Eaton Powerware 9130 3000VA 2700W Rackmount 2U 120V 30A
Model: PW9130L3000R-XL2UN
Input: NEMA L5-30P (120V - 30A)
Output: (6) NEMA 5-20R, (1) NEMA L5-30R
True Online Double-Conversion UPS - Sine Wave Output
Extended Runtime Capability - Supports up to (4) EBMs
Eaton NETWORK-M2 Network Management Card Preinstalled
Web/SNMP Remote Monitoring & Management
New Batteries, Refurbished UPS
1 Year Full Replacement Warranty Included
In stock
Manufacturer: Eaton Powerware
Model: Eaton Powerware 9130 3000VA 2700W RM 2U 120V 30A
Condition: New Batteries, Refurbished UPS
Part Number: PW9130L3000R-XL2UN
Maximum Output: 2700W / 3000VA
Typical Backup Time at Half Load: 13 Minutes (1350 Watts)
Typical Backup Time at Full Load: 5 Minutes (2700 Watts)
Input: NEMA L5-30P, 120V / 30A
Output: (6) NEMA 5-20R, (1) NEMA L5-30R
Topology: True Online Double-Conversion
Output Waveform: Sine Wave
Extended Runtime: Supports up to (4) External Battery Modules (EBMs)
Network Management: Eaton NETWORK-M2 Network Management Card Preinstalled
Remote Management: Web / SNMP Remote Monitoring & Management
Warranty: 1 Year Full Replacement Warranty
Description: The Eaton Powerware 9130 PW9130L3000R-XL2UN is a 3000VA / 2700W True Online Double-Conversion UPS designed for servers, networking equipment, and other critical systems. It features an Eaton NETWORK-M2 Network Management Card preinstalled for Web/SNMP remote monitoring and management, supports up to (4) External Battery Modules for extended runtime, and comes refurbished with new batteries and a 1 Year Full Replacement Warranty.
Â
Â
Eaton Powerware 9130 3000VA 2700W PW9130L3000R-XL2UN - User Manual
Â
Â
PW9130L3000R-XL2UN - Eaton Powerware 9130 3000VA Specifications:
| Main | Â | ||||
| Manufacturer | Eaton Powerware | ||||
| Product Series | Eaton 9130 | ||||
| Model | PW9130L3000R-XL2UN | ||||
| Product Type | Uninterruptible Power Supply (UPS) | ||||
| Power Capacity | 3000VA / 2700W | ||||
| Output Power Factor | 0.9 | ||||
| UPS Topology | True Online Double-Conversion | ||||
| Configuration | Rackmount | ||||
| Rack Height | 2U | ||||
| Nominal Voltage | 120V | ||||
| High-Efficiency Mode | Selectable | ||||
| Generator Compatibility | Yes | ||||
| Automatic Bypass | Yes | ||||
| Cold Start / Start on Battery | Supported | ||||
| Full System Self-Test | Supported | ||||
| Firmware Upgradeable | Yes | ||||
| Color | Black | ||||
| Condition | New Batteries, Refurbished UPS | ||||
| Warranty | 1 Year Full Replacement Warranty Included | ||||
| Â | Â | ||||
| Input | Â | ||||
| Nominal Input Voltage | 120V | ||||
| Selectable Input Voltage | 100 / 110 / 120 / 127V | ||||
|
Input Connection |
|
||||
| Input Cord Length | 6 ft | ||||
| Nominal Input Current | 25A | ||||
| Input Breaker Rating | 30A | ||||
| Input Voltage Range | 90–144 VAC | ||||
| Input Frequency | 50/60 Hz | ||||
| Input Frequency Range | 45–65 Hz | ||||
| Input Phase | Single-Phase | ||||
| Â | Â | ||||
| Output | Â | ||||
| Rated Output Power | 2700W | ||||
| Rated Output Capacity | 3000VA | ||||
| Nominal Output Voltage | 120V | ||||
| Selectable Output Voltage | 100 / 110 / 120 / 127V | ||||
| Total Output Receptacles | 7 | ||||
|
Output Receptacles |
|
||||
| Output Waveform | Sine Wave | ||||
| Output Power Factor | 0.9 | ||||
| On-Utility Voltage Regulation | ±3% of Nominal | ||||
| On-Battery Voltage Regulation | ±3% of Nominal | ||||
| Frequency Regulation | ±3 Hz Online | ||||
| Load Crest Factor | 3:1 | ||||
| Output Breakers | (2) 20A AC Breakers | ||||
| Internal Bypass | Automatic | ||||
| Output Configuration | Load Segment Capability Supported | ||||
| Â | Â | ||||
| Batteries & Runtime | Â | ||||
| Battery Type | Sealed Lead-Acid | ||||
| Internal Battery Voltage | 72 VDC | ||||
| Internal Battery Configuration | (6) 12V Batteries | ||||
| Battery Capacity | 9Ah | ||||
| Battery Management | Eaton ABM Technology | ||||
| Hot-Swappable Batteries | Yes | ||||
| User-Replaceable Batteries | Yes | ||||
| Start on Battery | Yes | ||||
| Internal Battery Recharge Time | Approx. 3 Hours to 90% | ||||
| Extended Runtime | Yes | ||||
| Compatible External Battery Module | PW9130N3000R-EBM2U | ||||
| EBM Voltage | 72 VDC | ||||
| Maximum External Battery Modules | Up to (4) | ||||
| EBM Connection | External Three-Pole Anderson Connector | ||||
| Recharge Time with 1 EBM | Approx. 9 Hours | ||||
| Recharge Time with 2 EBMs | Approx. 15 Hours | ||||
| Recharge Time with 3 EBMs | Approx. 21 Hours | ||||
| Recharge Time with 4 EBMs | Approx. 27 Hours | ||||
| Battery Test | Automatic Battery Testing Supported | ||||
| Typical Backup Time at Half Load | 13 Minutes (1350W) | ||||
| Typical Backup Time at Full Load | 5 Minutes (2700W) | ||||
| Â | Â | ||||
| Communications & Management | Â | ||||
| Network Management Card | Eaton NETWORK-M2 Preinstalled | ||||
| Network Card Status | Included / Preinstalled | ||||
| Network Card Model | NETWORK-M2 | ||||
| Network Management | Integrated through preinstalled NETWORK-M2 | ||||
| Communication Expansion Bay | (1), occupied by NETWORK-M2 | ||||
| NETWORK-M2 Ethernet | 10/100/1000 Mbps | ||||
| Ethernet Network Management | Yes | ||||
| Web-Based Management | Yes | ||||
| SNMP Monitoring | Yes | ||||
| SNMP Support | SNMP v1 / SNMP v3 | ||||
| Remote UPS Monitoring | Yes | ||||
| Remote UPS Management | Yes | ||||
| Network Protocols | HTTP, HTTPS, SNMP v1/v3, NTP, SMTP/SMTPS, DHCP, CLI, SSH, ARP | ||||
| IP Support | IPv4 / IPv6 | ||||
| Secure Web Management | HTTPS | ||||
| Secure Command-Line Management | SSH / CLI | ||||
| Email / SMTP Support | SMTP / SMTPS | ||||
| Network Time Protocol | NTP | ||||
| Automatic IP Configuration | DHCP | ||||
| Environmental Monitoring | Supported with compatible environmental sensor | ||||
| Local Communication Ports | (1) USB, (1) RS-232 Serial | ||||
| Relay Output | Yes – Contact Closure | ||||
| Compatible Communication Card | Eaton Relay Interface Card | ||||
| Programmable Signal Inputs | (4) | ||||
| Relay Output Contacts | (1) Three-Pole Connector with Contact Closure | ||||
| Remote Emergency Power Off | REPO Port | ||||
| Firmware Upgradeable | Yes | ||||
| Power Management Software | Eaton Power Management Software | ||||
| Â | Â | ||||
| User Interface, Alerts & Controls | Â | ||||
| User Interface | Graphical LCD with Blue Backlight | ||||
| Display Languages | English, French, German, Russian & Spanish | ||||
| Status Indicators | Four Status LEDs | ||||
| LCD Status Display | Yes | ||||
| UPS Status Monitoring | Yes | ||||
| Input Voltage Monitoring | Yes | ||||
| Output Voltage Monitoring | Yes | ||||
| Load Monitoring | Yes | ||||
