APC Smart-UPS XL 3000VA 2400W RM 3U 120V
Model: SU3000RMXL3U
Input: NEMA L5-30P (120V - 30A)
Output: (6) NEMA 5-15R, (2) NEMA 5-20R
Line-Interactive UPS - Pure Sine Wave Output
Extended Runtime Capable
SmartSlot Expansion Slot
New Batteries, Refurbished UPS
1 Year Full Replacement Warranty Included
In stock
Manufacturer: APC
Model:Â APC Smart-UPS XL 3000VA 2400W RM 3U 120V
Condition: New Batteries, Refurbished UPS
Part Number: SU3000RMXL3U
Maximum output: 2400WÂ /Â 3000VA
Typical backup time at half load: 18.7 minutes (1200 Watts)
Typical backup time at full load: 5.7 minutes (2400 Watts)
Warranty: 1 Year Full Replacement Warranty
Description: The APC SU3000RMXL3U Smart-UPS XL is a line-interactive rackmount UPS designed to provide reliable power protection for servers, network switches, storage devices, VoIP systems, and critical IT equipment. Delivering 3000VA / 2400W of pure sine wave output power, it features Automatic Voltage Regulation (AVR), hot-swappable batteries, SmartSlot expansion for optional network management, and support for external SU48R3XLBP battery packs to extend runtime. Its 3U rackmount design, intelligent battery management, and enterprise-class reliability make it an ideal solution for business, server room, and network infrastructure applications.
Â
Â
APC Smart-UPS XL 3000VA 2400W RM 3U SU3000RMXL3U - User Manual
Â
Â
SU3000RMXL3U - APC Smart-UPS XL 3000VA Specifications:
| Main | Â | Â |
| Main Input Voltage | 120V | Â |
| Main Output Voltage | 120V | Â |
| Rated Power in W | 2400W | Â |
| Rated Power in VA | 3000VA | Â |
| Input Connection Type | NEMA L5-30P | |
| Output Connection Type |
(6) NEMA 5-15R |
|
| Â |
(2) NEMA 5-20R |
|
| Number of Rack Unit | 3U | Â |
| Cable Length | 8 ft (2.44 m) | Â |
| Number of Cables | 1 | Â |
| Battery Type | Lead-Acid Battery | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Extended Runtime Support | Yes | Â |
| Battery Recharge Time | 3 Hours | Â |
| Battery Life | 3-5 Years | Â |
| Replacement Battery | RBC27 | Â |
| Battery Replacement Quantity | 1 | Â |
| Battery Power | 864 VAh | Â |
| Battery Charger Power | 287W Rated | Â |
| Hot-Swappable Batteries | Yes | Â |
| Compatible External Battery Pack |
SU48R3XLBP 1 2016 VAh |
 |
| External Battery Options | Up to 10 × SU48R3XLBP |  |
| Typical Backup Time at Half Load | 18.7 Minutes (1200 Watts) | Â |
| Typical Backup Time at Full Load | 5.7 Minutes (2400 Watts) | Â |
| Â | Â | Â |
| General | Â | Â |
| UPS Topology | Line Interactive | Â |
| Waveform Type | Pure Sine Wave | Â |
| Maximum Configurable Power | 2400W / 3000VA | Â |
| Maximum Output Current | 15A | Â |
| Crest Factor | Up to 5:1 | Â |
| Harmonic Distortion | Less Than 5% at Full Load | Â |
| Redundant | No | Â |
| Application | Servers, Storage, Network Switches, Telecom and IT Equipment | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Color | Black | Â |
| Height | 5.24 in (13.3 cm) | Â |
| Width | 19.02 in (48.3 cm) | Â |
| Depth | 25.98 in (66 cm) | Â |
| Net Weight | 124.25 lbs (56.36 kg) | Â |
| Mounting Location | Front | Â |
| Mounting Preference | Lower | Â |
| Mounting Mode | Rack-Mounted | Â |
| USB Compatible | No | Â |
| Â | Â | Â |
| Input | Â | Â |
| Input Voltage Limits | 86-154V Adjustable / 92-147V | Â |
| Input Frequency | 50/60 Hz ±3 Hz Auto-Sensing |  |
| Input Phase | Single-Phase | Â |
| Input Connection | NEMA L5-30P | Â |
| Â | Â | Â |
| Output | Â | Â |
| Output Voltage | 120V | Â |
| Maximum Configurable Power in VA | 3000VA | Â |
| Maximum Configurable Power (Watts) | 2400W | Â |
| Maximum Output Current | 15A | Â |
| Output Frequency | 47-53 Hz (50Hz) / 57-63 Hz (60Hz) | Â |
| Waveform Type | Pure Sine Wave | Â |
| Output Connections |
(6) NEMA 5-15R, (2) NEMA 5-20R |
 |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Control Panel | LED Status Display with Load and Battery Bar Graphs | Â |
| Status Indicators | On Line, On Battery, Replace Battery, Overload | Â |
| Communication Port | RS-232 | Â |
| SmartSlot Expansion Slot | 1 | Â |
| Network Management Card Support - Optional |
AP9606, AP9617, AP9618, AP9619 |
 |
| Emergency Power Off (EPO) | Optional | Â |
| Alarm | On Battery, Low Battery and Configurable Delay Alarms | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| Surge Energy Rating | 880 Joules | Â |
| Noise Suppression | Full-Time Multi-Pole Noise Filtering | Â |
| IEEE Surge Let-Through | 0.3% | Â |
| Response Time | Zero Clamping Response Time | Â |
| Compliance | Meets UL 1449 | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Acoustic Level | 53 dBA | Â |
| Heat Dissipation | 375 BTU/hr | Â |
| Operating Altitude | 0-10,000 ft | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Storage Temperature | 5°F to 113°F (-15°C to 45°C) |  |
| Storage Altitude | 0-50,000 ft (15,240 m) | Â |
| Operating Humidity | 0-95% Non-Condensing | Â |
| Storage Humidity | 0-95% Non-Condensing | Â |
| Â | Â | Â |
| Conformance | Â | Â |
| Product Certifications | CSA | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Warranty | 1 Year Full Replacement Warranty Included | Â |