Tripp Lite Smart Pro 1500VA 980W Tower 120V
Model: SMART1500SLT
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Line-Interactive UPS - Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included
Out of stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 1500VA 980W, Tower, 120V
Condition: New batteries, refurbished UPS
Part Number: SMART1500
Maximum output: 980W / 1500VA
Typical backup time at half load: 20 minutes (490 Watts)
Typical backup time at full load: 7 minutes (980 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 1500VA 980W Tower 120V SMART1500 Manual
SMART1500 - Tripp Lite SmartPro 1500VA Specifications:
Input:
|
Rated input current (Maximum Load) |
12A |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
15A |
||
|
UPS Input Cord Length (ft.) |
7 |
||
|
UPS Input Cord Length (m) |
2.1 |
||
|
Recommended Electrical Service |
15A 120V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
1500 |
||
|
Output Capacity (kVA) |
1.5 |
||
|
Output Watt Capacity (Watts) |
980 |
||
|
Output Watt Capacity (Watts) |
980 |
||
|
Nominal Voltage Details |
120v nominal output in battery mode |
||
|
Frequency Compatibility |
60 Hz |
||
|
Output Voltage Regulation (Line Mode) |
-18%, +8% |
||
|
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||
|
Load Management Receptacles |
One switchable single-outlet 5-15R load bank |
||
|
Output AC Waveform (AC Mode) |
Sine wave |
||
|
Output AC Waveform (Battery Mode) |
PWM sine wave |
||
|
Nominal Output Voltage(s)Supported |
110V; 115V; 120V |
||
|
Output Receptacles |
|
||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
7 min. (980w) |
|
Half Load Runtime (min.) |
20 min. (490w) |
|
Expandable Runtime |
No |
|
DC System Voltage (VDC) |
36 |
|
Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
|
Battery Access |
Battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC36-SLT |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 |
|
Overvoltage Correction |
Input voltages between 128 and 147 are reduced by 12% |
|
Undervoltage Correction |
Input voltages between 93 and 107 are boosted by 14% |
|
Severe Undervoltage Correction |
Input voltages between 75 and 92 are boosted by 30% |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status |
|
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
|
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
510 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Tower
|
|
Cooling Method |
Fan
|
|
Installation Form Factors Supported |
Tower
|
|
Installation Form Factors Supported with Optional Accessories |
Wallmount ( UPSWM - tower mounting kit)
|
|
Primary UPS Depth (mm) |
235
|
|
Primary UPS Height (mm) |
324 |
|
Primary UPS Width (mm) |
191 |
|
Shipping Dimensions (hwd / cm) |
43.43 x 28.19 x 33.02 |
|
Shipping Dimensions (hwd / in.) |
17.10 x 11.10 x 13.00 |
|
Shipping Weight (kg) |
18.37 |
|
Shipping Weight (lbs.) |
40.50 |
|
UPS Housing Material |
PVC |
|
UPS Power Module Dimensions (hwd, cm) |
32.38 x 19.05 x 23.50 |
|
UPS Power Module Dimensions (hwd, in.) |
12.75 x 7.5 x 9.25 |
|
UPS Power Module Weight (kg) |
17.69 |
|
UPS Power Module Weight (lbs.) |
39 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
139 |
|
Battery Mode BTU / Hr. (Full Load) |
456 |
|
AC Mode Efficiency Rating (100% Load) |
96% |
Communications:
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management not supported |
|
Communications Interface |
USB; DB9 Serial |