| Battery Status Monitoring | Yes | ||||
| Event Log | Accessible from UPS Interface | ||||
| Operating Mode Selection | Supported | ||||
| High-Efficiency Mode Selection | Supported | ||||
| Bypass Configuration | Supported | ||||
| Load Segment Configuration | Supported | ||||
| Battery Settings | Configurable | ||||
| EBM Configuration | Supported | ||||
| Automatic Restart | Configurable | ||||
| Automatic Battery Test | Supported | ||||
| Alarm Management | Supported | ||||
| Â | Â | ||||
| Operating Modes | Â | ||||
| Normal Mode | Yes | ||||
| Online Double-Conversion Mode | Yes | ||||
| Battery Mode | Yes | ||||
| Bypass Mode | Yes | ||||
| Standby Mode | Yes | ||||
| High-Efficiency Mode | Yes | ||||
| Automatic Transfer to Bypass | Supported | ||||
| Manual Mode Transfer | Supported | ||||
| Â | Â | ||||
| Power Protection Features | Â | ||||
| Power Failure Protection | Yes | ||||
| Brownout Protection | Yes | ||||
| Voltage Sag Protection | Yes | ||||
| Surge Protection | Yes | ||||
| Line Noise Protection | Yes | ||||
| High Voltage Spike Protection | Yes | ||||
| Frequency Variation Protection | Yes | ||||
| Switching Transient Protection | Yes | ||||
| Harmonic Distortion Protection | Yes | ||||
| Utility Frequency Independence | Yes | ||||
| Generator Compatibility | Yes | ||||
| Â | Â | ||||
| Battery Management Features | Â | ||||
| Battery Management Technology | Eaton ABM | ||||
| Battery Recharge Optimization | Yes | ||||
| Battery Life Extension | Supported | ||||
| Battery End-of-Life Warning | Supported | ||||
| Automatic Battery Test | Supported | ||||
| External Battery Monitoring | Supported | ||||
| EBM Quantity Configuration | Supported | ||||
| Â | Â | ||||
| Physical | Â | ||||
| Form Factor | Rackmount | ||||
| Rack Height | 2U | ||||
| Rack Compatibility | Standard 19-inch Rack | ||||
| Height | 3.4 in | ||||
| Width | 17.2 in | ||||
| Depth | 23.6 in | ||||
| Net Weight | Approx. 65 lb | ||||
| Rack Ears | Horizontal | ||||
| Color | Black | ||||
| Â | Â | ||||
| Environmental | Â | ||||
| Operating Temperature | 32°F to 104°F (0°C to 40°C) | ||||
| Storage Temperature with Batteries | -4°F to 104°F (-20°C to 40°C) | ||||
| Storage Temperature without Batteries | -13°F to 131°F (-25°C to 55°C) | ||||
| Relative Humidity | 5–90%, Non-Condensing | ||||
| Audible Noise | Less than 50 dB | ||||
| Thermal Protection | Transfers Load to Bypass in Overtemperature Condition | ||||
| Â | Â | ||||
| Efficiency & Heat | Â | ||||
| Efficiency in High-Efficiency Mode | Greater than 95% | ||||
| Efficiency in Online Mode | Greater than 86% | ||||
| Heat Dissipation – Line Mode | 1257 BTU/hr | ||||
| Heat Dissipation – Battery Mode | 1755 BTU/hr | ||||
| Â | Â | ||||
| Certifications & Compliance | Â | ||||
| Safety Markings | UL, cUL, VCCI | ||||
| EMC Markings | FCC Class A, EN55022 Class A | ||||
| RoHS Compliance | Yes | ||||
| CE Compliance | Applicable CE-Marked Configurations | ||||
| EN Standards | EN 62040-1-1, EN 62040-2 | ||||
| Â | Â | ||||
| Condition & Warranty | Â | ||||
| Condition | New Batteries, Refurbished UPS | ||||
| Network Card Included | Eaton NETWORK-M2 Preinstalled | ||||
| Battery Condition | New Batteries | ||||
| UPS Condition | Refurbished | ||||
| Warranty | 1 Year Full Replacement Warranty Included |