Tripp Lite Smart Pro 1500VA 900W Tower 120V
Model: SMART1500SLT
Input: NEMA 5-15P (120V - 5A)
Output: (8) NEMA 5-15R
Line-Interactive UPS - Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included
Out of stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 1500VA 900W, Tower, 120V
Condition: New batteries, refurbished UPS
Part Number: SMART1500SLT
Maximum output: 900W / 1500VA
Typical backup time at half load: 20 minutes (450 Watts)
Typical backup time at full load: 8 minutes (900 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 1500VA 900W Tower 120V SMART1500SLT Manual
SMART1500SLT - Tripp Lite SmartPro 1500VA Specifications:
Input:
|
Rated input current (Maximum Load) |
10.1A (100V), 9.3A (110V), 8.6A (120V) |
||
|
Nominal Input Voltage(s) Supported |
100V AC; 110V AC; 120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
15A |
||
|
UPS Input Cord Length (ft.) |
6 |
||
|
UPS Input Cord Length (m) |
1.8 |
||
|
Recommended Electrical Service |
15A 120V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
1500 |
||
|
Output Capacity (kVA) |
1.5 |
||
|
Output Watt Capacity (Watts) |
900 |
||
|
Output Capacity Details |
7.5A @ 120V (default), 8.2A @ 110V, 9A @ 100V. 125% @ 10 minutes 110% +/- 10% @ 5 seconds |
||
|
Power Factor |
0.63 |
||
|
Nominal Voltage Details |
120V sinusoidal in line mode and 120V sinusoidal in battery mode |
||
|
Frequency Compatibility |
50 / 60 Hz |
||
|
Output Voltage Regulation (Line Mode) |
-13%, + 15% |
||
|
Output Voltage Regulation (Battery Mode) |
+/-5% |
||
|
Output AC Waveform (AC Mode) |
Sine wave |
||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||
|
Nominal Output Voltage(s) Supported |
100V; 110V; 120V |
||
|
Output Receptacles |
|
||
|
Individually Controllable Load Banks |
No |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
8 min. (900w) |
|
Half Load Runtime (min.) |
20 min. (450w) |
|
Expandable Runtime |
No |
|
DC System Voltage (VDC) |
36 |
|
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
|
Battery Access |
Battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC36-SLT |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 95 to 145 (120v), 87 to 133 (110v), 83 to 121 (100v) |
|
Overvoltage Correction |
Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v); All voltage setpoints ±5% tolerance |
|
Undervoltage Correction |
Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v); All voltage setpoints ±5% tolerance |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates power failure and overload conditions |
|
LED Indicators |
Status LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level |
|
Site Wiring Fault Indication |
Rear panel site wiring fault LED |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
690 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Tower
|
|
Cooling Method |
Fan
|
|
Installation Form Factors Supported |
Tower
|
|
Primary UPS Depth (mm) |
335
|
|
Primary UPS Height (mm) |
259 |
|
Primary UPS Width (mm) |
173 |
|
Shipping Dimensions (hwd / cm) |
35.31 x 24.64 x 44.70 |
|
Shipping Dimensions (hwd / in.) |
13.90 x 9.70 x 17.60 |
|
Shipping Weight (kg) |
21.82 |
|
Shipping Weight (lbs.) |
48.10 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
25.91 x 17.27 x 33.53 |
|
UPS Power Module Dimensions (hwd, in.) |
10.2 x 6.8 x 13.2 |
|
UPS Power Module Weight (kg) |
20.41 |
|
UPS Power Module Weight (lbs.) |
45 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
148 |
|
Battery Mode BTU / Hr. (Full Load) |
500 |
|
AC Mode Efficiency Rating (100% Load) |
95% |
|
Operating Elevation (ft.) |
6561 ft. (2000 m) above sea level |
|
Audible Noise |
Audible Noise < 50 dBA at Front Side 1 Meter |
Communications:
|
Network Management Cards |
SNMPWEBCARD; WEBCARDLX ; RELAYIOCARD |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network UPS Tools Compatibility |
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled) |