| Input Connection | NEMA 5-20P | Â |
| Output Connections | (3) NEMA 5-15R, (3) NEMA 5-20R, (1) NEMA L5-20R | Â |
| Total Output Receptacles | 7 | Â |
| Input Power Cord Length | 8 ft (2.44 m) | Â |
| Number of Input Cords | 1 | Â |
| Battery Type | Sealed Lead-Acid | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V AC | Â |
| Configurable Input Voltage | 100V / 110V / 120V / 127V AC | Â |
| Input Voltage Range | 70–153V AC |  |
| Adjustable Input Voltage Range | 75–154V AC |  |
| Input Frequency | 50/60 Hz ±3 Hz, Auto-Sensing |  |
| Input Phase | Single-Phase | Â |
| Input Connection Type | NEMA 5-20P | |
| Input Cord Length | 8 ft (2.44 m) | Â |
| Number of Input Cords | 1 | Â |
| Automatic Voltage Regulation | Yes | Â |
| Â | Â | Â |
| Output | Â | Â |
| Rated Output Capacity | 1920VA | Â |
| Commercial Capacity Class | 2000VA | Â |
| Rated Output Power | 1800W | Â |
| Maximum Configurable Power | 1920VA | Â |
| Maximum Configurable Power (Watts) | 1800W | Â |
| Nominal Output Voltage | 120V AC | Â |
| Configurable Output Voltage | 100V / 110V / 120V / 127V AC | Â |
| Output Frequency | 50/60 Hz ±3 Hz, Synchronized to Mains |  |
| Output Waveform | Pure Sine Wave | Â |
| Harmonic Distortion | Less Than 5% | Â |
| UPS Topology | Line-Interactive | Â |
| Typical Transfer Time | 4 ms | Â |
| Maximum Transfer Time | 8 ms | Â |
| Total Output Receptacles | 7 | Â |
| Â | (3) NEMA 5-15R | |
| Output Connection Type | (3) NEMA 5-20R | |
| Â | (1) NEMA L5-20R | |
| Switched Outlet Groups | 3 Controllable Outlet Groups | Â |
| Switched Outlet Group Management | Configurable Shutdown, Restart, Sleep, and Load Shedding | Â |
| Battery Backup Outlets | All Output Receptacles | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Maintenance-Free Sealed Lead-Acid | Â |
| Replacement Battery Cartridge | APCRBC117 | Â |
| Replacement Battery Cartridge Quantity | 1 | Â |
| Battery Module Voltage | 120V DC | Â |
| Battery Capacity | 690 VAh | Â |
| Battery Charge Power | 229W Rated | Â |
| Typical Runtime at Half Load | 27.6 Minutes (900W) | Â |
| Typical Runtime at Full Load | 10.9 Minutes (1800W) | Â |
| Typical Recharge Time | 3 Hours | Â |
| Typical Battery Life | 3–5 Years |  |
| User-Replaceable Batteries | Yes | Â |
| Battery Self-Test | Automatic and Configurable | Â |
| Battery Replacement Notification | Yes | Â |
| Battery Status Monitoring | Yes | Â |
| Estimated Remaining Runtime Display | Yes | Â |
| Expandable Runtime | Yes | Â |
| Compatible External Battery Pack | SMX120RMBP2U | Â |
| Maximum External Battery Packs | Up to 10 | Â |
| Battery Capacity with 1 External Pack | 2070 VAh | Â |
| Battery Capacity with 2 External Packs | 3450 VAh | Â |
| Battery Capacity with 3 External Packs | 4830 VAh | Â |
| Battery Capacity with 4 External Packs | 6210 VAh | Â |
| Battery Capacity with 6 External Packs | 8970 VAh | Â |
| Battery Capacity with 8 External Packs | 11730 VAh | Â |
| Battery Capacity with 10 External Packs | 14490 VAh | Â |
| External Battery Packs Included | No | Â |
| Â | Â | Â |
| Voltage Regulation | Â | Â |
| Automatic Voltage Regulation (AVR) | Yes | Â |
| Adjustable High Transfer Point at 120V | 127–136V AC |  |
| Adjustable Low Transfer Point at 120V | 97–106V AC |  |
| Input Power Quality Settings | Good / Fair / Poor | Â |
| UPS Sensitivity Settings | Normal / Reduced / Low | Â |
| Green Mode | Supported | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Control Panel | Multifunction LCD Status and Control Console | Â |
| LCD Display | Yes | Â |
| LCD Menu Modes | Standard and Advanced | Â |
| Input Voltage Monitoring | Yes | Â |
| Output Voltage Monitoring | Yes | Â |
| Battery Charge Display | Yes | Â |
| Estimated Runtime Display | Yes | Â |
| Load Capacity Display | Yes | Â |
| Battery Voltage Monitoring | Yes | Â |
| UPS Operating Mode Display | Yes | Â |
| Event Log | Yes | Â |
| Battery Self-Test | Yes | Â |
| Runtime Calibration Test | Yes | Â |
| USB Communication | Yes | Â |
| Serial Communication | Yes | Â |
| Simultaneous USB and Serial Operation | No | Â |
| Network Management Expansion Slot | 1 SmartSlot | Â |
| Network Management Card | Optional, Not Included | Â |
| Network Monitoring | Supported with Compatible Optional Management Card | Â |
| Management Software | APC PowerChute | Â |
| Automatic System Shutdown | Supported with Compatible Software | Â |
| Emergency Power Off (EPO) | Yes | Â |
| Switched Outlet Group Control | Yes | Â |
| Configurable Audible Alarms | Yes | Â |
| Online LED Indicator | Yes | Â |
| On Battery LED Indicator | Yes | Â |
| Replace Battery LED Indicator | Yes | Â |
| Fault Indicator | Yes | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| Surge Energy Rating | 540 Joules | Â |
| EMI/RFI Filtering | Full-Time Multi-Pole Noise Filtering | Â |
| IEEE Surge Let-Through | 0.3% | Â |
| Surge Clamping Response Time | Zero | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Color | Black | Â |
| Primary Form Factor | Rackmount | Â |
| Additional Form Factor | Tower | Â |
| Rack Height | 2U | Â |
| Height | 3.36 in (85 mm) | Â |
| Width | 17.0 in (432 mm) | Â |
| Depth | 26.26 in (667 mm) | Â |
| Net Weight | 84.6 lbs (38.45 kg) | Â |
| Mounting Mode | Rack-Mounted | Â |
| Mounting Location | Front | Â |
| Mounting Preference | Lower | Â |
| Two-Post Mountable | No | Â |
| USB Compatible | Yes | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Storage Temperature | 5°F to 113°F (-15°C to 45°C) |  |
| Operating Relative Humidity | 0–95%, Non-Condensing |  |
| Storage Relative Humidity | 0–95% |  |
| Maximum Operating Altitude | 10,000 ft (3,000 m) | Â |
| Maximum Storage Altitude | 50,000 ft (15,240 m) | Â |
| Acoustic Level | 55 dBA | Â |
| Heat Dissipation | 203 BTU/hr | Â |
| International Protection Rating | IP20 | Â |
| Pollution Degree | 2 | Â |
| Overvoltage Category | II | Â |
| Â | Â | Â |
| Conformance | Â | Â |
| Product Certifications | BSMI, CSA, NOM, TÜV, VCCI Class A |  |
| Applicable Safety Standard | IEC 62040-1 | Â |
| FCC Classification | Class A | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |