CyberPower Smart App Sinewave UPS 1500VA 1350W RM 2U 120V - 15A
Model: PR1500LCDRT2U
Input: NEMA 5-15P (120V - 15A)
Output: (8) NEMA 5-15R Battery Backup & Surge Protected
Line-Interactive UPS - Pure Sine Wave Output
Automatic Voltage Regulation (AVR)
USB, Serial, Dry Contact & EPO Interfaces
Multifunction LCD Status & Control Display
New Batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: CyberPower
Model: CyberPower Smart App Sinewave UPS 1500VA 1350W, 15A, 120V, RM, 2U
Condition: New Batteries, Refurbished UPS
Part Number: PR1500LCDRT2U
Maximum Output: 1350W / 1500VA
Typical Backup Time at Half Load: 11 Minutes (675 Watts)
Typical Backup Time at Full Load: 4 Minutes (1350 Watts)
Input: NEMA 5-15P, 120V / 15A
Output: (8) NEMA 5-15R Battery Backup & Surge Protected
Topology: Line-Interactive
Output Waveform: Pure Sine Wave
Automatic Voltage Regulation: Yes (AVR)
Network Management: Optional SNMP/HTTP Network Management Card
Management Slot: SNMP/HTTP Network Slot
Communications: USB, Serial & Dry Contact
Software: PowerPanel Business
Display: Multifunction LCD Status & Control Display
Emergency Power Off: Yes
Warranty: 1 Year Full Replacement Warranty
Â
Â
CyberPower Smart App Sinewave UPS 1500VA 1350W RM 2U PR1500LCDRT2U - User's Manual
Â
Â
Â
PR1500LCDRT2U - CyberPower Smart App Sinewave UPS 1500VA Specifications:
| Main | Â | ||
| Manufacturer | CyberPower | ||
| Product Series | Smart App Sinewave | ||
| Model | PR1500LCDRT2U | ||
| UPS Topology | Line-Interactive | ||
| Power Capacity | 1500VA / 1350W | ||
| Power Factor | 0.9 | ||
| Nominal Input Voltage | 120V AC | ||
| Nominal Output Voltage | 120V AC | ||
| Output Waveform | Pure Sine Wave on Battery | ||
| Form Factor | Rackmount | ||
| Rack Height | 2U | ||
| Energy-Saving Technology | GreenPower UPS | ||
| Automatic Voltage Regulation | Yes | ||
| Condition | New Batteries, Refurbished UPS | ||
| Warranty | 1 Year Full Replacement Warranty | ||
| Â | Â | ||
| Input | Â | ||
| Nominal Input Voltage | 120V AC | ||
| Input Voltage Range | 80–150V AC | ||
| Input Frequency | 50/60 Hz Auto-Sensing | ||
| Input Frequency Range | 47–63 Hz | ||
|
Plug Type |
|
||
| Plug Style | Right Angle, 45° Offset Right | ||
| Electrical Service | 15A / 120V | ||
| Input Cord Length | 10 ft | ||
| Input Phase | Single-Phase | ||
| Input Protection | Circuit Breaker | ||
| Â | Â | ||
| Output | Â | ||
| Output Capacity | 1500VA / 1350W | ||
| Output Power Factor | 0.9 | ||
| Nominal Output Voltage | 120V AC | ||
| Battery Mode Output Voltage | 120V AC ±5% | ||
| Battery Mode Frequency | 50/60 Hz ±0.1 Hz | ||
| Battery Mode Waveform | Pure Sine Wave | ||
| Total Outlets | 8 | ||
|
Outlet Type |
|
||
| Battery Backup & Surge Protected Outlets | 8 | ||
| Critical Load Outlets | 4 | ||
| Non-Critical / Programmable Outlets | 4 | ||
| Surge-Only Outlets | 0 | ||
| Transfer Time | 4 ms Typical | ||
| Overload Protection - Utility | Circuit Breaker | ||
| Overload Protection - Battery | Internal Current Limiting | ||
| Load Prioritization | Supported through Critical / Non-Critical outlet groups | ||
| Programmable Outlet Control | Supported through PowerPanel Business | ||
| Â | Â | ||
| Voltage Regulation | Â | ||
| Automatic Voltage Regulation (AVR) | Yes | ||
| AVR Input Operating Range | 80–150V AC | ||
| Boost 1 | +30% | ||
| Boost 2 | +14% | ||
| Buck | -12% | ||
| AVR Operation | Corrects high/low utility voltage without switching to battery | ||
| Â | Â | ||
| Batteries & Runtime | Â | ||
| Battery Type | Sealed Lead-Acid | ||
| Internal Battery Configuration | (4) 12V / 7Ah batteries | ||
| DC System Voltage | 48V DC | ||
| Typical Runtime at Half Load | 11 Minutes (675W) | ||
| Typical Runtime at Full Load | 4 Minutes (1350W) | ||
| Hot-Swappable Batteries | Yes | ||
| User-Replaceable Batteries | Yes | ||
| Internal Battery Pack | RBP832 | ||
| Battery Access | Front | ||
| Recharge Time | Approximately 4–8 hours recommended after battery replacement / initial charging | ||
| Extended Runtime | No external battery expansion specified for PR1500LCDRT2U | ||
| Automatic Charging | Yes | ||
| Automatic Restart | Yes | ||
| Â | Â | ||
| Communications & Management | Â | ||
| Local Management | Yes | ||
| Network Management | Optional | ||
| Compatible Network Management Card | CyberPower RMCARD205 | ||
| Network Management Slot | SNMP/HTTP Network Slot | ||
| SNMP / HTTP Remote Monitoring | Yes, with optional RMCARD205 | ||
| Remote Management | Web Browser, CLI, SNMP and Network Management System (NMS) with RMCARD205 | ||
| Remote UPS Monitoring | Supported with optional RMCARD205 | ||
| Remote UPS Control | Monitoring, configuration, scheduled shutdown, startup and reboot with RMCARD205 | ||
| Supported Network Protocols with RMCARD205 | TCP/IP, UDP, FTP, SCP, DHCP, DNS, SSH, Telnet, HTTP/HTTPS, SNMPv1/v3, IPv4/IPv6, NTP, SMTP and Syslog | ||
| Event Notifications | Email, SMS, SNMP Traps and Syslog with RMCARD205 | ||
| Environmental Monitoring | Supported with RMCARD205 and compatible optional environmental sensor | ||
| Ethernet | 10/100 Mbps via RMCARD205 | ||
| USB Interface | Yes | ||
| Primary Serial Port | Yes | ||
| Secondary Serial / Dry Contact Interface | Yes | ||
| USB / Serial Simultaneous Operation | No; USB and primary serial cannot be used simultaneously | ||
| Dry Contact Support | Yes | ||
| Emergency Power Off (EPO) | Yes | ||
| Management Software | PowerPanel Business | ||
| PowerPanel Monitoring | UPS status, battery status, scheduling, testing and programmable parameters | ||
| Protected Communications | RJ11/RJ45, 1-In / 1-Out | ||
| Coaxial Surge Protection | 1-In / 1-Out | ||
| Â | Â | ||
| User Interface, Alerts & Controls | Â | ||
| Display | Multifunction LCD | ||
| Input Voltage Display | Yes | ||
| Output Voltage Display | Yes | ||
| Output Frequency Display | Yes | ||
| Estimated Runtime Display | Yes | ||
| Load Capacity Display | Yes | ||
| Battery Capacity Display | Yes | ||
| Temperature Display | Celsius / Fahrenheit | ||
| AVR Status | Displayed | ||
| Battery Mode Status | Displayed | ||
| Silent Mode | Supported | ||
| Overload Status | Displayed | ||
| Fault Status | Displayed | ||
| LED Indicators | Power On, Wiring Fault | ||
| Audible Alarms | On Battery, Low Battery, Overload / Fault Conditions | ||
| Manual Self-Test | Yes | ||
| User-Configurable Delay Time | Yes | ||
| Static Frequency Tolerance | Configurable | ||
| Slew Rate | Configurable | ||
| Low-Battery Shutdown Voltage | Configurable | ||
| Â | Â | ||
| Power Management Features | Â | ||
| Critical Outlet Group | (4) NEMA 5-15R | ||
| Non-Critical Outlet Group | (4) NEMA 5-15R | ||
| Load Shedding | Supported | ||
| Runtime Prioritization | Supported | ||
| Programmable Non-Critical Outlets | Yes | ||
| Scheduled UPS Operation | Supported through PowerPanel Business | ||
| Automatic Computer Shutdown | Supported | ||
| Auto-Charger | Yes | ||
| Auto-Restart | Yes | ||
| Â | Â | ||
| Surge Protection & Filtering | Â | ||
| AC Surge Protection | Yes | ||
| Surge Suppression | 1874 Joules | ||
| EMI/RFI Filtering | Yes | ||
| RJ11/RJ45 Protection | 1-In / 1-Out | ||
| Coax / Cable / DSS Protection | Yes | ||
| Â | Â | ||
| Physical | Â | ||
| Form Factor | Rackmount | ||
| Rack Height | 2U | ||
| Dimensions | Approximately 17.1 × 3.5 × 15.3 in | ||
| Weight | Approximately 60 lb | ||
| Cooling | Fan-Cooled | ||
| Rack Installation | Rackmount | ||
| Battery Access | Front Panel | ||
| Â | Â | ||
| Environmental | Â | ||
| Operating Temperature | 32–104°F (0–40°C) | ||
| Operating Relative Humidity | 0–95%, Non-Condensing | ||
| Â | Â | ||
| Conformance | Â | ||
| Safety Approvals | UL1778, cUL107 | ||
| FCC | FCC / DoC Class B | ||
| Â | Â | ||
| Condition & Warranty | Â | ||
| Battery Condition | New Batteries | ||
| UPS Condition | Refurbished UPS | ||
| Warranty | 1 Year Full Replacement Warranty |