Eaton 5PX G2 UPS 1950VA 1950W RM 2U 120V 20A 5PX2000RTG2 - Refurbished

Eaton 5PX G2 1950VA 1950W RM 2U 120V 20A
Model: 5PX2000RTG2
Input: NEMA 5-20P
Output: (1) NEMA L5-20R, (6) NEMA 5-20R
Line Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Back Order

Manufacturer: Eaton
Model: Eaton 5PX 2000VA 1950W RM 2U 120V
Condition: New batteries, refurbished UPS
Part Number: 5PX2000RTG2
Maximum output: 1950VA / 1950W
Warranty: 1-Year full replacement warranty with registration

 


Eaton 5PX2000RTG2 - UPS 1950VA 1950W RM 2U 120V - User's Manual

 

 


5PX2000RTG2 - Eaton 5PX 2000VA 1950W Specifications:

 

Main:

Main Input Voltage

120V

Main Output Voltage

120V

Kw Rating

1950W

Rated Power in VA

1950VA

Input Connection Type

NEMA 5-20P

Output Connection Type

(1) L5-20R, (6) 5-20R

Number of Rack Units

2U

Cable Length

10 ft (3.05 m)

Number of Cables

1

Battery Type

Sealed, lead-acid

 

Batteries & Runtime:

Included Battery Modules

0

Extendable Run Time

Up to 4 external battery modules (EBM) available for extended runtimes

Battery Slots Empty

4 (for external battery modules)

Typical Recharge Time

3 hours

RBC Quantity

1 (User Replaceable)

Battery Life

3-5 years (with proper maintenance)

Replacement Battery

EBP-1616

Battery Charge Power (Watts)

540W rated

 

General:

Number of Power Module Filled Slots

0

Number of Power Module Free Slots

0

Redundant

 

No

 

Physical:

Color

Black

Height

3.4 in (8.64 cm)

Width

17.2 in (43.69 cm)

Depth

23.7 in (60.2 cm)

Net Weight

65.3 lb (29.6 kg)

Mounting Location

Front

Mounting Preference

Lower

Mounting Mode

Rackmount / Tower Convertible

Two Post Mountable

Yes (Included 4-post rail kit)

USB Compatible

Yes (USB and RS-232 ports included)

Input:

Efficiency at Full Load

Up to 98% at maximum load

Input Frequency

50/60 Hz (auto-sensing)

Input Voltage Range

89–151 VAC (adjustable to 70–153 VAC)

Input Power Factor

1.0 (optimal power utilization)

 

Output:

Harmonic Distortion

Less than 5% at full load

Maximum Configurable Power in VA

1950 VA

Max Configurable Power (Watts)

1950W

Transfer Time

2ms typical; 4ms maximum

Topology

Line-Interactive

Waveform Type

Pure Sine Wave

Output Frequency (sync to mains)

47...53 Hz for 50 Hz nominal; 57...63 Hz for 60 Hz nominal sync to mains

 

Environmental:

Acoustic Level

<45 dBA at 1 meter

Heat Dissipation

Online: 154 BTU/hr, Battery: 744 BTU/hr

Operating Altitude

Up to 10,000 ft (3000 m) without derating

Ambient Air Temperature for Operation

0°C to 40°C (32°F to 104°F)

Ambient Air Temperature for Storage

-5°C to 55°C (23°F to 131°F)

Storage Altitude

Up to 50,000 ft (15,240 m)

Relative Humidity

0–90% (non-condensing)

Storage Relative Humidity

0–95% (non-condensing)

 

Communications & Management:

Control Panel

LCD graphical display, load and battery status indicators

Emergency Power Off (EPO)

Optional (can be integrated)

SmartSlotâ„¢ Cards

Gigabit Network Management Card (Optional) 

Alarm

Battery low, overload, replace battery, and other notifications

 

Surge Protection & Filtering:

Surge Energy Rating

480 Joules

Filtering

Full-time multi-pole noise filtering, IEEE surge let-through, zero clamping time

 