Tripp Lite SmartOnline 1500VA 1200W RM 2U
Model: SU1500RTXL2UA
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Online Double Conversion UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 1500VA 1200W, LCD, RM, 2U, 120V
Condition: New batteries, refurbished UPS
Part Number: SU1500RTXL2UA
Maximum output: 1200W / 1500VA
Typical backup time at half load:14 minutes (600 Watts)
Typical backup time at full load: 5 minutes (1200 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 1500VA 1200W RMÂ 120V SU1500RTXL2UA User's Manual
SU1500RTXL2UA - Tripp Lite SmartOnline 1500VAÂ Specifications:
Input:
|
Rated input current (Maximum Load) |
12A |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
20A |
||
|
UPS Input Cord Length (ft.) |
10 |
||
|
UPS Input Cord Length (m) |
3.1 |
||
|
Recommended Electrical Service |
15A 120V |
||
|
Input Phase |
Single-Phase |
||
|
Input Frequency |
50/60Hz +/-5% |
Output:
|
Output Volt Amp Capacity (VA) |
1500 |
||
|
Output Capacity (kVA) |
1.5 |
||
|
Output Watt Capacity (Watts) |
1200 |
||
|
Output kW Capacity (kW) |
1.2 |
||
|
Output Capacity Details |
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
||
|
Power Factor |
0.8 |
||
|
Crest Factor |
3:1 |
||
|
Frequency Compatibility |
50 / 60 Hz |
||
|
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
||
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
||
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||
|
Load Management Receptacles |
Two switchable 5-15R load banks (bank 1 - two outlets, bank 2 - four outlets) |
||
|
Output AC Waveform (AC Mode) |
Sine wave |
||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||
|
Nominal Output Voltage(s) Supported |
120V |
||
|
Output Receptacles |
|
||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
5 min. (1200w) |
|
Half Load Runtime (min.) |
14 min. (600w) |
|
Expandable Battery Runtime |
Extended runtime supported via optional external battery packs |
|
Expandable Runtime |
Yes |
|
External Battery Pack Compatibility |
BP48V24-2UÂ (limit 1); Â BP48V60RT-3UÂ (multi-pack compatible); Â BP48V27- 2USÂ (multi-pack compatible) |
|
DC System Voltage (VDC) |
48 |
|
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC94-2U |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
|
Overvoltage Correction |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Undervoltage Correction |
Voltage boost of 12% applies when input voltage is between 96 and 108 |
|
Severe Undervoltage Correction |
Voltage boost of 24% applies when input voltage is between 83 and 95 |
User Interface, Alerts & Controls:
|
Switches |
2 switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
|
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
600 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount
|
|
Cooling Method |
Fan
|
|
Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
|
Installation Form Factors Supported: |
4 post 19 inch rackmount & 2 post rack
|
|
Installation Form Factors Optional Accessories |
2 post rackmount (Â 2POSTRMKITWMÂ ); 2-4 post front rail rackmount (Â UPSHDEARKITÂ ); 4 post rackmount short-depth (Â 4POSTRAILKITWMÂ ); Tower (Â 2- 9USTANDÂ ); Wallmount (Â 2POSTRMKITWMÂ )
|
|
Minimum Required Rack Depth with External Battery Pack (cm) |
66
|
|
Minimum Required Rack Depth with External Battery Pack (in.) |
26
|
|
Minimum Required Rack Depth without External Battery Pack (cm) |
56
|
|
Minimum Required Rack Depth without External Battery Pack (in.) |
22
|
|
Optional Mounting Accessory Notes |
Optional  2-9USTAND enables upright tower UPS placement;  2POSTRMKITWM enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support |
|
Primary UPS Depth (mm) |
483 |
|
Primary UPS Height (mm) |
89 |
|
Primary UPS Width (mm) |
445 |
|
Rack Height |
2U |
|
Shipping Dimensions (hwd / cm) |
23.37 x 59.44 x 49.53 |
|
Shipping Dimensions (hwd / in.) |
9.20 x 23.40 x 19.50 |
|
Shipping Weight (kg) |
27.94 |
|
Shipping Weight (lbs.) |
61.60 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
8.89 x 44.45 x 48.26 |
|
UPS Power Module Dimensions (hwd, in.) |
3.5 x 17.5 x 19 |
|
UPS Power Module Weight (kg) |
20.00 |
|
UPS Power Module Weight (lbs.) |
44.1 |
Â
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
612 |
|
AC Economy Mode BTU / Hr. (Full Load) |
216 |
|
Battery Mode BTU / Hr. (Full Load) |
667 |
|
AC Economy Mode Efficiency Rating (100% Load) |
95% |
Communications:
|
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD - Not included |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports , download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |