Eaton Powerware UPS 9135 6000VA 4200W RM 3U 208/230V, PW9135G6000-XL3U - Refurbished

Eaton Powerware 9135 6000VA 4200W RM 3U, Online Double Conversion UPS
Model: PW9135G6000-XL3U
6000VA / 4200W, 3U, 200-240V, 208V
Input: NEMA L6-30P (208–240 V) with hardwired option 

Output: (4) L6-30R
Refurbished with New Batteries
Double Conversion Online UPS with internal hot-swappable batteries
1 Year Extended Warranty Included

In stock

Manufacturer: Eaton Powerware
Model: Eaton Powerware 9135 6000VA 4200W RM 3U, 208V-240V
Condition: New Batteries, Refurbished UPS
Part Number: PW9135G6000-XL3U
Maximum output: 4200W / 6000VA

Warranty: 1 Year Extended Warranty, additional warranty available

Description: The PW9135G6000-XL3U Eaton Powerware 9135 is a 6000VA online double-conversion UPS designed for high-performance power protection. This refurbished unit is equipped with new batteries to ensure reliable runtime and optimal performance. It supports 208–240V operation, includes rackmount 3U form factor, and delivers clean sine wave output for critical equipment. Covered by a one-year replacement warranty, with extended warranty options available up to 3 years. for added protection..

 

Eaton Powerware 9135 6000VA 4200W - User Manual

 


PW9135G6000-XL3U Specifications:

General

Topology

Double-conversion

Catalog Number

PW9135G6000-XL3U

Rating (VA/Watts)

6000VA / 4200W

Dimensions (H x W x D, inches)

5.14 x 17.5 x 29.2

Weight (lbs)

125.7

Contents

(Ships with the following items)

- No accessories included

Nominal Input Voltage

208V (U Model) / 230V (EU Model)

Input Voltage Range

156–280V

Input Frequency Range

40–70 Hz (±0.2 Hz)

AC Output on Battery Power

208V 60 Hz (U Model) / 230V 50 Hz (EU Model)

Transfer Time

Adjustable (front panel)

 


Electrical Input

Connection

(1) NEMA L6-30P 
or Hardwired 

Input Cord

6 ft power cord

Nominal Voltage

200V (10% derating of output power) 208/220/230/240/250V. The default nominal voltage is 208V.

   

Electrical Output

Output Receptacles

(4) NEMA L6-30R
Hardwired - see manual for terminal block layout


Environmental & Standards

Heat Dissipation (BTU)

Normal: 1350, Battery: 1960, High Efficiency: 450

Operating Temperature

0°C – 40°C (32°F – 104°F)

Storage Temperature

−25°C – 40°C (−13°F – 104°F)

Relative Humidity

5–95% non-condensing

Operating Altitude

Up to 1,000 m above sea level

Audible Noise

<46 dBA (Normal/Battery Mode)

Surge Suppression

ANSI C62.41 Category B, IEC 61000-4-5

Safety markings

UL, NOM, NYCE

EMC Markings