Tripp Lite SmartOnline 3000VA 2400W RM 3U
Model: SU3000RTXR3UJB
Input:Â Hardwire (120V - 24A)
Output:Â Hardwire
Online Double Conversion UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline 3000VA 2400W, RM, 3U, 120V
Condition: New batteries, refurbished UPS
Part Number: SU3000RTXR3UJB
Maximum output: 2400W / 3000VA
Typical backup time at half load: 30 minutes (1200 Watts)
Typical backup time at full load: 12 minutes (2400 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 3000VA 2400W RM 120V SU3000RTXR3UJB Manual
SU3000RTXR3UJB - Tripp Lite SmartOnline 3000VA Specifications:
Input:
|
Rated input current (Maximum Load) |
24A |
||
|
Nominal Input Voltage(s) Supported |
110V AC; 120V AC |
||
|
UPS Input Connection Type |
|
||
|
Recommended Electrical Service |
30A 120V |
Output:
|
Output Volt Amp Capacity (VA) |
3000 |
||
|
Output Capacity (kVA) |
3 |
||
|
Output Watt Capacity (Watts) |
2400 |
||
|
Output kW Capacity (kW) |
2.4 |
||
|
Power Factor |
0.8 |
||
|
Crest Factor |
3:1 |
||
|
Nominal Voltage Details |
120V default |
||
|
Frequency Compatibility |
50 / 60 Hz |
||
|
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
||
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
||
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||
|
Output AC Waveform (AC Mode) |
Sine wave |
||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||
|
Nominal Output Voltage(s) Supported |
110V; 120V |
||
|
Output Receptacles |
|
Battery:
|
Full Load Runtime (min.) |
12 min. (2400w) |
|
Half Load Runtime (min.) |
30 min. (1200w) |
|
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
|
External Battery Pack Compatibility |
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible) |
|
DC System Voltage (VDC) |
72 |
|
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC96-3U (quantity 2) |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
|
Overvoltage Correction |
2% output voltage regulation during overvoltages to 150 |
|
Undervoltage Correction |
2% output voltage regulation during undervoltages to 80 |
|
Severe Undervoltage Correction |
2% output voltage regulation during undervoltages to 65 (under 70% load only) |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
|
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
480 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount
|
|
Cooling Method |
Fan
|
|
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount
|
|
Installation Form Factors Supported with Optional Accessories |
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
|
|
Optional Mounting Accessory Notes |
Wallmount installation not recommended
|
|
Primary UPS Depth (mm) |
749
|
|
Primary UPS Height (mm) |
132
|
|
Primary UPS Width (mm) |
452 |
|
Rack Height |
3U |
|
UPS Housing Material |
Steel |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
1112.7 |
|
AC Economy Mode BTU / Hr. (Full Load) |
520.9 |
|
Battery Mode BTU / Hr. (Full Load) |
1219.3 |
|
AC Mode Efficiency Rating (100% Load) |
88% |
|
AC Economy Mode Efficiency Rating (100% Load) |
94% |
Communications:
|
Network Monitoring Port Description |
SNMPWEBCARD network accessory included; Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
|
PowerAlert Software |
Included |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Communications Interface |
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface |