1-866-311-1945 sales@excessups.com

United States United States [change]
10% Off

Liebert Online Double Conversion RM 4U UPS GXT2-6000RT208

GXT2-6000RT208 Refurbished Liebert Online Double Conversion Rackmount 4U UPS 
6000VA / 4200W 120/208V
Refurbished with New Batteries

Availability: In stock

Msrp Price: $2,199.99

Now only: $1,984.99

Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Liebert
Model: GXT2-6000RT208 Liebert Online Double Conversion Rackmount 4U UPS 
Condition: Refurbished with New Batteries
Part Number: GXT2-6000RT208
Warranty: 1 Year Full Replacement Warranty, additional warranty available

The GXT2-6000RT208 comes refurbished with new batteries. The Liebert UPS comes with a one year replacement warranty. Additional warranty of up to 3 years is available for your convenience.

  • True On Line (Double Conversion) Technology
  • User replaceable batteries without removing GXT2 from rack
  • Wide input voltage window allows UPS support without going to battery, extending systems availability
  • Built in Surge Suppression
  • SNMPE3 compatible
  • External plug and play, 2U battery cabinets available
  • Configurable as rack or tower Specifications

GXT2-6000RT208 Specifications:

Output

  • Capacity 6000VA (4200 Watts)
  • Nominal Voltage 120/208 VAC
  • L1-L2 Factory default output phase angle: 120 Degrees
  • Allowable output phase angle: 120, 180 or 240 Degrees, auto-sending on initial application of AC
  • Factory default L1-N, L2-N VAC: 120 VAC
  • User configurable L1-N, L2-N VAC: 100, 110, 115, 120, 127 VAC +/- 3%
  • Output connections:Frequency 50/60 Hz
    • (1) L6-30R
    • (1) L6-30R
    • (4) 5-20R (Standard 120V 3-prong receptacles will also accept 20Amp straight plug also known as “T” plug)
  • Waveform Sinewave

Input

  • Input Voltage 120/208 VAC at 120 degrees
  • Frequency 50/60 Hz
  • L1-L2 Input Phase Angle 120 Degrees
  • Allowable Input Phase Angle 120, 180, 240 degrees. Auto sensing on application of AC.
  • Factory default L1-N, L2-N VAC: 120 VAC Nominal
  • User configurable L1-N, L2-N VAC: 100, 110, 115, 120, 127 VAC
  • Input power connection: L14-30P

Batteries

  • Type Valve-regulated non-spillable, flame-retardant, sealed lead-acid batteries
  • Runtime at full load (4200 Watts) 5 minutes
  • Runtime at 75% load (3150 Watts) 8 minutes
  • Runtime at 50% load (2100 Watts) 14 minutes
  • Runtime at 25% load (1050 Watts) 32 minutes
  • Runtime at minimal load (420 Watts) 75 minutes
  • Replacement battery kit URBC120912
  • Recharge Time 6 hours to 90% capacity
  • External Battery Cabinet for extended runtime capability GXT2-144VBATT

Physical

  • Width 16.9 inches (430 mm)
  • Depth 24.2 inches (615 mm)
  • Height 6.9 inches (4U) (176 mm)
  • Weight 146 lbs. (66.1 Kg)
  • Audible Noise <50 dBA at 1 meter from front or sides

Copmpliance

  • UL 1778
  • c-UL Listed
  • FCC Part 15 Subpart B Class A
  • IEEE/ANSI C62.41 Category A & B
  • ISTA Procedure 1A


Additional Info