APC Symmetra LX 8kVA 6.4kW Scalable to 16kVA N+1 208V/240V
Model: SYA8K16PXR - Extended Runtime Tower
Maximum: 6.4kW / 8kVA
Included: (2) 4kVa Power Modules, (9) Battery Modules
Output: (1) Hard Wire 4-wire (2PH + N +G)
New Batteries, Refurbished UPS
1 Year Replacement Warranty
In stock
Manufacturer: APC
Model: APC Symmetra LX 8kVA 6.4kW 208/240V Scalable to 16kVA N+1
Condition: Refurbished with New Batteries
Part Number: SYA8K16PXR
Warranty: 1 Year Full Replacement Warranty, additional warranty available
Runtime at half load: 1.5 minutes @ 3200W
Runtime at full load: 49 minutes @ 6400W
Included: APC Symmetra 16kVA Frame with (2) 4kVA Power Modules, (9) SYBT5 Battery Modules. Configured as an 8kVA 6.4kW UPS.
The APC Symmetra LX 8kVA SYA8K16PXR is configured for 8kVA 6.4kW. The system can be scaled to 16kVA, N+1 if needed.
This extended runtime tower can have an additional 4x battery packs installed for additional run time. The APC Symmetra LX 8kVA comes with a one year replacement warranty. Additional warranty of up to 3 years is available for your convenience.
APC Symmetra LX 8kVA Specifications:
Main:
|
Main Input Voltage |
208V |
|
Other Input Voltage |
240V |
|
Main Output Voltage |
120V |
|
Other Output Voltage |
240V |
|
Kw Rating |
6400W |
|
Rated Power in VA |
8000VA |
|
Output Connector Type |
Hard Wire 4-wire (2PH+N+G) 1 |
|
Battery Type |
Lead-Acid battery |
Batteries & Runtime:
|
Included Battery Modules |
9 |
|
Battery Slots Empty |
4 |
|
Typical Recharge Time |
7.5 h |
|
Additional Information |
Configurable for 120/208 or 120/240 output voltage |
|
Battery Charge Power (Watts) |
1035 W rated |
|
Battery Life |
3…5 year(s) |
|
Replacement Battery |
SYA8K16PX798 |
|
Extendable Run Time |
1 |
General:
|
Product Web Sub-family |
4kVA power increments |
|
Number of Power Module Free Slots |
3 |
|
Number of Power Module Filled Slots |
2 |
|
Redundant |
Yes |
Physical:
|
Color |
Black |
|
Height |
59.69 in (151.6 cm) |
|
Width |
19.02 in (48.3 cm) |
|
Depth |
28.58 in (72.6 cm) |
|
Net Weight |
1044.20 lb(US) (473.64 kg) |
|
Mounting Location |
Front |
|
Mounting Preference |
No preference |
|
Mounting Mode |
Not rack-mountable |
|
Two Post Mountable |
0 |
|
USB Compatible |
No |
Input:
|
Input Frequency |
45...65 Hz auto-sensing |
|
Number of Input Connectors |
1 Hard Wire 4-wire (2PH+N+G) |
|
Efficiency at Full Load |
96...138 V line to neutral |
|
Input Total Harmonic Distortion |
Less than 7% for full load |
|
Input Power Factor at Full Load |
0.98 |
Output:
|
Max Configurable Power (Watts) |
12800W |
|
Harmonic Distortion |
Less than 5 % at full load |
|
Output Frequency (sync to mains) |
47...63 Hz sync to mains |
|
Crest Factor |
Up to 5 : 1 |
|
Topology |
Double Conversion Online |
|
Waveform Type |
Sine wave |
|
Bypass Type |
Internal Bypass (Automatic and Manual) Optional External Bypass |
|
Maximum Output Current |
37 A |
|
Maximum Configurable Power in VA |
16000VA |
Conformance:
|
Product Certifications |
CSA |
|
Standards |
FCC Part 15 class A |
Environmental:
|
Ambient Air Temperature for Operation |
32…104 °F (0…40 °C) |
|
Relative Humidity |
0…95% |
|
Operating Altitude |
0...10000 ft |
|
Ambient Air Temperature for Storage |
5…113 °F (-15…45 °C) |
|
Storage Relative Humidity |
0…95% |
|
Storage Altitude |
0…15000 ft (0.00…4572.00 m) |
|
Acoustic Level |
62 dBA |
|
Heat Dissipation |
4995 Btu/h |
Communications & Management:
|
Free Slots |
1 |
|
Pre-Installed SmartSlot™ Cards |
Network management card 2 with environmental monitoring |
|
Control Panel |
Multi-function LCD status and control console |
|
Alarm |
Audible and visible alarms : prioritized by severity |
|
Emergency Power Off (EPO) |
Yes |