Eaton EMI102-10 Metered PDU 0U, 120V, 2880W, 24A Output: (30) 5‑20R – Refurbished

Eaton Metered Input PDU 0U, 120V, 24A, 2880W
Model: EMI102-10
Input Connection: NEMA L5-30P (120V)
Cord Length: 10 ft
Output Connections: (30) NEMA 5-20R
Phase: Single-Phase
Condition: Refurbished PDU
Warranty: 1-Year Replacement Warranty

 

In stock

Manufacturer: Eaton

Model: EMI102-10
Input Connection: NEMA L5-30P, 10 ft cord
Output Connections: (30) NEMA 5‑20R
Phase: Single-Phase
Maximum Power: 2.88 kW
Current Rating: 24 A
Frequency: 50–60 Hz
Condition: Refurbished PDU
Warranty: 1-Year Replacement Warranty

Product Description:
The Eaton EMI102-10 is a 0U vertical, single-phase metered input PDU designed for space-saving rack deployment. It provides real-time load monitoring and features 30 NEMA 5‑20R outlets to power servers, networking, and IT equipment. This PDU includes an L5-30P input and a 10-foot power cord, supporting a maximum of 2.88 kW at 120 V. It is ideal for data centers and rack environments where precise monitoring of connected loads is required.

 


Eaton EMI102-10 Metered PDU 0U, 120V - User Manual

 

 

Eaton EMI102-10 Specifications:

Input

Nominal Input Voltage

120V

Input Frequency

50–60 Hz

Input Connection

NEMA L5-30P

Cord Length

10 ft (3.05 m)

Acceptable Input Voltage

120V ±10%

Maximum Input Current

24A

Number of Power Cords

1

Overload Protection

Yes

Phase

Single-Phase

 

Output

Output Connector(s)

(30) NEMA 5-20R

Maximum Total Current Draw

24A

Output Power (Max)

2.88 kW

Remote Outlet Monitoring

Yes (Metered PDU)

Outlet Control

No (Not switched)

Typical Transfer Time

N/A

Power Distribution Type

Metered Vertical Rack PDU

 

Environmental

Operating Temperature

0°C to 60°C (32°F to 140°F)

Operating Relative Humidity

5–95% non-condensing

Operating Elevation

0–3,000 m

Storage Temperature

-25°C to 65°C (-13°F to 149°F)

Storage Relative Humidity

5–95% non-condensing

Storage Elevation

0–15,000 m

 

User Interface, Alerts & Controls

Local Display

Advanced LCD pixel display

Display Functions

Displays current, voltage, power, energy usage, and configuration settings

Configuration Options

Local setup for IP address, display rotation, and network parameters

Status Indicators

Real-time load monitoring and alarm/status notifications

Alarm Functions

Overload and threshold alarm notifications

Hot-Swap Meter

Hot-swappable monitoring module for servicing without powering down connected equipment

 

Communications & Management

Ethernet Interface

Yes — RJ-45 network connectivity

Serial Interface

RS-232

Remote Monitoring

Yes — network-based monitoring of input load and power usage

Management Protocols

SNMP, Web interface

Daisy Chain Support

Supports IP daisy chaining for up to 4 PDUs on a single network connection

Monitoring Capabilities

Input current, voltage, power, energy consumption, and branch circuit monitoring

Accuracy ±1% billing-grade power monitoring accuracy
Network Configuration Configurable through LCD interface or web management
Outlet Control No — metered input only, not switched
Environmental Monitoring Optional EMP environmental monitoring support
Firmware/Management Support Compatible with Eaton ePDU G3 management platform

 

Physical

Mounting Location

Side or Vertical Rack

Form Factor

0U Vertical Rackmount

Material

Steel

Height

66.5 in (169 cm)

Width

2.05 in (52 mm)

Depth

2.05 in (52 mm)

Unit Weight

14.77 lbs (6.7 kg)

Shipping Weight

18 lbs (8.2 kg)

 

Certifications & Compliance

Compliance

RoHS Compliant, TAA Compliant

Certifications