Tripp Lite SmartPro 3000VA 2250W RM 2U 120V
Model: SMART3000RM2U
Input: NEMA L5-30P (120V - 30A)
Output: (8) NEMA 5-15/20R, (1) NEMA L5-30R
Line-Interactive UPS - Pure Sine Wave Output
Automatic Voltage Regulation (AVR)
Extended Runtime - External Battery Pack Compatible
Optional Network Management Card
USB, DB9 Serial & EPO Connectivity
Integrated Switched PDU - (3) Individually Controllable Load Banks
New Batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro 3000VA 2250W Line-Interactive UPS, Rackmount 2U, 120V, 30A
Condition: New Batteries, Refurbished UPS
Part Number: SMART3000RM2U
Maximum Output: 2250W / 3000VA
Typical Backup Time at Half Load: 10 Minutes (1125W)
Typical Backup Time at Full Load: 3 Minutes (2250W)
Input: NEMA L5-30P, 120V, 30A
Output: (8) NEMA 5-15/20R, (1) NEMA L5-30R
Topology: Line-Interactive
Output Waveform: Pure Sine Wave
Extended Runtime: Supports Optional External Battery Packs
Network Management: Optional SNMP / Web Network Management Card
Communications: USB (HID), DB9 Serial, EPO & SNMP/Web Interface Slot
Load Management: (3) Individually Controllable Load Banks
Warranty: 1 Year Full Replacement Warranty
Â
Â
Â
Tripp Lite SmartPro 3000VA 2250W RM 120V SMART3000RM2U - User Manual
Â
Â
Â
Â
SMART3000RM2U - Tripp Lite SmartPro 3000VAÂ Specifications:
| Main | Â | Â |
| Manufacturer | Tripp Lite | Â |
| Product Family | SmartPro | Â |
| Model / Part Number | SMART3000RM2U | Â |
| Product Type | UPS Battery Backup | Â |
| UPS Topology | Line-Interactive | Â |
| Maximum Output | 2250W / 3000VA | Â |
| Output Capacity | 3.0 kVA | Â |
| Power Factor | 0.75 | Â |
| Nominal Input Voltage | 120V AC | Â |
| Nominal Output Voltage | 120V AC | Â |
| Input Phase | Single-Phase | Â |
| Form Factor | Rackmount | Â |
| Rack Height | 2U | Â |
| Extended Runtime | Yes | Â |
| Condition | New Batteries, Refurbished UPS | Â |
| Â | Â | Â |
| Input | Â | Â |
| Nominal Input Voltage | 120V AC | Â |
| Input Connection | NEMA L5-30P | |
| Rated Input Current at Maximum Load | 24A | Â |
| Input Circuit Breaker | 30A | Â |
| Recommended Electrical Service | 30A / 120V | Â |
| Input Cord Length | 10 ft (3.1 m) | Â |
| Input Phase | Single-Phase | Â |
| Input Frequency | 60 Hz | Â |
| Â | Â | Â |
| Output | Â | Â |
| Output VA Capacity | 3000VA | Â |
| Output Watt Capacity | 2250W | Â |
| Output kVA Capacity | 3.0 kVA | Â |
| Output kW Capacity | 2.25 kW | Â |
| Output Power Factor | 0.75 | Â |
| Nominal Output Voltage | 120V | Â |
| Supported Output Voltages | 110V / 115V / 120V | Â |
| Output Frequency | 60 Hz | Â |
| Output Waveform - AC Mode | Pure Sine Wave | Â |
| Output Waveform - Battery Mode | Pure Sine Wave | Â |
| Output Voltage Regulation - Line Mode | -14% / +6% | Â |
| Output Voltage Regulation - Battery Mode | ±5% |  |
| Output Receptacles NEMA 5-15/20R | (8) NEMA 5-15/20R, 120V | |
| Output Receptacles NEMA L5-30R | (1) NEMA L5-30R, 120V | |
| Total Output Outlets | (9) | Â |
| Switchable Load Banks | (3) individually controllable single-outlet load banks | Â |
| Output Circuit Breakers | (2) 20A breakers; each protects (4) NEMA 5-15/20R outlets | Â |
| L5-30R Protection | Unbreakered | Â |
| Output Circuit Breakers | (2) 20A | Â |
| Output Breaker Protection | Each 20A breaker protects (4) NEMA 5-15/20R outlets | Â |
| L5-30R Breaker Protection | Unbreakered | Â |
| Switchable Load Banks | Yes | Â |
| Individually Controllable Load Banks | Yes | Â |
| Load Management Receptacles | Switchable single-outlet load banks | Â |
| Maximum Output with External Battery Packs | 1600W | Â |
| Â | Â | Â |
| Batteries & Runtime | Â | Â |
| Battery Type | Valve-Regulated Lead-Acid (VRLA) | Â |
| DC System Voltage | 48V DC | Â |
| Typical Backup Time at Half Load | 10 minutes at 1125W | Â |
| Typical Backup Time at Full Load | 3 minutes at 2250W | Â |
| Expandable Runtime | Yes | Â |
| External Battery Pack Support | Yes | Â |
| Compatible External Battery Pack | BP48V24-2U, limit (1) | Â |
| Compatible Extended Battery Pack | BP48V60RT-3U, multi-pack compatible | Â |
| Compatible Extended Battery Pack | BP48V27-2US, multi-pack compatible | Â |
| Internal Replacement Battery Cartridge | RBC94-2U | Â |
| Battery Recharge Time | Less than 4.5 hours from 10% to 90% | Â |
| Battery Access | Front-panel battery access door | Â |
| Hot-Swappable Batteries | Yes | Â |
| User-Replaceable Batteries | Yes | Â |
| Â | Â | Â |
| Voltage Regulation | Â | Â |
| Automatic Voltage Regulation (AVR) | Yes | Â |
| AVR Operating Range | 83–145V AC |  |
| Overvoltage Correction | Input voltages from 127–145V are reduced by 12% |  |
| Undervoltage Correction | Input voltages from 96–108V are boosted by 12% |  |
| Severe Undervoltage Correction | Input voltages from 83–95V are boosted by 24% |  |
| Battery Conservation | AVR corrects applicable voltage fluctuations without switching to battery power | Â |
| Â | Â | Â |
| Line / Battery Transfer | Â | Â |
| Transfer to Battery | Automatic during power failure or extreme voltage variation | Â |
| Low-Voltage Transfer Point | 83V | Â |
| High-Voltage Transfer Point | 145V | Â |
| Â | Â | Â |
| Communications & Management | Â | Â |
| Network Management | Optional | Â |
| Network Management Card Included | No | Â |
| Network Management Slot | Slot for optional SNMP / Web interface | Â |
| Compatible Network Management Cards | SNMPWEBCARD, TLNETCARD, WEBCARDLX | Â |
| Relay Interface Card | RELAYIOCARD | Â |
| USB Communication | Yes | Â |
| USB Interface | HID-enabled | Â |
| Serial Communication | DB9 Serial | Â |
| EPO Interface | Yes | Â |
| Local UPS Monitoring | Yes | Â |
| Network Monitoring | Supported with optional network management card | Â |
| Network Monitoring Capability | Detailed monitoring of UPS and site power conditions | Â |
| PowerAlert Software | Supported | Â |
| WatchDog Compatibility | Yes | Â |
| WatchDog Application Restart | Supported | Â |
| WatchDog OS Restart | Supported | Â |
| WatchDog Hard-Reboot | Supported | Â |
| Network UPS Tools (NUT) Compatibility | Yes | Â |
| Remote Load Bank Control | Yes | Â |
| Remote Equipment Reboot | Yes | Â |
| Load Shedding | Yes | Â |
| Â | Â | Â |
| User Interface, Alerts & Controls | Â | Â |
| Front Panel Display | LED Status Display - No LCD | Â |
| LED Indicators | (5) | Â |
| Line Power Indicator | Yes | Â |
| Battery Power Indicator | Yes | Â |
| Overload Indicator | Yes | Â |
| Voltage Regulation Indicator | Yes | Â |
| Low / Replace Battery Indicator | Yes | Â |
| Front Panel Controls | (2) switches | Â |
