Tripp Lite SmartPro 2200VA 1600W Tower
Model: SMART2200SLT
Input: NEMA 5-20P (120V - 20A)
Output: (6) NEMA 5-15/20R, (1) L5-20R
Line-Interactive UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 2200VA 1600W, Tower, 120V
Condition: New batteries, refurbished UPS
Part Number: SMART2200SLT
Maximum output: 1600W / 2200VA
Typical backup time at half load: 13 minutes (800 Watts)
Typical backup time at full load: 5 minutes (1600 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 2200VA 1600W Tower 120V SMART2200SLT Manual
SMART2200SLT - Tripp Lite SmartPro Specifications:
Input:
|
Rated input current (Maximum Load) |
15A |
||
|
Nominal Input Voltage(s) Supported |
120V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
20A |
||
|
UPS Input Cord Length (ft.) |
10 |
||
|
UPS Input Cord Length (m) |
3.1 |
||
|
Recommended Electrical Service |
20A 120V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
2200 |
||||
|
Output Capacity (kVA) |
2.2 |
||||
|
Output Watt Capacity (Watts) |
1600 |
||||
|
Output kW Capacity (kW) |
1.6 |
||||
|
Power Factor |
0.7 |
||||
|
Nominal Voltage Details |
120v nominal output in battery mode |
||||
|
Frequency Compatibility |
60 Hz |
||||
|
Output Voltage Regulation (Line Mode) |
-18% / +8% |
||||
|
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||||
|
Output AC Waveform (AC Mode) |
Sine wave |
||||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||
|
Nominal Output Voltage(s) Supported |
110V; 115V; 120V |
||||
|
Output Receptacles |
|
||||
|
Individually Controllable Load Banks |
No |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
5 min. (1600w) |
|
Half Load Runtime (min.) |
13 min. (800w) |
|
Expandable Runtime |
No |
|
DC System Voltage (VDC) |
48 |
|
Battery Recharge Rate (Included Batteries) |
Less than 4.5 hours from 10% to 90% (typical, full load discharge) |
|
Battery Access |
Battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC54 |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83V to overvoltages to 145V |
|
Overvoltage Correction |
Input voltages between 127 and 145 are reduced by 12%; Voltage setpoints subject to ±5% tolerance |
|
Undervoltage Correction |
Input voltages between 96 and 108V are boosted by 12%; Voltage setpoints subject to ±5% tolerance |
|
Severe Undervoltage Correction |
Input voltages between 83 and 95V are boosted by 24%; Voltage setpoints subject to ±5% tolerance |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
|
Audible Alarm |
Audible alarm indicates power failure and overload conditions |
|
LED Indicators |
9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
570 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Tower
|
|
Cooling Method |
Fan
|
|
Installation Form Factors Supported with Included Accessories |
Tower
|
|
Primary UPS Depth (mm) |
318 |
|
Primary UPS Height (mm) |
267 |
|
Primary UPS Width (mm) |
226 |
|
Shipping Dimensions (hwd / cm) |
39.12 x 36.32 x 43.69 |
|
Shipping Dimensions (hwd / in.) |
15.40 x 14.30 x 17.20 |
|
Shipping Weight (kg) |
31.34 |
|
Shipping Weight (lbs.) |
69.10 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
26.67 x 22.61 x 31.75 |
|
UPS Power Module Dimensions (hwd, in.) |
10.5 x 8.9 x 12.5 |
|
UPS Power Module Weight (kg) |
25.85 |
|
UPS Power Module Weight (lbs.) |
57 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
287 |
|
Battery Mode BTU / Hr. (Full Load) |
889 |
|
AC Mode Efficiency Rating (100% Load) |
95% |
|
Audible Noise |
Audible Noise < 50 dBA at Front Side 1 Meter |
Communications:
|
Network Management Cards |
SNMPWEBCARD ; WEBCARDLX ; RELAYIOCARD |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |