Eaton ePDU G3 Metered Input 5.76kW 24A 120/240V 0U
Model: EMI200-10
Input: NEMA L14-30P (120/240V - 30A), 10 ft Cord
Output: (8) NEMA 5-20R, (20) IEC C13, (6) IEC C19, Outlet-Grip Technology
Maximum Power Capacity: 5.76kW / 5760W
Split-Phase Power Distribution
Metered Input PDU with Remote Power Monitoring
(2) 20A Circuit Breakers
Refurbished PDU
1 Year Replacement Warranty Included
In stock
Manufacturer: Eaton
Model: Eaton ePDU G3 Metered Input 5.76kW 24A 120/240V 0U
Part Number: EMI200-10
Condition: Refurbished PDU
Maximum Power Capacity: 5.76kW / 5760W
Input: NEMA L14-30P, 120/240V, 30A Plug, 10 ft Power Cord
Rated Current: 24A
Output: (8) NEMA 5-20R, (20) IEC C13, (6) IEC C19
Total Output Receptacles: 34
Power Configuration: Split-Phase
PDU Type: Metered Input
Network Management: Integrated Ethernet and RS-232 Communications
Circuit Protection: (2) 20A Circuit Breakers
Form Factor: Vertical Rackmount 0U
Warranty: 1 Year Replacement Warranty
Â
Â
Â
Â
Eaton EMI200-10 ePDU G3 Metered Input 0U 24A 120/240V - User Manual
Â
Â
Â
Â
EMI200-10 -Â Eaton ePDU G3 Metered Specifications:Â
| Main | Â | Â |
| Manufacturer | Eaton | Â |
| Model | EMI200-10 | Â |
| Product Family | Eaton ePDU G3 | Â |
| Product Type | Rack Power Distribution Unit (PDU) | Â |
| PDU Technology | Metered Input | Â |
| Maximum Power Capacity | 5.76kW / 5760W | Â |
| Rated Current | 24A | Â |
| Main Input Voltage | 120/240V AC | Â |
| Power Configuration | Split-Phase | Â |
| Input Plug | NEMA L14-30P | Â |
| Total Output Receptacles | 34 | Â |
| Form Factor | Vertical Rackmount 0U | Â |
| Outlet Switching | No | Â |
| Condition | Refurbished PDU | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120/240V AC | Â |
| Input Connection Type | NEMA L14-30P | |
| Input Plug Rating | 30A | Â |
| Rated Operating Current | 24A | Â |
| Input Phase | Split-Phase | Â |
| Input Frequency | 50/60Hz | Â |
| Power Cord Length | 10 ft (3.05 m) | Â |
| Number of Input Cords | 1 | Â |
| Maximum Rated Power | 5760W | Â |
| Â | Â | Â |
| Output | Â | Â |
| Total Output Receptacles | 34 | Â |
| NEMA 5-20R Outlets | 8 | |
| IEC C13 Outlets | 20 | |
| IEC C19 Outlets | 6 | |
| Output Configuration | (8) NEMA 5-20R, (20) IEC C13, (6) IEC C19 | Â |
| IEC Outlet-Grip Technology | Yes, C13 and C19 | Â |
| Individual Outlet Switching | No | Â |
| Individual Outlet Control | No | Â |
| Output Power Distribution | Split-Phase | Â |
| Maximum Total Power | 5.76kW | Â |
| Â | Â | Â |
| Circuit Protection | Â | Â |
| Circuit Breakers | (2) 20A | Â |
| Branch Circuit Protection | Yes | Â |
| Overcurrent Protection | Integrated Circuit Breakers | Â |
| Â | Â | Â |
| Metering & Monitoring | Â | Â |
| PDU Monitoring Type | Metered Input | Â |
| Input Power Monitoring | Supported | Â |
| Network Monitoring | Supported | Â |
| Ethernet Interface | Yes | Â |
| Serial Interface | RS-232 | Â |
| Local Metering | Supported | Â |
| Individual Outlet Switching | Not Supported | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Network Communication | Integrated Ethernet Interface | Â |
| Ethernet Port | Yes | Â |
| Serial Communication | RS-232 | Â |
| Remote Power Monitoring | Supported | Â |
| Network Management | Supported Through Integrated Management Interface | Â |
| Eaton ePDU G3 Management | Supported | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Mounting Type | Vertical Rackmount | Â |
| Rack Space | 0U | Â |
| Mounting Orientation | Vertical | Â |
| Length | 66.5 in (1689.1 mm) | Â |
| Width | 2.05 in (52.1 mm) | Â |
| Depth | Approximately 2.0–2.1 in (50.8–53.3 mm) |  |
| Color | Black | Â |
| Power Cord Length | 10 ft | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |  |
| Input Frequency | 50/60Hz | Â |
| Â | Â | Â |
| Certifications & Compliance | Â | Â |
| Safety Certification | UL Listed | Â |
| TAA Compliance | Listed as TAA Compliant | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| PDU Condition | Refurbished | Â |
| Batteries Required | No | Â |
| Warranty | 1 Year Replacement Warranty | Â |