| ON / OFF Control | Yes | Â |
| Alarm Cancel / Self-Test Control | Yes | Â |
| Audible Alarm | Yes | Â |
| Power Failure Alarm | Yes | Â |
| Overload Alarm | Yes | Â |
| Low-Battery Alarm | Yes | Â |
| Alarm Cancel | Yes | Â |
| Self-Test | Yes | Â |
| Â | Â | Â |
| Power Management Features | Â | Â |
| Integrated Switched PDU | Yes | Â |
| Individually Controllable Load Banks | Yes | Â |
| Remote Outlet Management | Yes | Â |
| Remote Power Cycling | Yes | Â |
| Remote Equipment Reboot | Yes | Â |
| Load Shedding | Yes | Â |
| Current Monitoring | Yes | Â |
| Automatic Self-Test | Yes | Â |
| Cold Start | Yes | Â |
| Automatic Shutdown Support | Yes | Â |
| Hot-Swappable Batteries | Yes | Â |
| High-Efficiency Operation | Yes | Â |
| Â | Â | Â |
| Surge Protection & Filtering | Â | Â |
| AC Surge Suppression | Yes | Â |
| Surge Energy Rating | 570 Joules | Â |
| Surge Suppression Response Time | Instantaneous | Â |
| EMI / RFI AC Noise Suppression | Yes | Â |
| Network-Grade AC Surge Protection | Yes | Â |
| Â | Â | Â |
| Physical | Â | Â |
| Primary Form Factor | Rackmount | Â |
| Rack Height | 2U | Â |
| Rack Standard | 19-inch | Â |
| 4-Post Rackmount | Supported | Â |
| 2-Post Rackmount | Supported with optional mounting accessory | Â |
| Tower Installation | Supported with optional 2-9USTAND | Â |
| Wallmount Installation | Supported with optional mounting accessory | Â |
| Cooling Method | Fan | Â |
| Housing Material | Steel | Â |
| Minimum Rack Depth without External Battery Pack | 24.5 in (62 cm) | Â |
| Minimum Rack Depth with External Battery Pack | 26.5 in (67 cm) | Â |
| UPS Height | 3.43 in (8.71 cm / 87 mm) | Â |
| UPS Width | 17.32 in (43.99 cm / 440 mm) | Â |
| UPS Depth | 19.46 in (49.43 cm / 494 mm) | Â |
| UPS Weight | 62.8 lb (28.49 kg) | Â |
| Â | Â | Â |
| Environmental | Â | Â |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |  |
| Storage Temperature | 5°F to 122°F (-15°C to 50°C) |  |
| Relative Humidity | 0–95%, non-condensing |  |
| Audible Noise | 45 dBA maximum at 1 meter | Â |
| AC Mode Heat Dissipation at Full Load | 189 BTU/hr | Â |
| Battery Mode Heat Dissipation at Full Load | 1356 BTU/hr | Â |
| AC Mode Efficiency at Full Load | 98% | Â |
| Â | Â | Â |
| Conformance | Â | Â |
| UL Certification | UL 1778 | Â |
| CSA Certification | Yes | Â |
| NOM Certification | Yes | Â |
| FCC Compliance | FCC Part 15 | Â |
| RoHS | Compliant | Â |
| Â | Â | Â |
| Packaging | Â | Â |
| Shipping Height | 8.40 in (21.34 cm) | Â |
| Shipping Width | 23.80 in (60.45 cm) | Â |
| Shipping Depth | 21.70 in (55.12 cm) | Â |
| Shipping Weight | 82.0 lb (37.19 kg) | Â |
| Â | Â | Â |
| General | Â | Â |
| Recommended Application | Server, network and telecommunications equipment | Â |
| Automatic Voltage Regulation | Yes | Â |
| Battery Backup | Yes | Â |
| Surge Protection | Yes | Â |
| Extended Runtime Capability | Yes | Â |
| Remote Management Capability | Yes, with optional network management card | Â |
| Integrated Load Management | Yes | Â |
| Rack / Tower Convertible | Yes, tower configuration requires optional stand | Â |
| Â | Â | Â |
| Condition & Warranty | Â | Â |
| Condition | Refurbished UPS | Â |
| Batteries | New Batteries | Â |
| Warranty | 1 Year Full Replacement Warranty | Â |