Tripp Lite HC150SL Medical Power Inverter/Charger 150W
Model: HC150SL
Input: IEC C14 (120V AC)
Output: (1) IEC C13
Medical-Grade Power Inverter/Charger – Pure Sine Wave Output
Refurbished Unit
1 Year Warranty Included
In stock
Manufacturer: Tripp Lite
Model: HC150SL Medical Power Inverter/Charger 150W, 120V
Condition: Refurbished Unit
Part Number: HC150SL
Maximum Output: 150W Continuous / 225W Peak
Output Voltage: 120V AC – Pure Sine Wave
DC System Voltage: 12V
Battery Compatibility: SLA or LiFePO4 Batteries
Typical Runtime: Up to 6 hours depending on battery condition and load
Warranty: 1 Year Warranty Included
Tripp Lite HC150SL Medical Power Inverter/Charger 150W 120V - User Manual
Tripp Lite HC150SL Medical Power Inverter/Charger – Specs
|
Main |
|
|
Main Input Voltage |
120V AC |
|
Main Output Voltage |
120V AC |
|
Rated Power |
150W continuous / 225W peak |
|
Input Connection Type |
IEC C14 |
|
Output Connection Type |
(1) IEC C13 |
|
Number of Rack Units |
N/A – Mobile Cart / Standalone |
|
Cable Length |
0.5 ft (0.15 m) |
|
Battery Type |
SLA or LiFePO4 |
|
Batteries & Runtime |
|
|
Expandable Runtime |
Yes |
|
Included Battery Modules |
Internal Hot-Swappable Battery |
|
Battery Life |
Depends on battery chemistry and usage |
|
Battery Charge |
Advanced 3-stage charger (9–20A) |
|
Typical Runtime |
Up to 6 hours (varies with load and battery condition) |
|
General |
|
|
Product Use |
Mobile medical cart power module |
|
Redundant / Extended Run |
Optional with external batteries |
|
USB Compatible |
Yes |
|
Physical |
|
|
Color |
Gray |
|
Dimensions (H×W×D) |
3.5 × 11.5 × 6 in (8.9 × 29.2 × 15.2 cm) |
|
Net Weight |
14 lbs (6.35 kg) |
|
Mounting Location |
Cart-mounted / standalone |
|
Cooling Method |
Fan |
|
Input |
|
|
Voltage Range |
120V AC nominal |
|
Input Frequency |
60 Hz |
|
Output |
|
|
Waveform Type |
Pure Sine Wave |
|
Frequency |
60 Hz |
|
Maximum Power |
150W continuous / 225W peak |
|
Transfer Time |
Zero transfer time (continuous operation) |
|
Conformance & Certifications |
|
|
IEC 60601-1 |
Yes |
|
CAN/CSA-C22.2 No. 601.1 |
Yes |
|
UL 1778 |
Yes |
|
RoHS Compliant |
Yes |
|
Environmental |
|
|
Operating Temperature |
32–104 °F (0–40 °C) |
|
Storage Temperature |
14–122 °F (-10–50 °C) |
|
Relative Humidity |
0–90% non-condensing |
|
Storage Relative Humidity |
0–95% non-condensing |
|
Operating Altitude |
0–10,000 ft (0–3,000 m) |
|
Communications & Management |
|
|
USB Communication Interface |
Yes |
|
Optional Remote User Interface (RUI) |
AC output and battery status |
|
PowerAlert software |
Monitoring and logging |
|
Audible low battery alarm |
Yes |
|
Surge & Noise Suppression |
|
|
EMI / RFI AC noise filtering |
Yes |
|
Protects sensitive medical electronics |
From line interference |