Powervar ABCDEF 8000VA 7200W Online Double-Conversion Tower UPS
Model: ABCDEF8000-22
Input: Hardwired, 200/208/220/230/240V AC
Output: Hardwired, Voltage Depends on Configuration
Maximum Output: 8000VA / 7200W
True Online Double-Conversion UPS
IGBT Technology with Internal Isolation Transformer
288VDC Nominal Battery System
Compatible with D28848-22 External Battery Cabinets
Optional Internal SNMP Network Management Adapter
New Batteries, Refurbished UPS
1 Year Replacement Warranty Included
In stock
Manufacturer: Powervar
Model: POWERVAR ABCDEF 8000VA 7200W Online Double-Conversion Tower UPS
Part Number: ABCDEF8000-22
Condition: New Batteries, Refurbished UPS
Maximum Output: 7200W / 8000VA
Typical Backup Time at Half Load: 25 Minutes (3600W)
Typical Backup Time at Full Load: 10 Minutes (7200W)
Input: Hardwired, 200/208/220/230/240V AC
Output: Hardwired, Voltage Depends on Configuration
Topology: True Online Double-Conversion
Isolation: Internal Isolation Transformer
Battery Configuration: (24) 12V Sealed Lead-Acid Batteries
Nominal Battery Voltage: 288VDC
Extended Runtime: Compatible with D28848-22 External Battery Cabinets
Communications: RS-232, USB, DB-9 Dry Contacts
Network Management: Optional Internal SNMP Adapter
Form Factor: Floor-Standing Tower
Warranty: 1 Year Replacement Warranty
Â
Â
Â
Powervar ABCDEF 8000VA 7200W Online Double-Conversion Tower UPS User ManualÂ
Â
Â
Â
 ABCDEF8000-22 - Powervar ABCDEF 8000VA 7200W Specifications:
Â
| General | Â |
| Manufacturer | POWERVAR |
| Model | ABCDEF8000-22 |
| Product Family | POWERVAR ABCDEF 8000 |
| Product Type | Uninterruptible Power Supply (UPS) |
| Maximum Output | 8000VA / 7200W |
| UPS Topology | True Online Double-Conversion |
| Power Conversion Technology | IGBT Design |
| Isolation Transformer | Internal |
| Output Power Factor | 0.9 |
| Form Factor | Floor-Standing Tower |
| Condition | Refurbished UPS |
| Â | Â |
| Electrical Input | Â |
| Input Voltage Options | 200 / 208 / 220 / 230 / 240V AC |
| Input Voltage Range at 200V | 140–230V AC |
| Input Voltage Range at 208V | 146–239V AC |
| Input Voltage Range at 220V | 154–253V AC |
| Input Voltage Range at 230V | 161–264V AC |
| Input Voltage Range at 240V | 168–276V AC |
| Input Voltage Tolerance | +15% / -30% Before Battery Operation |
| Input Frequency | 50/60Hz |
| Input Frequency Tolerance | 42–69Hz |
| Input Power Factor | Greater Than 0.95 |
| Input Current THD | Less Than 5% |
| Input Connection | Hardwired Standard |
| Optional Input Cord | Factory-Configured Option |
| Â | Â |
| Electrical Output | Â |
| Output Capacity | 8000VA / 7200W |
| Output Voltage Options | 200 / 120-208-240 / 220 / 230V AC, Depending on Configuration |
| Output Voltage Regulation | ±3% Maximum; ±1% Normal |
| Output Voltage THD | Less Than 3% |
| Output Frequency | 50/60Hz |
| Output Frequency Regulation | ±0.1Hz |
| Crest Factor | 3:1 |
| Output Power Factor | 0.9 |
| Overload at 125% | 2 Minutes |
| Overload at 150% | 30 Seconds |
| Overload at 300% | 500 ms |
| AC-to-AC Efficiency | Greater Than 87% |
| DC-to-AC Efficiency | Greater Than 83% |
| Common Mode Noise | Less Than 0.5Vrms |
| Output Connection | Hardwired Standard |
| Optional Output Receptacles | Factory-Configured Option |
| Â | Â |
| Bypass | Â |
| Bypass Capability | Yes |
| Transformer Voltage Regulation | ±3% |
| Bypass Overload at 125% | 10 Minutes |
| Bypass Overload at 150% | 500 ms |
| Bypass Overload at 1000% | 1 Cycle |
| Bypass Efficiency | Greater Than 95% |
| Â | Â |
| Battery & Runtime | Â |
| Battery Technology | Sealed Lead-Acid |
| Internal Battery Quantity | 24 |
| Battery Rating | 12V, 34W High-Rate, Flame-Retardant |
| Nominal Battery Voltage | 288VDC |
| Float Battery Voltage | 327.6VDC |
| Battery Charging Current | 2.5A DC |
| Recharge Time | 8 Hours to 90% |
| Backup Time at 25% Load (1800W) | 65 Minutes |
| Backup Time at 50% Load (3600W) | 25 Minutes |
| Backup Time at 75% Load (5400W) | 15 Minutes |
| Backup Time at 100% Load (7200W) | 10 Minutes |
| External Battery Expansion | Supported |
| Compatible External Battery Cabinet | D28848-22 |
| External Battery Cabinet Configuration | 2 Strings × 24 Batteries (48 Batteries) |
| External Battery Cabinets Included | No |
| Â | Â |
| Communications & Management | Â |
| RS-232 Communication | Yes |
| USB Communication | Yes |
| DB-9 Dry Contacts | Yes |
| Internal SNMP Adapter | Optional |
| Network Management | Available with Optional SNMP Adapter |
| Â | Â |
| Physical | Â |
| Mounting Type | Floor-Standing |
| Unit Weight | 449 lbs (203.7 kg) |
| Shipping Weight | 641.5 lbs (291 kg) |
| Approximate Height | 33.46 in (850 mm) |
| Approximate Width | 13.77 in (349.76 mm) |
| Approximate Depth | 38.61 in (980.61 mm) |
| Â | Â |
| Environmental | Â |
| Operating Temperature | 0°C to 40°C |
| Transit Temperature | -20°C to 60°C |
| Operating Altitude | Up to 2,000 m |
| Transit Altitude | Up to 12,000 m |
| Relative Humidity | 5–90%, Non-Condensing |
| Audible Noise | 55–60 dBA at 1 Meter |
| Heat Dissipation | 4,239 BTU/hr |
| Â | Â |
| Certifications & Compliance | Â |
| Safety Standards | UL 1778, 4th Edition; cUL to CSA 22.2 No. 107.1 |
| International Safety | IEC 62040 |
| EMC Compliance | FCC Part 15J Class A, EN 55022 Class A, CISPR 22 |
| Immunity Standards | IEC 61000 Series |
| RoHS Compliance | Yes |
| Â | Â |
| Condition & Warranty | Â |
| UPS Condition | Refurbished |
| Battery Condition | New Batteries |
| Warranty | 1 Year Replacement Warranty |