Tripp Lite SmartOnline UPS 750VA 600W RM 2U 120V SU750RTXL2U - Refurbished

Tripp Lite SmartOnline 750VA 600W RM 2U
Model: SU750RTXL2U
Input: NEMA 5-15P (120V - 15A)
Output: (6) NEMA 5-15R
Online Double Conversion UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Back Order

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 750VA 600W, RM, 15A, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SU750RTXL2U

Maximum output: 600W / 750VA
Typical backup time
at half load: 11 minutes (300 Watts)
Typical backup time
at full load: 3.99 minutes (600 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 750VA 600W RM 120V SU750RTXL2U Manual


SU750RTXL2U - Tripp Lite SmartOnline 750VA Specifications:

Input:

Rated input current (Maximum Load)

8.6A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-15P

Input Circuit Breakers

15A

UPS Input Cord Length (ft.)

6

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

750

Output Capacity (kVA)

0.75

Output Watt Capacity (Watts)

600

Output Capacity Details

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)

Power Factor

0.8

Crest Factor

3:1

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable single-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V

Output Receptacles

(6) NEMA 5-15R

Individually Controllable Load Banks

 Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

4 min. (600w)

Half Load Runtime (min.)

11 min. (300w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

Expandable Runtime

Yes

External Battery Pack Compatibility

BP24V15RT2U  (limit 1);  BP24V28-2U  (limit 1);  BP24V70-3U  (multi-pack compatible);  BP24V36-2US  (multi-pack compatible)

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC92-2U

Battery Replacement Description

Hot-swappable, user replaceable batteries


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 80

Severe Undervoltage Correction

2% output voltage regulation during undervoltages to 65 (under 70% load only)


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

LED Indicators

14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

480

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Included Mounting Accessory Description

Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); 2-4 post front rail rackmount ( UPSHDEARKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND ); Wallmount ( 2POSTRMKITWM )

Minimum Required Rack Depth (inches)

16.5

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement;  2POSTRMKITWM  enables wall-mount and 2-post rackmount installation;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm);  UPSHDEARKIT  enables installation in 2 or 4-post racks using front vertical rails only, without rear support

Primary UPS Depth (mm)

343

Primary UPS Height (mm)

89

Primary UPS Width (mm)

445

Rack Height

2U

Shipping Dimensions (hwd / in.)

9.10 x 23.30 x 19.60

Shipping Weight (lbs.)

41.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, in.)

3.5 x 17.5 x 13.5

UPS Power Module Weight (kg)

13.15

UPS Power Module Weight (lbs.)

29


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

279

Battery Mode BTU / Hr. (Full Load)

333

AC Mode Efficiency Rating (100% Load)

87%

AC Economy Mode Efficiency Rating (100% Load)

97%


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD 

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)