Tripp Lite SmartOnline UPS 1500VA 1440W RM 1U 20A SU1500LCD1UÂ
Model: SU1500LCD1UÂ
Input: NEMA 5-15P (120V - 20A)
Output: (5) NEMA 5-15
Double-Conversion UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 1500VA 1440W RM 1U 20A
Condition: New batteries, refurbished UPS
Part Number: SU1500LCD1UÂ
Maximum output: 800W / 1000VA
Typical backup time at half load:14 minutes (400 Watts)
Typical backup time at full load: 4 minutes (1440 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline  1500VA 1440W RM 1U 120V SU1500LCD1U - User Manual
SU1500LCD1UÂ - Tripp Lite SmartPro 1000VA Specifications:
Input:
|
Rated input current (Maximum Load) |
913A (100V); 12A (120V); 11.3A (127V)A |
||
|
Nominal Input Voltage(s) Supported |
100V AC; 120V AC; 127V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
20A |
||
|
Recommended Electrical Service |
15A 120V |
||
|
Input Phase |
Single-Phase |
||
|
Input Cord Length (ft.) |
6 ft. |
||
|
Input Cord Length (m) |
1.8 m |
Output:
|
Output Volt Amp Capacity (VA) |
1440 VA |
||
|
Output Capacity (kVA) |
1440 W |
||
|
Output Watt Capacity (Watts) |
800 |
||
|
Power Factor |
1.0 |
||
|
Nominal Voltage Details |
120V (factory-default nominal voltage) |
||
|
Frequency Compatibility |
50 / 60 Hz; supports conversion between 50↔60 Hz |
||
|
Output Voltage Regulation (Line Mode) |
±3% |
||
|
Output Voltage Regulation (Battery Mode) |
±3% |
||
|
Load Management Receptacles |
Two switchable NEMA 5-15R outlet banks Bank 1: 2 outlets Bank 2: 3 outlets |
||
|
Output AC Waveform (AC Mode) |
Pure Sine wave |
||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||
|
Nominal Output Voltage(s) Supported |
100V; 120V; 127V |
||
|
Output Receptacles |
|
||
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
3 min. (a 1440W) |
|
Half Load Runtime (min.) |
10 min. (a 720W) |
|
DC System Voltage (VDC) |
48VDC |
|
Battery Recharge Rate (Included Batteries)Â |
Less than 8 hours to recharge to 90% (typical, full load discharge) |
|
Battery Access |
Hot-swappable, user-replaceable batteries |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
|
Expandable Runtime |
Yes, with compatible external battery packs |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning maintains 3% output voltage regulation during brownouts and overvoltages. |
|
Overvoltage Correction |
Corrects overvoltages to 150V |
|
Undervoltage Correction |
Corrects undervoltages to 50V |
User Interface, Alerts & Controls:
|
Switches |
2 switches control on/off power status and alarm-cancel operation. |
|
Alarm Cancel Operation |
Power-fail alarm can be temporarily silenced using the alarm cancel switch. |
|
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions, UPS fault conditions. |
|
LED Indicators |
 - Green LED: AC Output Status  - Red LED: Shutdown or fault condition |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
540 J |
|
AC Suppression Response Time |
Instantaneous |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Cooling Method |
Fan |
|
Included Mounting Accessory Description |
Includes 4-post rackmount installation accessories |
|
Installation Form Factors Supported with Included Accessories |
4-post 19-inch rackmount |
|
Minimum Required Rack Depth (cm) |
79 cm |
|
Minimum Required Rack Depth (inches) |
30.95 in. |
|
Optional Mounting Accessory Notes |
Included mounting brackets support front-to-rear rail distances of 635 to 914 mm |
|
Primary Form Factor |
Rackmount |
|
Primary UPS Depth (mm) |
710 mm |
|
Primary UPS Height (mm) |
44 mm |
|
Primary UPS Width (mm) |
440 mm |
|
Rack Height |
1U |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
4.4 × 44 × 71 cm |
|
UPS Power Module Dimensions (hwd, in.) |
1.73 × 17.32 × 27.95 in. |
|
UPS Power Module Weight (kg) |
20.50 kg |
|
UPS Power Module Weight (lbs.) |
45.19 lbs. |
Environmental:
|
Operating Temperature Range |
+32° to 104°F (0° to 40°C)
|
|
Storage Temperature Range |
+5° to 122°F (-15° to 50°C) |
|
Relative Humidity |
5% to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
545.92 BTU/hr |
|
Battery Mode BTU / Hr. (Full Load) |
799 BTU/hr |
|
AC Mode Efficiency Rating (100% Load) |
90% |
|
Audible Noise |
65 dBA at 1 meter (front side) |
Communications:
|
Network Management Cards |
WEBCARDLXE |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert |
|
Communications Cable |
Includes USB and RS232 cables |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; Emergency Power Off (EPO); RS-232; USB (HID enabled); Slot for SNMP/Web interface |