APC Smart-UPS XL 3000VA 2700W RM 3U 120V Â
Model: SUA3000RMXL3U Â
Input: NEMA L5-30P (120V - 30A), 8 ft Cord Â
Output: (9) NEMA 5-15R, (2) NEMA 5-20R Â
Maximum Output: 3000VA / 2700W Â
Line-Interactive UPS - Pure Sine Wave Output Â
Automatic Voltage Regulation (AVR) Â
Compatible with SUA48RMXLBP3U External Battery Packs Â
New Batteries, Refurbished UPS Â
1 Year Full Replacement Warranty Included
In stock
Manufacturer: APC by Schneider Electric
Model: APC Smart-UPS XL 3000VA 2700W RM 3U 120V
Part Number: SUA3000RMXL3U
Condition: New Batteries, Refurbished UPS
Maximum Output: 2700W / 3000VA
Typical Backup Time at Half Load: 16 Minutes (1350W)
Typical Backup Time at Full Load: 6 Minutes (2700W)
Input: NEMA L5-30P, 120V, 30A, 8 ft Power Cord
Output: (9) NEMA 5-15R, (2) NEMA 5-20R
Topology: Line-Interactive with Automatic Voltage Regulation (AVR)
Output Waveform: Pure Sine Wave
Extended Runtime: Compatible with SUA48RMXLBP3U External Battery Packs
Network Management: Optional Network Management Card via SmartSlot
Display: LED Status Indicators with Load and Battery Bar Graphs
Warranty: 1 Year Full Replacement Warranty
Â
Â
Â
APC Smart-UPS XL 3000VA 2700W RM 3U SUA3000RMXL3U - User Manual
Â
Â
Â
Â
SUA3000RMXL3U - APC Smart-UPS XL Specifications:
| Main | Â | Â |
| Manufacturer | APC by Schneider Electric | Â |
| Model | SUA3000RMXL3U | Â |
| Product Family | APC Smart-UPS XL | Â |
| Product Type | Uninterruptible Power Supply (UPS) | Â |
| Rated Output Capacity | 3000VA / 2700W | Â |
| Maximum Configurable Output | 3000VA / 2700W | Â |
| Main Input Voltage | 120V AC | Â |
| Main Output Voltage | 120V AC | Â |
| UPS Topology | Line-Interactive | Â |
| Output Waveform | Pure Sine Wave | Â |
| Automatic Voltage Regulation | Yes, AVR Boost and Trim | Â |
| Form Factor | Rackmount 3U | Â |
| Extended Runtime | Supported | Â |
| Redundant UPS | No | Â |
| Condition | Refurbished UPS with New Batteries | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V AC | Â |
| Input Connection | NEMA L5-30P | Â |
| Input Connection Type | NEMA L5-30PÂ | |
| Input Plug Rating | 30A | Â |
| Input Frequency | 50/60Hz ±3Hz, Auto-Sensing |  |
| Input Voltage Range | 82–144V AC |  |
| Adjustable Input Voltage Range | 75–154V AC |  |
| Input Power Cord Length | 8 ft (2.44 m) | Â |
| Number of Input Cables | 1 | Â |
| Input Phase | Single-Phase | Â |
| Input Circuit Breaker | Yes | Â |
| Site Wiring Fault Indicator | Yes | Â |
| Â | Â | Â |
| Output | Â | Â |
| Rated Output Power | 2700W | Â |
| Rated Output Capacity | 3000VA | Â |
| Maximum Configurable Power | 2700W / 3000VA | Â |
| Nominal Output Voltage | 120V AC | Â |
| Output Frequency | 47–53Hz for 50Hz Nominal; 57–63Hz for 60Hz Nominal |  |
| Output Waveform | Pure Sine Wave | Â |
| Harmonic Distortion | Less Than 5% at Full Load | Â |
| NEMA 5-15R Outlets | (9) NEMA 5-15R | |
| NEMA 5-20R Outlets | (2) NEMA 5-20RÂ | |
| Total Output Receptacles | 11 | Â |
| Transfer Time | 2–4 ms |  |
| Efficiency at Full Load | 95% | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Sealed Lead-Acid | Â |
| Battery Condition | New Batteries | Â |
| Replacement Battery Cartridge | APCRBC105 | Â |
| Replacement Battery Quantity | 1 | Â |
| Typical Backup Time at Half Load | 16 Minutes (1350W) | Â |
| Typical Backup Time at Full Load | 6 Minutes (2700W) | Â |
| Typical Recharge Time | 3 Hours | Â |
| Battery Life | 3–5 Years, Typical |  |
| Battery Energy Rating | 864VAh | Â |
| Battery Charge Power | 287W Rated | Â |
| Hot-Swappable Batteries | Yes | Â |
| Extended Runtime Capability | Yes | Â |
| External Battery Pack Compatibility | SUA48RMXLBP3U | Â |
| Maximum External Battery Packs | Up to 10 | Â |
| External Battery Pack Included | No | Â |
| Â | Â | Â |
| Extended Battery Configuration | Â | Â |
| Internal Battery Only | 864VAh | Â |
| (1) SUA48RMXLBP3U | 2016VAh | Â |
| (2) SUA48RMXLBP3U | 3360VAh | Â |
| (3) SUA48RMXLBP3U | 4704VAh | Â |
| (4) SUA48RMXLBP3U | 6048VAh | Â |
| (6) SUA48RMXLBP3U | 8736VAh | Â |
| (8) SUA48RMXLBP3U | 11424VAh | Â |
| (10) SUA48RMXLBP3U | 14112VAh | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Control Panel | LED Status Display with Load and Battery Charge Bar Graphs | Â |
| LCD Display | No | Â |
| USB Communication | Yes | Â |
| Serial Communication | Yes | Â |
| USB and Serial Simultaneous Operation | No, USB Takes Priority Over Serial | Â |
| SmartSlot Expansion | (1) SmartSlot | Â |
| Available SmartSlot Slots | 1, When No Accessory Card Is Installed | Â |
| Network Management Card | Optional APC SmartSlot Network Management Card, Not Included | Â |
| Ethernet Management | Available with Compatible Optional Network Management Card | Â |
| Web Management | Available with Compatible Optional Network Management Card | Â |
| SNMP Monitoring | Available with Compatible Optional Network Management Card | Â |
| Remote UPS Monitoring | Supported Through Compatible Management Software or Optional SmartSlot Card | Â |
| Remote UPS Shutdown | Supported Through Compatible Management Software or Optional SmartSlot Card | Â |
| PowerChute Software | PowerChute Business Edition Supported | Â |
| Automatic Self-Test | On Startup and Every 14 Days by Default | Â |
| Manual Self-Test | Supported via Front Panel Test Button | Â |
| Configurable Self-Test Interval | Every 7 Days, Every 14 Days, Startup Only, or Disabled | Â |
| Battery Status Monitoring | Supported | Â |
| Load Monitoring | Supported | Â |
| Utility Voltage Monitoring | Supported via LED Diagnostic Indicator | Â |
| Configurable Voltage Sensitivity | High, Medium, or Low | Â |
| Configurable Shutdown Delay | 0–630 Seconds |  |
| Configurable Low Battery Warning | Approximately 2, 5, or 8 Minutes | Â |
| Configurable Alarm Delay | Enable, Mute, or Disable | Â |
| External Battery Pack Configuration | Supported via PowerChute, Compatible Network Management Card, or UPS Terminal Mode | Â |
| Emergency Power Off (EPO) | Integrated EPO Interface; External Switch Connection Supported | Â |
| Â | Â | Â |
| User Interface & Controls | Â | Â |
| Display Type | LED Status Indicators | Â |
| Load Capacity Indicator | LED Bar Graph | Â |
| Battery Charge Indicator | LED Bar Graph | Â |
| Online Indicator | Yes | Â |
| On-Battery Indicator | Yes | Â |
| Replace Battery Indicator | Yes | Â |
| Overload Indicator | Yes | Â |
| AVR Boost Indicator | Yes | Â |
| AVR Trim Indicator | Yes | Â |
| Diagnostic Utility Voltage Indicator | Yes | Â |
| Audible Battery Alarm | Yes | Â |
| Low Battery Alarm | Yes | Â |
| Configurable Alarm Delays | Yes | Â |
| Cold Start Capability | Yes | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| Surge Energy Rating | 880 Joules | Â |
| Noise Filtering | Full-Time Multi-Pole Noise Filtering | Â |
| IEEE Surge Let-Through | 0.3% | Â |
| Clamping Response Time | Zero | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Mounting Type | Rackmount | Â |
| Rack Height | 3U | Â |
| Height | 5.24 in (13.3 cm) | Â |
| Width | 19.02 in (48.3 cm) | Â |
| Depth | 25.98 in (66 cm) | Â |
| Net Weight | 131.29 lbs (59.55 kg) | Â |
| Color | Black | Â |
| Rack Mounting | Supported | Â |
| Mounting Location | Front | Â |
| Mounting Preference | Lower Rack Position | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |  |
| Storage Temperature | -15°C to 45°C (5°F to 113°F) |  |
| Operating Relative Humidity | 0–95%, Non-Condensing |  |
| Storage Relative Humidity | 0–95%, Non-Condensing |  |
| Operating Altitude | 0–10,000 ft |  |
| Storage Altitude | 0–50,000 ft |  |
| Acoustic Noise Level | 53 dBA | Â |
| Heat Dissipation | 375 BTU/hr | Â |
| Â | Â | Â |
| Certifications & Compliance | Â | Â |
| Product Certification | CSA | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| UPS Condition | Refurbished | Â |
| Battery Condition | New Batteries | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |