Eaton Powerware 9130 1000VA 900W RM 2U 120V
Model: PW9130L1000R-XL2U
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Double Conversion - Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Eaton
Model:Â Eaton Powerware 9130 1000VA 900W, RM 2U, 120V
Condition: New batteries, refurbished UPS
Part Number: PW9130L1000R-XL2U
Maximum output: 900WÂ /Â 1000VA
Typical backup time at half load: 24Â minutes (450 Watts)
Typical backup time at full load: 10 minutes (900 Watts)
Warranty: 1 year full replacement warranty
Included: PW9130L1000R-XL2U UPS. No accessories included.
Eaton 9130 1000VA 900W PW9130L1000R-XL2U Manual
PW9130L1000R-XL2U - Eaton Powerware Specifications:
General:
|
Topology |
Online (Double Conversion) |
|
Configuration |
Rackmount |
|
Color |
Black |
|
Rating (VA/Watts) |
1000/900 |
|
Diagnostics |
Full system self-test |
|
Efficiency |
>95% in high-efficiency mode; >86% in online mode |
|
UPS Bypass |
Automatic bypass |
|
Rail Kit |
Not included |
|
Remote Emergency Power off (REPO) |
Emergency shutdown control through the REPO port |
|
Dimensions (H x W x D, inches) |
3.4 x 17.2 x 17.7 |
|
Weight (lbs) |
35.3 |
Input:
|
Connection |
|
||
|
Input Cord |
6 ft. (1.8 m) |
||
|
Input Voltage Range |
90-138 Vac |
||
|
Nominal Voltage |
120V |
||
|
Frequency |
50/60 Hz |
||
|
Frequency Range |
45–65 Hz |
||
|
Nominal Current |
5.8 A |
||
|
Breaker Ratings |
15A |
||
|
Generator Compatability |
Yes |
Output:
|
Output Receptacles |
|
||
|
On Utility Voltage Regulation |
±3% of nominal |
||
|
On Battery Voltage Regulation |
±3% of nominal |
||
|
Voltage Wave Shape (On Battery) |
Sine wave |
||
|
Power Factor |
0.9 |
||
|
Frequency Regulation |
±3% Hz online |
||
|
Load Crest Factor |
3 to 1 |
Battery:
|
Maximum Number of Battery Packs |
4 |
|
Battery Type |
36 Vdc; (3) 12V, 9 Ah |
|
Half Load Runtime (in mins) |
24 |
|
Full Load Runtime (in mins) |
10 |
|
Battery Replacement |
Hot-swappable internal and external batteries |
|
Start On Battery |
Allows start of UPS without utility input |
|
Recharge Time |
Internal batteries: 3 hours. 1 EBM: 9 hours; 2 EBM: 15 hours; 3 EBM: 21 hours; 4 EBM: 27 hours |
Communications:
|
User Interface |
Graphical LCD with blue backlight and text in English, French, German, Russian and Spanish |
|
LEDs |
Four status-indicating LEDs |
|
Communication Ports |
(1) USB, (1) RS-232 serial, Relay output (common alarm standard) |
|
Communications Slot |
Optional communication slots (BD Slot) |
|
Optional Communication Cards (not included) |
SNMP/Web card for direct control and monitoring in SNMP-based networks, monitoring of UPS status and meters through Web browser interface Relay card for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems |
Environmental & Standards:
|
RoHS Compliance |
Yes |
|
Heat Dissipation (BTU) |
Line: 500, Bat: 674 |
|
Audible Noise |
<50 dB |
|
Operating Temperature |
-20ËšC (-4ËšF) to +40ËšC (104ËšF) with batteries |
|
Safety markings |
UL, cUL, VCCI |
|
EMC Markings |
FCC Class B, EN55022 Class B |
|
Storage Temperature |
-20°C (-4°F) to +40°C (104°F) with batteries and -25°C (-13°F) to +55°C (131 °F) without batteries |
|
Relative Humidity |
5–90% non-condensing |