CyberPower Smart App LCD UPS 2000VA 1320W RM 2U 120V 20A
Model: OR2200LCDRT2U
Input: NEMA 5-20P (120V - 20A)
Output: (8) NEMA 5-20R
Line-Interactive UPS - Simulated Sine Wave Output
Automatic Voltage Regulation (AVR)
USB, Serial & Dry Contact Communications
Multifunction LCD Display
New Batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: CyberPower
Model: CyberPower Smart App LCD UPS 2200VA 1320W, RM, 2U, 20A, 120V
Condition: New Batteries, Refurbished UPS
Part Number: OR2200LCDRT2U
Maximum Output: 1320W / 2000VA
Typical Backup Time at Half Load: 13 Minutes (660 Watts)
Typical Backup Time at Full Load: 5 Minutes (1320 Watts)
Input: NEMA 5-20P, 120V / 20A
Output: (8) NEMA 5-20R Battery & Surge Protected Outlets
Topology: Line-Interactive
Output Waveform: Simulated Sine Wave on Battery
Automatic Voltage Regulation (AVR): Yes
Local Management: USB, Serial & Dry Contact
Display: Multifunction LCD
Warranty: 1 Year Full Replacement Warranty
Â
Â
Â
CyberPower Smart App LCD UPS 2000VA 1320W RM 2U OR2200LCDRT2U - User's Manual
Â
Â
Â
OR2200LCDRT2U - CyberPower Smart App LCD UPS 2200VA Specifications:
| General: | Â | Â |
| UPS Topology | Line Interactive | Â |
| Energy Saving | GreenPower UPSâ„¢ Bypass | Â |
| ENERGY STAR® Qualified | Yes |  |
| Â | Â | Â |
| Main | Â | Â |
| Manufacturer | CyberPower | Â |
| Product Series | Smart App LCD | Â |
| Part Number | OR2200LCDRT2U | Â |
| Power Capacity | 2000VA / 1320W | Â |
| UPS Topology | Line-Interactive | Â |
| Nominal Voltage | 120V AC | Â |
| Output Waveform | Simulated Sine Wave on Battery | Â |
| Energy-Saving Technology | GreenPower UPS Bypass Technology | Â |
| Primary Form Factor | Rack / Tower | Â |
| Rack Height | 2U | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V AC | Â |
| Input Voltage Range | Automatic Voltage Regulation supports correction of abnormal utility voltage | Â |
| Input Frequency | 50/60 Hz ±3 Hz, auto-sensing |  |
| Input Plug | NEMA 5-20P | |
| Input Circuit Breaker | 20A | Â |
| Recommended Branch Circuit Protection | 20A maximum | Â |
| Input Phase | Single-Phase | Â |
| Input Cord Length | 10 ft (3.0 m) | Â |
| Plug Style | Right Angle | Â |
| Â | Â | Â |
| Output | Â | Â |
| Output Capacity | 2000VA | Â |
| Output Watt Capacity | 1320W | Â |
| Nominal Output Voltage | 120V AC | Â |
| On-Battery Output Voltage | 120V AC ±10% |  |
| On-Battery Frequency | 50/60 Hz ±1% |  |
| On-Battery Waveform | Simulated Sine Wave | Â |
| Total Output Receptacles | 8 | Â |
| Output Connections | (8) NEMA 5-20R | |
| Battery & Surge Protected Outlets | 8 | Â |
| Overload Protection | Internal circuitry limiting and resettable circuit breaker | Â |
| Typical Transfer Time | 10 ms | Â |
| Â | Â | Â |
| Voltage Regulation | Â | Â |
| Automatic Voltage Regulation | Yes | Â |
| AVR Function | Corrects abnormal utility voltage without using battery power | Â |
| Low-Voltage Correction | Automatic boost | Â |
| Regulated Output | Maintains safe 110V / 120V output during AVR operation | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Sealed Maintenance-Free Lead-Acid | Â |
| Battery Configuration | (4) 12V / 9Ah batteries | Â |
| Typical Runtime at Half Load | 13 minutes (660W) | Â |
| Typical Runtime at Full Load | 5 minutes (1320W) | Â |
| Replacement Battery Cartridge | RB1290X4L | Â |
| Replacement Battery Cartridge Quantity | 1 | Â |
| User-Replaceable Battery | Yes | Â |
| Battery Access | Front-accessible battery compartment | Â |
| Typical Recharge Time | 8 hours from total discharge | Â |
| Typical Battery Life | 3–6 years, depending on discharge/recharge cycles |  |
| Extended Runtime | No | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Local Management | Yes | Â |
| Network Management | Optional | Â |
| Network Management Slot | SNMP/HTTP Network Slot | Â |
| Optional Network Card | Compatible optional CyberPower RMCARD | Â |
| Network Monitoring | Remote UPS monitoring and management supported with compatible optional RMCARD | Â |
| USB Interface | Yes | Â |
| Primary Serial Port | Yes | Â |
| Dry Contact Interface | Yes | Â |
| Primary Serial Function | UPS-to-computer monitoring and communication | Â |
| Dry Contact Function | Provides basic UPS status information to compatible equipment | Â |
| Multi-System Shutdown | USB and Primary Serial interfaces support simultaneous shutdown of two computer systems | Â |
| Management Software | PowerPanel Business Edition | Â |
| Software Functions | UPS monitoring, configuration and automatic computer shutdown during utility power loss | Â |
| Communication Protection | RJ11/RJ45 modem, fax, telephone and network/Ethernet protection | Â |
| Management Cables | USB cable, DB9 serial cable and telephone cable | Â |
| Â | Â | Â |
| User Interface, Alerts & Controls | Â | Â |
| Display | High-Resolution Multifunction LCD | Â |
| LCD Monitoring | Displays input voltage, output voltage, estimated runtime, battery capacity and output load | Â |
| LCD Status | Displays Normal, Battery, AVR, Silent Mode, Overload and Fault conditions | Â |
| Battery Capacity Meter | Displays approximate battery charge in 20% increments | Â |
| Load Capacity Meter | Displays approximate output load in 20% increments | Â |
| Power Indicator | LED Power On indicator | Â |
| Wiring Fault Indicator | Dedicated red site-wiring fault LED | Â |
| Audible Alarms | Battery operation, low battery, overload and fault conditions | Â |
| Silent Mode | Yes | Â |
| LCD Function Control | Front-panel function selection switch | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| Surge Suppression | 1840 J | Â |
| EMI/RFI Filtration | Yes | Â |
| RJ11/RJ45 Protection | 1-In / 1-Out | Â |
| Coaxial RG6 Protection | 1-In / 1-Out | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Form Factor | Rack / Tower | Â |
| Rack Height | 2U | Â |
| Construction | Metal | Â |
| Dimensions (W × H × D) | 17.2 × 3.5 × 15.7 in |  |
| Net Weight | 52.7 lb (23.9 kg) | Â |
| Rack Mount Brackets | Supported / included | Â |
| Tower Stands | Supported / Not included | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Operating Relative Humidity | 0–90%, non-condensing |  |
| Â | Â | Â |
| Conformance | Â | Â |
| Safety Approvals | UL 1778 / CSA C22.2 No. 107 | Â |
| FCC Compliance | FCC DOC Class B | Â |
| Canadian Compliance | CAN ICES-3 (B) / NMB-3(B) | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |