Tripp Lite SmartOnline 3000VA 2500W RM 2U
Model: SUINT3000RTXL2U
Input: C20 (230V - 15A)
Output: (8) C13, (2) C19
Online Double Conversion UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite Smart Online 3000VA 2500W, RM, 2U, 230V
Condition: New batteries, refurbished UPS
Part Number: SUINT3000RTXL2U
Maximum output: 2500W / 3000VA
Typical backup time at half load:Â 15 minutes (1250 Watts)
Typical backup time at full load: 6Â minutes (2500 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 3000VA 2500W RMÂ 230V SUINT3000RTXL2UÂ Manual
SUINT3000RTXL2U - Tripp Lite SmartOnline 3000VAÂ Specifications:
Input:
|
Rated input current (Maximum Load) |
15A |
||
|
Nominal Input Voltage(s) Supported |
230V AC |
||
|
Nominal Input Voltage Description |
230V Factory Configuration |
||
|
UPS Input Connection Type |
|
||
|
UPS Input Cord Length (ft.) |
5 |
||
|
UPS Input Cord Length (m) |
1.5 |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Capacity (VA) |
3000 |
||
|
Output Capacity (kVA) |
3 |
||
|
Output Capacity (Watts) |
2500 |
||
|
Output Capacity (kW) |
2.5 |
||
|
Output Capacity Details |
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits of ±10% and ±5Hz) or SHUTDOWN (when bypass input voltage and frequency are OUTSIDE bypass limits of ±10% and ±5Hz) |
||
|
Power Factor |
0.83 |
||
|
Crest Factor |
3:1 |
||
|
Nominal Voltage Details |
230V default |
||
|
Frequency Compatibility |
50 / 60 Hz |
||
|
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 50 Hz on cold-start |
||
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
||
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||
|
Included Output Power Cables |
Not included |
||
|
Load Management Receptacles |
Two switchable 4 C13 outlet load banks |
||
|
Hot-Swap PDU options |
PDUBHV20 (2U / 6 C13, 2 C19 outlets) - Not included |
||
|
Output AC Waveform (AC Mode) |
Sine wave |
||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||
|
Nominal Output Voltage(s) Supported |
230V |
||
|
Output Receptacles |
|
||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Runtime Full Load (min.) |
6 |
|
Runtime Half Load (min.) |
15 |
|
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
|
Expandable Runtime |
Yes |
|
External Battery Pack Compatibility |
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) |
|
DC System Voltage (VDC) |
72 |
|
Battery Recharge Rate (Included Batteries) |
Less than 4.8 hours from 10% to 90% (typical, full load discharge) |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
See RBC Selector |
|
Battery Replacement Description |
Hot-swappable, replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
|
Overvoltage Correction |
2% output voltage regulation during overvoltages to 288 |
|
Undervoltage Correction |
2% output voltage regulation during undervoltages to 160V (70-100% load) / 130V (30-70% load) / 100V (Under 30% load) |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation |
|
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
570 |
|
EMI / RFI AC Noise Suppression |
Yes |
|
AC Suppression Response Time |
Instantaneous |
Physical:
|
Primary Form Factor |
Rackmount
|
|
Rack Height |
2U
|
|
Cooling Method |
Fan
|
|
Included Mounting Accessory Description |
Not Included
|
|
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount
|
|
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM ) - Not included
|
|
Minimum Required Rack Depth (cm) |
69.22
|
|
Minimum Required Rack Depth with External Battery Pack (cm) |
77
|
|
Minimum Required Rack Depth with External Battery Pack (in.) |
30.25
|
|
Minimum Required Rack Depth without External Battery Pack (cm) |
75
|
|
Minimum Required Rack Depth without External Battery Pack (in.) |
29.5
|
|
Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support - Not included
|
|
Primary UPS Depth (mm) |
616 |
|
Primary UPS Height (mm) |
88 |
|
Primary UPS Width (mm) |
438 |
|
UPS Power Module Dimensions (hwd, cm) |
8.79 x 43.79 x 61.60 |
|
UPS Power Module Weight (kg) |
31.17 |
|
UPS Housing Material |
Steel |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
|
Relative Humidity |
5 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
742 |
|
AC Mode Efficiency Rating (100% Load) |
92% |
Communications:
|
Network Management Cards |
WEBCARDLX - Not included |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |