Tripp Lite SmartOnline 2200VA 1600W RM 2U
Model: SU2200RTXL2UA
Input: NEMA 5-20P (120V - 20A)
Output: (6) NEMA 5-15/20R, (1) NEMA L5-20R
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 2200VA 1600W, RM, 2U, 120V
Condition: New batteries, refurbished UPS
Part Number: SU2200RTXL2UA
Maximum output: 1600W / 2200VA
Typical backup time at half load: 14 minutes (800 Watts)
Typical backup time at full load: 4.5 minutes (1600 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 2200VA 1600W RMÂ 120V SU2200RTXL2UAÂ Manual
SU2200RTXL2UA - Tripp Lite SmartOnline 2200VAÂ Specifications:
Input:
|
Rated input current (Maximum Load) |
16A |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
30A |
||
|
UPS Input Cord Length (ft.) |
10 |
||
|
UPS Input Cord Length (m) |
3.1 |
||
|
UPS Input Cord Length Details |
Built-in |
||
|
Recommended Electrical Service |
20A 120V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
2200 |
||||
|
Output Capacity (kVA) |
2.2 |
||||
|
Output Watt Capacity (Watts) |
1600 |
||||
|
Output kW Capacity (kW) |
1.6 |
||||
|
Output Capacity Details |
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
||||
|
Power Factor |
0.7 |
||||
|
Crest Factor |
3:1 |
||||
|
Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode |
||||
|
Frequency Compatibility |
50 / 60 Hz |
||||
|
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
||||
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
||||
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||||
|
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||||
|
Load Management Receptacles |
Two switchable three-outlet 5-15/20R load banks |
||||
|
Output AC Waveform (AC Mode) |
Sine wave |
||||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
|
Nominal Output Voltage(s) Supported |
120V |
||||
|
Output Receptacles |
|
||||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
4.5 min. (1600w) |
|
Half Load Runtime (min.) |
14 min. (800w) |
|
Expandable Runtime Description |
 BP48V24-2U (limit 2 w/  48VDCSPLITTER ) |
|
External Battery Pack Compatibility |
BP48V24-2UÂ (limit 1); Â BP48V60RT-3UÂ (multi-pack compatible); Â BP48V27- 2USÂ (multi-pack compatible) |
|
DC System Voltage (VDC) |
48 |
|
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
 RBC94-2U |
|
Battery Replacement Description |
Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioningf |
|
Overvoltage Correction |
2% output voltage regulation during overvoltages to 150 |
|
Undervoltage Correction |
2% output voltage regulation during undervoltages to 80 |
|
Severe Undervoltage Correction |
2% output voltage regulation during undervoltages to 65 (under 70% load only) |
User Interface, Alerts & Controls:
|
Switches |
2 switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
|
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
570 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount
|
|
Cooling Method |
Fan
|
|
Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
|
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount
|
|
Installation Form Factors Supported with Optional Accessories |
2 post rackmount (Â 2POSTRMKITWMÂ ); 2-4 post front rail rackmount (Â UPSHDEARKITÂ ); 4 post rackmount short-depth (Â 4POSTRAILKITWMÂ ); Tower (Â 2- 9USTANDÂ ); Wallmount (Â 2POSTRMKITWMÂ )
|
|
Minimum Required Rack Depth with External Battery Pack (cm) |
66
|
|
Minimum Required Rack Depth with External Battery Pack (in.) |
26
|
|
Minimum Required Rack Depth without External Battery Pack (cm) |
61
|
|
Minimum Required Rack Depth without External Battery Pack (in.) |
24 |
|
Optional Mounting Accessory Notes |
Optional  2-9USTAND enables upright tower UPS placement;  2POSTRMKITWM enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support |
|
Primary UPS Depth (mm) |
483 |
|
Primary UPS Height (mm) |
89 |
|
Primary UPS Width (mm) |
445 |
|
Rack Height |
2U |
|
Shipping Dimensions (hwd / cm) |
23.11 x 51.05 x 59.18 |
|
Shipping Dimensions (hwd / in.) |
9.10 x 20.10 x 23.30 |
|
Shipping Weight (kg) |
28.12 |
|
Shipping Weight (lbs.) |
62.00 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
8.89 x 44.45 x 48.26 |
|
UPS Power Module Dimensions (hwd, in.) |
3.5 x 17.5 x 19 |
|
UPS Power Module Weight (kg) |
21.50 |
|
UPS Power Module Weight (lbs.) |
47.4 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
816 |
|
AC Economy Mode BTU / Hr. (Full Load) |
169 |
|
Battery Mode BTU / Hr. (Full Load) |
889 |
|
AC Economy Mode Efficiency Rating (100% Load) |
94% |
|
Audible Noise |
< 45dB at 1m |
Communication:
|
Network Management Cards |
SNMPWEBCARD; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD - Optional
|
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |